Search NASASearch

Engineering topics

Li, M. J.

Publications and source records attributed to Li, M. J..

Electrostatic Microshutter Arrays

Based on the Microshutter Array (MSA) subsystems developed at NASA Goddard Space Flight Center (GSFC) for the James Webb Space Telescope (JWST), Next Generation Microshutter Array (NGMSA) has been developed to be used as multi-object selectors for future telescopes in space applications. Microshutter arrays function as transmission devices. Selected shutters fully open at 90 degrees permitting income light going through, while the rest of shutters keep closed. The programmable microshutter open and close make the device perform as a multi object selector that can be used on space telescopes. Utilizing a multi object selector, the telescope efficiency can be increased to 100 times or more. Like JWST MSAs, NGMSA features torsion hinges, light shields, front and back electrodes for shutter actuation, latch, and closing. The difference is that JWST MSA utilized the magnetic actuation while NGMSA the electrostatic actuation.

Micro-electro-mechanical-system (MEMS)

Very High Resolution Solar X-ray Imaging Using Diffractive Optics

This paper describes the development of X-ray diffractive optics for imaging solar flares with better than 0.1 arcsec angular resolution. X-ray images with this resolution of the greater than or equal to 10 MK plasma in solar active regions and solar flares would allow the cross-sectional area of magnetic loops to be resolved and the coronal flare energy release region itself to be probed. The objective of this work is to obtain X-ray images in the iron-line complex at 6.7 keV observed during solar flares with an angular resolution as fine as 0.1 arcsec - over an order of magnitude finer than is now possible. This line emission is from highly ionized iron atoms, primarily Fe xxv, in the hottest flare plasma at temperatures in excess of approximately equal to 10 MK. It provides information on the flare morphology, the iron abundance, and the distribution of the hot plasma. Studying how this plasma is heated to such high temperatures in such short times during solar flares is of critical importance in understanding these powerful transient events, one of the major objectives of solar physics.We describe the design, fabrication, and testing of phase zone plate X-ray lenses with focal lengths of approximately equal to 100 m at these energies that would be capable of achieving these objectives. We show how such lenses could be included on a two-spacecraft formation-flying mission with the lenses on the spacecraft closest to the Sun and an X-ray imaging array on the second spacecraft in the focal plane approximately equal to 100 m away. High resolution X-ray images could be obtained when the two spacecraft are aligned with the region of interest on the Sun. Requirements and constraints for the control of the two spacecraft are discussed together with the overall feasibility of such a formation-flying mission.

Dennis, B. R.

Development and Operation of the Microshutter Array System

The microshutter array (MSA) is a key component in the James Webb Space Telescope Near Infrared Spectrometer (NIRSpec) instrument. The James Webb Space Telescope is the next generation of a space-borne astronomy platform that is scheduled to be launched in 2013. However, in order to effectively operate the array and meet the severe operational requirements associated with a space flight mission has placed enormous constraints on the microshutter array subsystem. This paper will present an overview and description of the entire microshutter subsystem including the microshutter array, the hybridized array assembly, the integrated CMOS electronics, mechanical mounting module and the test methodology and performance of the fully assembled microshutter subsystem. The NIRSpec is a European Space Agency (ESA) instrument requiring four fully assembled microshutter arrays, or quads, which are independently addressed to allow for the imaging of selected celestial objects onto the two 4 mega pixel IR detectors. Each microshutter array must have no more than approx.8 shutters which are failed in the open mode (depending on how many are failed closed) out of the 62,415 (365x171) total number of shutters per array. The driving science requirement is to be able to select up to 100 objects at a time to be spectrally imaged at the focal plane. The spectrum is dispersed in the direction of the 171 shutters so if there is an unwanted open shutter in that row the light from an object passing through that failed open shutter will corrupt the spectrum from the intended object.

Jhabvala, M. D.

The Development of Microshutters for the Near Infrared Spectrograph on the James Webb Space Telescope

One of the James Webb Space Telescope's (JWST) primary science goals is to characterize the epoch of galaxy formation in the universe and observe the first galaxies and clusters of galaxies. This goal requires multi-band imaging and spectroscopic data in the near infrared portion of the spectrum for large numbers of very faint galaxies. Because such objects are sparse on the sky at the JWST resolution, a multi-object spectrograph is necessary to efficiently carry out the required observations. We have developed a fully programmable microshutter array that will be used as the field selector for the Near Infrared Spectrograph (NIRSpec) on JWST. This device allows slits to be opened at the locations of selected galaxies in the field of view while blocking other unwanted light from the sky background and bright sources. In practice, greater than 100 objects within the field of view will be observed simultaneously. In this paper, we describe the microshutter arrays, their development, fabrication, testing, and progress toward delivery of flight qualified devices to the NIRSpec instrument team in 2008.

Silverberg, Robert F.

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.

Cryogenic Characterization and Testing of Magnetically-Actuated Microshutter Arrays for the James Webb Space Telescope

Two-dimensional MEMS microshutter arrays (MSA) have been fabricated at the NASA Goddard Space Flight Center (GSFC) for the James Webb Space Telescope (JWST) to enable cryogenic (approximately 35 K) spectrographic astronomy measurements in the near-infrared region. Functioning as a focal plane object selection device, the MSA is a 2-D programmable aperture mask with fine resolution, high efficiency and high contrast. The MSA are close- packed silicon nitride shutters (cell size of 100 x 200 microns) patterned with a torsion flexure to allow opening to 90 degrees. A layer of magnetic material is deposited onto each shutter to permit magnetic actuation. Two electrodes are deposited, one onto each shutter and another onto the support structure side-wall, permitting electrostatic latching and 2-D addressing. New techniques were developed to test MSA under mission-similar conditions (8 K less than or equal to T less than 300K). The magnetic rotisserie has proven to be an excellent tool for rapid characterization of MSA. Tests conducted with the magnetic rotisserie method include accelerated cryogenic lifetesting of unpackaged 128 x 64 MSA and parallel measurement of the magneto-mechanical stiffness of shutters in pathfinder test samples containing multiple MSA designs. Lifetest results indicate a logarithmic failure rate out to approximately 10(exp 6) shutter actuations. These results have increased our understanding of failure mechanisms and provide a means to predict the overall reliability of MSA devices.

King, T. T.

Fabrication of MEMS-Based Microshutter Arrays for Optical Transmission Selection

A MEMS-based programmable aperture mask is under development at the NASA Goddard Space Flight Center. Termed the Microshutter (u-shutter) Array, the device will be used to control the transmission of light, with both high efficiency and contrast, to a multi-object spectrometer on the James Webb Space Telescope. Fabrication of the p-shutter array employs several novel designs and processing techniques. The current generation of micro-shutters consists of 128x64 pixel arrays with unit cell dimensions of 100x200 microns. Shutters are patterned in silicon nitride and sit on a 100 micron silicon frame that is DRIE etched below each shutter. The front and back sides of the device are shown. A magnetic cobalt-iron alloy patterned on top of the shutter allows it to be actuated 90 degrees out-of-plane, into the frame, by an external magnetic field. An electrode on the shutter and a vertical electrode on the sidewall of the frame, approximately 90pm deep, allow them to be electrostatically latched in their rotated position. The vertical electrode is deposited and patterned on the backside of the frame in a single step using a directionally controlled evaporation. Individual addressing of shutters for electrostatic latching is accomplished via a crosspoint addressing scheme, with no on-chip active components. A portion of an array with shutters in the open, latched, and closed positions is shown. Light loss at shutter edges is minimized by an overhanging aluminum light-shield that is anchored to the frame. A photoresist sacrificial layer is used to raise the light-shield up and over the 2 micron gap that surrounds each pixel. After completion, arrays are subjected to life cycle, environmental and optical testing. Fabricated devices have survived 10(exp 6) actuation cycles at both room and cryogenic temperatures and a 14g rms launch-simulation test. Optical testing has shown contrast measurements between open and closed shutters up to 10000:1.

Lynch, Bernard A.

Antenna-Coupled Superconducting Tunnel Junctions with Single-Electron Transistor Readout for Detection of Sub-mm Radiation

Antenna-coupled superconducting tunnel junction detectors have the potential for photon-counting sensitivity at sub-mm wavelengths. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation using Superconducting Tunnel Junctions with Radio-Frequency Single-Electron Transistors

The science drivers for the SPIRIT/SPECS missions demand sensitive, fast, compact, low-power, large-format detector arrays for high resolution imaging and spectroscopy in the far infrared and submillimeter. Detector arrays with 10,000 pixels and sensitivity less than 10(exp 20)-20 W/Hz(exp 20)0.5 are needed. Antenna-coupled superconducting tunnel junction detectors with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique when forming arrays. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.

Fabrication of Tunnel Junctions For Direct Detector Arrays With Single-Electron Transistor Readout Using Electron-Beam Lithography

This paper will describe the fabrication of small aluminum tunnel junctions for applications in astronomy. Antenna-coupled superconducting tunnel junctions with integrated single-electron transistor readout have the potential for photon-counting sensitivity at sub-millimeter wavelengths. The junctions for the detector and single-electron transistor can be made with electron-beam lithography and a standard self-aligned double-angle deposition process. However, high yield and uniformity of the junctions is required for large-format detector arrays. This paper will describe how measurement and modification of the sensitivity ratio in the resist bilayer was used to greatly improve the reliability of forming devices with uniform, sub-micron size, low-leakage junctions.