Fugitive methane detection using open-path stand-off chirped laser dispersion spectroscopy

We report an open-path chirped laser dispersion spectrometer capable of detecting the atmospheric methane concentration above the background using both specular and diffusive reflective surfaces via two distinct operation modes in a stand-off detection configuration. The system is integrated with simultaneous ranging functionality, which enables average concentration measurements for varying optical pathlengths. The system was first tested for accuracy and characterized to achieve sensitivity of 2.9 p p m - m / H z 1 / 2 and pathlength precision of 0.2 m / H z 1 / 2 with a controlled release of methane outside the laboratory. The instrument was subsequently field-deployed in the proximity of a natural gas compressor station for fugitive methane detection. The instrument successfully detected methane plumes and narrowed down the location of the plume through multi-path measurement. The field measurements were verified by a co-located reference mobile methane sensor.

Chen, Yifeng↗

Remote methane sensor for emissions from pipelines and compressor stations using chirped-laser dispersion spectroscopy

Leak rates of methane (CH 4 ) from the natural gas supply chain result in lost profit from unsold product, public safety and property concerns due to potential explosion hazards, and a potentially large source of economic damages from legal liabilities. Yet large measurement challenges exist in identifying and quantifying CH 4 leak rates along the vast number and type of components in the natural gas supply chain. This is particularly true of the “midstream” components involved in the gathering, processing, compression, transmission, and storage of natural gas. This project developed and deployed new advances in chirped laser dispersion spectroscopy (CLaDS) to detect methane leaks from pipelines, compressor stations, and other midstream infrastructure from a remote position (standoff detection). The system was deployed from a van to measure fugitive methane leaks from a local compressor station as a proof-of-concept. The technique was validated through mobile laboratory measurements with in-situ sensors as well as controlled releases of methane. The system also mapped a plume from a controlled release of methane by tracking a small unmanned aerial system (sUAS) that carried a corner cube retroreflector which reflected the beam back to the instrument. The drone-based system quantified a leak rate to within 30% of the actual rate and localized the emission location within 5 m of the actual release location at standoff distances of 25-45 m. This sUAS-reflector tracking approach has benefits for mapping leak locations remotely using small drones flying around a facility. Benefits of a commercial sensor with these capabilities include reductions of leaks for pipeline operators (more profit), earlier detection of leaks to avoid catastrophic explosion hazards for public health and to mitigate property damage, and reduced methane emissions to the atmosphere (improving air quality).

03 NATURAL GAS↗