Search NASA⌕ Search

Engineering topics

Li, Qiliang

Publications and source records attributed to Li, Qiliang.

Intelligent Electrochemical Sensors for Precise Identification of Volatile Organic Compounds Enabled by Neural Network Analysis

The volatile organic compounds (VOCs) in a wide spectrum of categories were identified as biomarkers in aquatic environments, playing an important role in marine and freshwater ecology and global atmospheric chemistry. VOCs released from biofuel have also attracted increasing attention. Although the importance has been recognized, the portable detection and analysis methods of VOC in aquatic systems have not yet been well developed and understood. Here, in this work, we innovatively proposed an intelligent electrochemical sensing approach to classify and quantify VOCs in solution. Utilizing the cyclic voltammetry (CV) method with an ionic liquid (IL)-based electrolyte, we analyzed 50 μL samples of various VOC analytes, including acetic acid (AC), acetone, dimethylformamide (DMF), dimethyl sulfoxide (DMSO), ethanol, formaldehyde, formic acid, methanol, methyl formate (MF), toluene, and a formaldehyde-methanol mixture, along with deionized water (DI water). The generated voltammograms were subsequently analyzed using our uniquely designed and optimized 1-D convolutional neural network (1D-CNN). This deep-learning algorithm achieved a 99.09% accuracy in VOC classification validated through fivefold cross-validation and demonstrated an impressive 94.4% test accuracy for methanol detection within a 10 μL error range. For quantification, the system accurately categorized methanol volumes ranging from 0 to 50 μL in 10 μL increments, achieving a 98.18% accuracy. A notable linear correlation (R2 = 95.56%) was found between max current density at the oxidation peak and methanol volume, with the limit of detection (LOD) at 9.3 μL. Such a sensing method exhibits potential for portability, high accuracy, and generalization in the classification and quantification, ultimately reshaping the realm of VOC analysis in solution.

42 ENGINEERING↗

Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods

The detection of volatile organic compounds (VOCs) is an important topic for environmental safety and public health. However, the current commercial VOC detectors suffer from cross-sensitivity and low reproducibility. In this work, we present species-selective detection for VOCs using an electrochemical cell based on ionic liquid (IL) electrolytes with features of high selectivity and reliability. The voltammograms measured with the IL-based electrolyte absorbing different VOCs exhibited species-selective features that were extracted and classified by linear discriminant analysis (LDA). The detection system could identify as many as four types of VOCs, including methanol, ethanol, acetone, formaldehyde, and additional water. A mixture of methanol and formaldehyde was detected as well. The sample required for the VOCs classification system was 50 μL, or 1.164 mmol, on average. The response time for each VOC measurement is as fast as 24 s. The volume of VOCs such as formaldehyde in solution could also be quantified by LDA and electrochemical impedance spectroscopy techniques, respectively. The system showed a tunable detection range for 1.6 and 16% (w/v) CH 2 O solution by adjusting the composition of the electrolyte. The limit of detection was as low as 1 μL. For the 1.6% CH 2 O solution, the linearity calibration range was determined to be from 5.30 to 53.00 μmol with a limit of detection at 0.53 μmol. The mechanisms for VOCs determination and quantification are also thoroughly discussed. Finally, it is expected that this work could provide a new insight into the concept of electrochemical detection of VOCs with machine learning analysis and be applied to both VOCs gas monitoring and fluid detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superior photodynamic effect of single-walled carbon nanotubes in aprotic media: a kinetic study

It has been confirmed that single-walled carbon nanotubes (SWCNTs) could generate reactive oxygen species in aprotic media by utilizing photon energy. However, the impact of photon irradiation on SWCNTs and the kinetics of the generation process in aprotic media are still unclear, which significantly limits the yield performance. In this work, the kinetics for photodynamic effects has been investigated by performing characterizations on ultraviolet-treated SWCNTs using Raman spectroscopy, conductive atomic force microscope (in-situ), kelvin probe force microscope, and X-ray photoelectron spectroscopy. It is found that ultraviolet-treated SWCNTs are observed to have more defects, lower conductivity, and less surface charge after energy conversion. Starting from the fundamental intrinsic properties of SWCNTs, the kinetics and formation of these changes are thoroughly discussed. It turns out that the dispersion, chirality, and structural integrity of SWCNTs are important for achieving high-performance photodynamic effects, which are validated using several different SWCNTs as well as other carbon nanomaterials. A type of (6,5) s-SWCNTs exhibited the highest energy efficiency among a variety of other carbon nanomaterials. The yield rate is 2.15 mM/h, and the energy consumption is determined to be 2.79 W∙h/mM. This work is expected to help dramatically boost the energy efficiency of the photodynamic effect in aprotic media and pave the way for designing high-performance carbon nanomaterial-based photoinduced devices.

36 MATERIALS SCIENCE↗