Low-surface-area hard carbon anode for Na-ion batteries via graphene oxide as a dehydration agent
Na-ion batteries are emerging as one of the most promising energy storage technologies, particularly for grid-level applications. Among anode candidate materials, hard carbon is very attractive due to its high capacity and low cost. However, hard carbon anodes often suffer a low first-cycle Coulombic efficiency and fast capacity fading. In this study, we discover that doping graphene oxide into sucrose, the precursor for hard carbon, can effectively reduce the specific surface area of hard carbon to as low as 5.4 m²/g. We further reveal that such doping can effectively prevent foaming during caramelization of sucrose and extend the pyrolysis burn-off of sucrose caramel over a wider temperature range. Thus, the obtained low-surface-area hard carbon greatly improves the first-cycle Coulombic efficiency from 74% to 83% and delivers a very stable cyclic life with 95% of capacity retention after 200 cycles.
IRAK4 Dimerization and trans-Autophosphorylation Are Induced by Myddosome Assembly
Abstract not provided
SU-F-BRD-04: Development of a Secondary MU Calculation Tool for An Integrated MR-LINAC
Purpose: To develop a fast secondary MU calculation tool for an integrated MR-Linac, an emerging technology for delivering image-guided on-line adaptive therapy. Methods: A software tool was developed to implement a modified Clarkson integration algorithm for point-dose calculation, considering the dosimtric effect of a magnetic field. A research planning system, considering the presence of a perpendicular 1.5 T magnetic field, was used to extract the beam data (e.g., depth doses and beam profiles) required for the MU calculation in homogeneous phantom of 60×60×40 cm3 for a prototype of MR-Linac integrating a 1.5 T MR scanner with 6MV photon beams. These dosimetric data may be replaced with those to be collected during the commissioning measurement of the MR-Linac. Results: The presence of the magnetic field resulted in noticeable changes including (1) shifts in beam profiles for small fields (< 2×2 cm2), and (2) changes in central-axis doses when one of field edges is < 2 cm away from the central axis. For example, the maximum change in central-axis dose was up to 8% for one of the field borders with a distance away from the central axis of <1 cm. These changes are relevant for the MU calculation particularly for IMRT and VMAT, where most of segments are small. These magnetic field affected beam profiles and depth doses were included in the software tool. The MU calculations from the software tool for selective representative plans were found to agree with those from the research planning system within 10%. Conclusion: The presence of a perpendicular magnetic field results in noticeable changes in beam profiles and depth doses for small fields. These changes are included in the secondary MU calc{sup 33}u{sup 3}lation to be used as a redundancy check for an integrated MR-Linac.
MO-C-17A-06: Online Adaptive Re-Planning to Account for Independent Motions Between Multiple Targets During Radiotherapy of Lung Cancer
Purpose: To quantify interfractional independent motions between multiple targets in radiotherapy (RT) of lung cancer, and to study the dosimetric benefits of an online adaptive replanning method to account for these variations. Methods: Ninety five diagnostic-quality daily CTs acquired for 9 lung cancer patients treated with IGRT using an in-room CT (CTVision, Siemens) were analyzed. On each daily CT set, contours of the targets (GTV, CTV, or involved nodes) and organs at risk were generated by populating the planning contours using an auto-segmentation tool (ABAS, Elekta) with manual editing. For each patient, an IMRT plan was generated based on the planning CT with a prescription dose of 60 Gy in 2Gy fractions. Three plans were generated and compared for each daily CT set: an IGRT (repositioning) plan by copying the original plan with the required shifts, an online adaptive plan by rapidly modifying the aperture shapes and segment weights of the original plan to conform to the daily anatomy, and a new fully re-optimized plan based on the daily CT using a planning system (Panther, Prowess). Results: The daily deviations of the distance between centers of masses of the targets from the plans varied daily from -10 to 8 mm with an average −0.9±4.1 mm (one standard deviation). The average CTV V100 are 99.0±0.7%, 97.9±2.8%, 99.0±0.6%, and 99.1±0.6%, and the lung V20 Gy 928±332 cc, 944±315 cc, 917±300 cc, and 891±295 cc for the original, repositioning, adaptive, and re-optimized plans, respectively. Wilcoxon signed-rank tests show that the adaptive plans are statistically significantly better than the repositioning plans and comparable with the reoptimized plans. Conclusion: There exist unpredictable, interfractional, relative volume changes and independent motions between multiple targets during lung cancer RT which cannot be accounted for by the current IGRT repositioning but can be corrected by the online adaptive replanning method.
MO-E-17A-06: Organ Dose in Abdomen-Pelvis CT: Does TG 111 Equilibrium Dose Concept Better Accounts for KVp Dependence Than Conventional CTDI?
Purpose: In CT imaging, a desirable quality assurance (QA) dose quantity should account for the dose variability across scan parameters and scanner models. Recently, AAPM TG 111 proposed to use equilibrium dose-pitch product, in place of CT dose index (CTDI100), for scan modes involving table translation. The purpose of this work is to investigate whether this new concept better accounts for the kVp dependence of organ dose than the conventional CTDI concept. Methods: The adult reference female extended cardiac-torso (XCAT) phantom was used for this study. A Monte Carlo program developed and validated for a 128-slice CT system (Definition Flash, Siemens Healthcare) was used to simulate organ dose for abdomenpelvis scans at five tube voltages (70, 80, 100, 120, 140 kVp) with a pitch of 0.8 and a detector configuration of 2x64x0.6 mm. The same Monte Carlo program was used to simulate CTDI100 and equilibrium dose-pitch product. For both metrics, the central and peripheral values were used together with helical pitch to calculate a volume-weighted average, i.e., CTDIvol and (Deq)vol, respectively. Results: While other scan parameters were kept constant, organ dose depended strongly on kVp; the coefficient of variation (COV) across the five kVp values ranged between 70–75% for liver, spleen, stomach, pancreas, kidneys, colon, small intestine, bladder, and ovaries, all of which were inside the primary radiation beam. One-way analysis of variance (ANOVA) for the effect of kVp was highly significant (p=3e−30). When organ dose was normalized by CTDIvol, the COV across the five kVp values reduced to 7–16%. The effect of kVp was still highly significant (p=4e−4). When organ dose was normalized by (Deq)vol, the COV further reduced to 4−12%. The effect of kVp was borderline significant (p=0.04). Conclusion: In abdomen-pelvis CT, TG 111 equilibrium dose concept better accounts for kVp dependence than the conventional CTDI. This work is supported by a faculty startup fund from the Cleveland State University.
MO-G-BRE-04: Automatic Verification of Daily Treatment Deliveries and Generation of Daily Treatment Reports for a MR Image-Guided Treatment Machine
Purpose: Two aims of this work were to develop a method to automatically verify treatment delivery accuracy immediately after patient treatment and to develop a comprehensive daily treatment report to provide all required information for daily MR-IGRT review. Methods: After systematically analyzing the requirements for treatment delivery verification and understanding the available information from a novel MR-IGRT treatment machine, we designed a method to use 1) treatment plan files, 2) delivery log files, and 3) dosimetric calibration information to verify the accuracy and completeness of daily treatment deliveries. The method verifies the correctness of delivered treatment plans and beams, beam segments, and for each segment, the beam-on time and MLC leaf positions. Composite primary fluence maps are calculated from the MLC leaf positions and the beam-on time. Error statistics are calculated on the fluence difference maps between the plan and the delivery. We also designed the daily treatment delivery report by including all required information for MR-IGRT and physics weekly review - the plan and treatment fraction information, dose verification information, daily patient setup screen captures, and the treatment delivery verification results. Results: The parameters in the log files (e.g. MLC positions) were independently verified and deemed accurate and trustable. A computer program was developed to implement the automatic delivery verification and daily report generation. The program was tested and clinically commissioned with sufficient IMRT and 3D treatment delivery data. The final version has been integrated into a commercial MR-IGRT treatment delivery system. Conclusion: A method was developed to automatically verify MR-IGRT treatment deliveries and generate daily treatment reports. Already in clinical use since December 2013, the system is able to facilitate delivery error detection, and expedite physician daily IGRT review and physicist weekly chart review.
TU-A-BRD-01: Outcomes of Hypofractionated Treatments - Initial Results of the WGSBRT
Stereotactic Body Radiation Therapy (SBRT) has emerged in recent decades as a treatment paradigm that is becoming increasingly important in clinical practice. Clinical outcomes data are rapidly accumulating. Although published relations between outcomes and dose distributions are still sparse, the field has progressed to the point where evidence-based normal tissue dose-volume constraints, prescription strategies, and Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) models can be developed. The Working Group on SBRT (WGSBRT), under the Biological Effects Subcommittee of AAPM, is a group of physicists and physicians working in the area of SBRT. It is currently performing critical literature reviews to extract and synthesize usable data and to develop guidelines and models to aid with safe and effective treatment. The group is investigating clinically relevant findings from SBRT in six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session of AAPM 2014, interim results are presented on TCP for lung and liver, NTCP for thoracic organs, and radiobiological foundations:• Lung TCP: Detailed modeling of TCP data from 118 published studies on early stage lung SBRT investigates dose response and hypothesized mechanisms to explain the improved outcomes of SBRT. This is presented from the perspective of a physicist, a physician, and a radiobiologist.• Liver TCP: For primary and metastatic liver tumors, individual patient data were extracted from published reports to examine the effects of biologically effective dose on local control.• Thoracic NTCP: Clinically significant SBRT toxicity of lung, rib / chest wall and other structures are evaluated and compared among published clinical data, in terms of risk, risk factors, and safe practice.• Improving the clinical utility of published toxicity reports from SBRT and Hypofractionated treatments. What do we want, and how do we get it? Methods and problems of synthesizing data from published reports. Learning Objectives: Common SBRT fractionation schemes and current evidence for efficacy. Evidence for normal tissue tolerances in hypofractionated treatments. Clinically relevant radiobiological effects at large fraction sizes.
TU-A-9A-06: Semi-Automatic Segmentation of Skin Cancer in High-Frequency Ultrasound Images: Initial Comparison with Histology
Purpose: In skin-cancer radiotherapy, the assessment of skin lesion is challenging, particularly with important features such as the depth and width hard to determine. The aim of this study is to develop interative segmentation method to delineate tumor boundary using high-frequency ultrasound images and to correlate the segmentation results with the histopathological tumor dimensions. Methods: We analyzed 6 patients who comprised a total of 10 skin lesions involving the face, scalp, and hand. The patient’s various skin lesions were scanned using a high-frequency ultrasound system (Episcan, LONGPORT, INC., PA, U.S.A), with a 30-MHz single-element transducer. The lateral resolution was 14.6 micron and the axial resolution was 3.85 micron for the ultrasound image. Semiautomatic image segmentation was performed to extract the cancer region, using a robust statistics driven active contour algorithm. The corresponding histology images were also obtained after tumor resection and served as the reference standards in this study. Results: Eight out of the 10 lesions are successfully segmented. The ultrasound tumor delineation correlates well with the histology assessment, in all the measurements such as depth, size, and shape. The depths measured by the ultrasound have an average of 9.3% difference comparing with that in the histology images. The remaining 2 cases suffered from the situation of mismatching between pathology and ultrasound images. Conclusion: High-frequency ultrasound is a noninvasive, accurate and easy-accessible modality to image skin cancer. Our segmentation method, combined with high-frequency ultrasound technology, provides a promising tool to estimate the extent of the tumor to guide the radiotherapy procedure and monitor treatment response.
TU-C-12A-07: Characterization of Longitudinal Reproducibility of Quantitative Diffusion Imaging Data Acquired with Four Different Protocols Using a Phantom
Purpose: To characterize and compare the longitudinal reproducibility of diffusion imaging data acquired with four different protocols using a phantom. Methods: The Diffusive Quantitative Imaging Phantom (DQIP) was constructed using fifteen cylindrical compartments within a larger compartment, filled with deionized water doped with CuSO4 and NaCl. The smaller compartments contained arrays of hexagonal or cylindrical glass capillaries of varying inner diameters, for differing restraint of water diffusion. The sensitivity of diffusion imaging metrics to signal-to-noise ratio (SNR) was probed by doping compartments with differing ratios of deuterium oxide to H2O. A cork phantom enclosure was constructed to increase thermal stability during scanning and a cork holder was made to reproduce scanner positioning. Four different protocols of DWI (diffusion weighted imaging) and DTI (Diffusion tensor imaging) imaging were assembled on a GE Excite HDx 3.0T MRI scanner to collect imaging data over 9-10 days. Data was processed with in-house software created in Matlab to obtain fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values. Results: All DTI and DWI sequences showed good longitudinal stability of mean FA and ADC values per compartment, exhibiting low standard deviation ∼9%. A t-test was performed to compare mean FA values from the DTI clinical protocol to those of the DTI special protocol, indicating significantly different values in the majority of compartments. ANOVA performed on ADC values for all DTI and DWI sequences also showed significantly different values in a majority of compartments. Conclusion: This work has the potential for quantifying systemic variations between diffusion imaging sequences from different platforms. Characterization of DWI and DTI performance were done over four sequences with predictable results. This data suggests that the DQIP phantom may be a reliable method of monitoring day-to-day and scan-to-scan variation in diffusion imaging sequences from different platforms. Schott Glass North America and The Phantom Laboratory have donated materials and personnel time to this project.
WE-G-17A-09: Novel Magnetic Shielding Design for Inline and Perpendicular Integrated 6 MV Linac and 1.0 T MRI Systems
Purpose: The influence of fringe magnetic fields delivered by magnetic resonance imaging (MRI) on the beam generation and transportation in Linac is still a major challenge for the integration of linear accelerator and MRI (Linac-MRI). In this study, we investigated an optimal magnetic shielding design for Linac-MRI and further characterized the beam trajectory in electron gun. Methods: Both inline and perpendicular configurations were analyzed in this study. The configurations, comprising a Linac-MRI with a 100cm SAD and an open 1.0 T superconductive magnet, were simulated by the 3D finite element method (FEM). The steel shielding around the Linac was included in the 3D model, the thickness of which was varied from 1mm to 20mm, and magnetic field maps were acquired with and without additional shielding. The treatment beam trajectory in electron gun was evaluated using OPERA 3d SCALA with and without shielding cases. Results: When Linac was not shielded, the uniformity of diameter sphere volume (DSV) (30cm) was about 5 parts per million (ppm) and the fringe magnetic fields in electron gun were more than 0.3 T. With shielding, the magnetic fields in electron gun were reduced to less than 0.01 T. For the inline configuration, the radial magnetic fields in the Linac were about 0.02T. A cylinder steel shield used (5mm thick) altered the uniformity of DSV to 1000 ppm. For the perpendicular configuration, the Linac transverse magnetic fields were more than 0.3T, which altered the beam trajectory significantly. A 8mm-thick cylinder steel shield surrounding the Linac was used to compensate the output losses of Linac, which shifted the magnetic fields' uniformity of DSV to 400 ppm. Conclusion: For both configurations, the Linac shielding was used to ensure normal operation of the Linac. The effect of magnetic fields on the uniformity of DSV could be modulated by the shimming technique of the MRI magnet. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.
TH-C-BRE-01: IGART: Fast On-Line Planning for IGART
Cone beam CT IGRT provides on-line anatomical data of the patient at the treatment couch while new hybrid MRI radiotherapy systems promise to provide this data during the actual radiation delivery itself. To exploit these data, and account for tissue rotations, deformations and tumor regression during radiation therapy delivery, fast, on-line IMRT (re)planning is required.On-line IMRT re-planning needs to re-generate a similar patient specific dose distribution as done in the pre-treatment planning but then for the new state of the anatomy. For this the pre-treatment information has to be propagated to the actual treatment. A fast dose engine is required, which may be, in the case of MRI based IGRT, Monte Carlo based in order to account for the magnetic field induced dose effects. Then robust re-planning methods or class solutions should be available that account efficiently for both rigid and non-rigid anatomical changes while preserving the patient specific pre-treatment dose considerations. Preferably this is all fully automatic, but also fast interactive re-planning is an option, especially in hypo-fractionated (boost) radiotherapy. Learning Objectives: Preservation of pre-treatment prescriptions in the on-line IMRT re-planning Fast re-planning techniques and speed limitations for dose engines Pros and cons of interactive versus automatic re-planning.
TH-E-BRE-04: An Online Replanning Algorithm for VMAT
Purpose: To develop a fast replanning algorithm based on segment aperture morphing (SAM) for online replanning of volumetric modulated arc therapy (VMAT) with flattening filtered (FF) and flattening filter free (FFF) beams. Methods: A software tool was developed to interface with a VMAT planning system ((Monaco, Elekta), enabling the output of detailed beam/machine parameters of original VMAT plans generated based on planning CTs for FF or FFF beams. A SAM algorithm, previously developed for fixed-beam IMRT, was modified to allow the algorithm to correct for interfractional variations (e.g., setup error, organ motion and deformation) by morphing apertures based on the geometric relationship between the beam's eye view of the anatomy from the planning CT and that from the daily CT for each control point. The algorithm was tested using daily CTs acquired using an in-room CT during daily IGRT for representative prostate cancer cases along with their planning CTs. The algorithm allows for restricted MLC leaf travel distance between control points of the VMAT delivery to prevent SAM from increasing leaf travel, and therefore treatment delivery time. Results: The VMAT plans adapted to the daily CT by SAM were found to improve the dosimetry relative to the IGRT repositioning plans for both FF and FFF beams. For the adaptive plans, the changes in leaf travel distance between control points were < 1cm for 80% of the control points with no restriction. When restricted to the original plans' maximum travel distance, the dosimetric effect was minimal. The adaptive plans were delivered successfully with similar delivery times as the original plans. The execution of the SAM algorithm was < 10 seconds. Conclusion: The SAM algorithm can quickly generate deliverable online-adaptive VMAT plans based on the anatomy of the day for both FF and FFF beams.
SU-C-16A-04: Dosimetric Validation of a Partially-Shielded Gd-153 Brachytherapy Concept
Purpose: To demonstrate by measurement that using partially shielded Gd-153 sources for rotating-shield brachytherapy (RSBT) is feasible. RSBT is a potentially superior alternative to conventional high-dose-rate brachytherapy and provides the opportunity to dramatically improve tumor dose conformity for the treatment of, for example, prostate cancer. Methods: A custom-built, stainless steel encapsulated 150 mCi Gd-153 capsule with an outer length of 12.8 mm, outer diameter of 2.10 mm, active length of 9.98 mm, and active diameter of 1.53 mm was used. A partially shielded catheter was constructed with a 500 μm platinum shield and a 500 μm aluminum emission window, both with 180° azimuthal coverage. An acrylic phantom was constructed to measure the dose distributions from the shielded catheter in the transverse plane using Gafchromic EBT3 films. Film calibration curves were generated from 50, 70, and 100 kVp x-ray beams with NIST-traceable air kerma values to account for energy variation. Results: The transmission ratios of platinum to aluminum shielding at 1 cm off-axis are 7.5% and 7.6% for Monte Carlo (MCNP5) predicted and experimental results, respectively. The predicted/measured relative dose rates at 1 cm, 2 cm and 3 cm off-axis through the Al window were 100%/92.9%, 28.6%/27.0% and 13.8%/12.7%, respectively. Through the Pt shield, the predicted/measured relative dose rates were 7.5%/7.1%, 3.8%/3.0% and 2.4%/1.7%, respectively. Conclusion: Using partially-shielded Gd-153 sources for RSBT is a promising approach to improving brachytherapy dose distributions. The next step in making Gd-153 based RSBT a reality is developing a Gd-153 source that is small enough such that the source, shield, and catheter all fit within a 16 gauge needle, which has a 1.65 mm diameter. University of Iowa Research Foundation.
7 A resolution in protein two-dimensional-crystal X-ray diffraction at Linac Coherent Light Source
Abstract not provided