Publications and source records attributed to Li, Xianting.

Comparison of multi-stage air treatment process divided by the same temperature and enthalpy difference

The multi-stage air treatment system has been proposed recently, and lower grade chilled/hot water could be used and energy efficiency could be improved. However, it has not been studied which division method of air treatment processes has higher energy efficiency. In this study, the model to calculate the energy consumption of multi-stage air treatment process is introduced, and the effects of two division methods, i.e. multi-stage air treatment process divided by the same temperature difference (ST method) or same enthalpy difference (SE method) between inlet and outlet at each stage, under 9 different air inlet parameters in the 2-stage and 3-stage air treatment processes are analysed and compared. The results show that (1) the system energy consumption of the SE method is generally lower than that of the ST method; (2) there is generally a larger energy consumption reduction rate of SE method when the air relative humidity is 70% compared to relative humidity of 50% and 90%; (3) the difference between ST method and SE method is not great, so both methods can be used for the design of multi-stage treatment system although SE method is normally recommended.

Wang, Wentao↗

A Year-Round Energy-Efficient Fresh Air Handling System with Two-Stage Heat Pumps and Lake Water Pre-Treatment

Supplying fresh air is important for indoor air quality, but the energy consumption to treat fresh air is significant. The main problems in existing fresh air system include: supplying single-temperature water to treat fresh air and not applying natural energy sufficiently restrict the efficiency improvement of cooling and heat sources; unused air handling devices under most operating conditions throughout the year increase the fan energy consumption. Thus, this study proposes an efficient fresh air system that uses lake water to pre-treat fresh air and two-stage heat pumps for further treatment, and the unused air handling devices in the system are bypassed. A fresh air system in northern China is selected as a case to show the annual energy performance of the proposed system, and a comparative analysis is conducted between the proposed system and a traditional system. The results show that the annual energy-savings of the proposed system compared to the traditional system come from fans, and compressors, which are 56.5%, and 31.1%, respectively, with an entire system energy saving of 32.2%. The proposed system can achieve an annual system coefficient of performance (COP) of 5.5. This study provides potential for further improving the energy efficiency in fresh air treatment.

Liang, Chenjiyu↗

Cooling performance of direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling

Providing fresh air to rooms can ensure indoor air quality. The direct expansion fresh air handling units are widely used, and most of them are single-stage treatment units, which are less energy-efficient under variable operating conditions. To overcome the shortcomings of existing systems, a direct expansion system using multiple stages and adjustable heat exchange areas for fresh air handling is proposed in this study. The fresh air is handled by coils stage by stage to achieve high efficiency, and the dampers of the idle coils are opened when some of the coils are working, which results in the performance improvement under partial load conditions. The simulation model is established, and operating conditions at load ratio of 95.70%, 45.38%, 31.76% and 0 are selected as typical operating conditions. The proposed system performances under different conditions are compared with traditional system. The results show that: (1) For four conditions, as the load rate decreases, the proposed system can save energy by 6.2%, 26.1%, 46.5%, and 25.0% compared to the traditional system respectively; (2) The proposed system can bypass the filter when the outdoor air is good, which can further save energy by 1.3%, 1.8%, 3.4%, and 25.9% under four conditions, respectively.

Zha, Fuhai↗

Capacity Design Method for Integrated Convective/Radiant Terminals to Guarantee Overall and Local Environment

To achieve energy efficiency in the operation of heating devices and ensure thermal comfort in indoor environments, the integrated convective/radiant terminals have become an important development direction for heating systems. This study selected a 14 m 2 bedroom hot summer and cold winter region in China as a case study. Computational Fluid Dynamics (CFD) methodology was used to investigate the design of integrated convective/radiant terminals to ensure thermal comfort for both the entire room and partial space. The results indicate that focusing on partial space during the steady-state stage can achieve energy savings of 31.1% compared to guaranteeing the entire room. Additionally, during the start-up stage, there is a significant reduction of convective unit capacity by 17.6% when the start-up time is 15 minutes. These findings provide data support for the design and engineering applications of products of integrated convective/radiant terminals. Besides, the excess convection ratios for the entire room and partial space are specified as 0.69 to 0.80 and 0.73 to 0.83, respectively.

Chi, Junjie↗