Search NASA⌕ Search

Engineering topics

Li, Xiaoliang

Publications and source records attributed to Li, Xiaoliang.

Modelling of the electron cyclotron emission burst from a laboratory tokamak plasma with loss-cone maser instability

The maser instability associated with the loss-cone distribution has been widely invoked to explain the radio bursts observed in the astrophysical plasma environment, such as aurora and corona. In the laboratory plasma of a tokamak, events reminiscent of these radio bursts have also been frequently observed as an electron cyclotron emission (ECE) burst in the microwave range (~2f ce near the last closed flux surface) during transient magnetohydrodynamic events. These bursts have a short duration of ~10 μs and display a radiation spectrum corresponding to a radiation temperature T e,rad of over 30 keV while the edge thermal electron temperature T e is only in the range of 1 keV. Suprathermal electrons can be generated through magnetic reconnection, and a loss-cone distribution can be generated through open stochastic field lines in the magnetic mirror of the near-edge region of a tokamak plasma. Radiation modelling shows that a sharp distribution gradient ∂f/∂v ⊥ > 0 at the loss-cone boundary can cause a negative absorption of ECE radiation through the maser instability. The negative absorption then amplifies the radiation so that the microwave intensity is significantly stronger than the thermal value. The significant T e,rad from the simulations suggests the potential role of the loss-cone maser instability in generating the ECE burst in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The 140 GHz notch filter development for millimeter-wave diagnostics protection on the stellarator Wendelstein 7-X

The notch filter plays a crucial role as a protective component in microwave diagnostics, primarily by addressing issues related to catastrophic interference. Designed for millimeter-wave diagnostics on the stellarator Wendelstein 7-X (W7-X), a WR-6 waveguide-based notch filter has been successfully developed to effectively isolate leakage from auxiliary heating gyrotrons operating at 140 GHz. The filter incorporates cylindrical cavities resonating at 140 GHz for the TE11p mode, with coupling structures that are designed and optimized for high-efficiency coupling. This configuration simplifies fabrication, thereby ensuring high-yield production. Experimental fabrication and in-house characterization confirm the notch filter's exceptional performance, with over 60 dB rejection in the vicinity of 140 GHz and low insertion loss (< 2 dB) above and below the notch frequency across a broad frequency bandwidth (121–138 GHz, 142–163 GHz). Furthermore, the utilization of this high-frequency structure fabrication technology can be applied to millimeter-wave diagnostics on other machines. In addition to the design elements of the notch filter, this paper also provides a detailed discussion of the fabrication process and methodology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Frontier system-on-chip (SoC) technology for microwave diagnostics (invited)

The next generation of fusion reactors, exemplified by projects such as the Demonstration Power Plant following the International Thermonuclear Experimental Reactor, faces the monumental challenge of proving the viability of generating electricity through thermonuclear fusion. This pursuit introduces heightened complexities in diagnostic methodologies, particularly in microwave-based diagnostics. The increased neutron fluence necessitates significant reductions in vessel penetrations and the elimination of internal diagnostics, posing substantial challenges. SoC technology offers a promising solution by enabling the miniaturization, modularization, integration, and enhancing the reliability of microwave systems. After seven years of research, our team successfully pioneered the V- and W-band system-on-chip approach, leading to the development of active transmitters and passive receiver modules applied in practical settings, notably within the DIII-D tokamak project. Arrays of these modules have supported microwave imaging diagnostics. New physics measurement results from the Electron Cyclotron Emission Imaging system on DIII-D provide compelling evidence of improved diagnostics following the adoption of SoC technology. Furthermore, we achieved a breakthrough in developing an F-band SoC, advancing higher frequency capabilities for fusion devices. These achievements represent a significant leap forward in fusion diagnostic technology, marking substantial progress toward establishing reliable and efficient plasma diagnostics for future fusion reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Millimeter-wave high-wavenumber scattering diagnostic developments on EAST and NSTX-U

A pioneering 4-channel, high-k poloidal, millimeter-wave collective scattering system has been successfully developed for the Experimental Advanced Superconducting Tokamak (EAST). Engineered to explore high-k electron density fluctuations, this innovative system deploys a 270 GHz mm-wave probe beam launched from Port K and directed toward Port P (both ports lie on the midplane and are 110° part), where large aperture optics capture radiation across four simultaneous scattering angles. Tailored to measure density fluctuations with a poloidal wavenumber of up to 20 cm -1 , this high-k scattering system underwent rigorous laboratory testing in 2023, and the installation is currently being carried out on EAST. Its primary purpose lies in scrutinizing ion and electron-scale instabilities, such as the electron temperature gradient (ETG) mode, by furnishing measurements of the k θ (poloidal wavenumber) spectrum. This advancement significantly bolsters the capacity to probe high-k electron density fluctuations within the framework of EAST. Finally, beam tracing and data interpretation modules developed for both EAST and NSTX-U high-k scattering diagnostics are described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the electron cyclotron emission radiation signature from suprathermal electrons in a tokamak

An Electron Cyclotron Emission (ECE) modeling code has been developed to model ECE radiation with an arbitrary electron momentum distribution, a small oblique angle, both ordinary (O-mode) and extraordinary polarizations (X-mode), and multiple cyclotron frequency harmonics. The emission and absorption coefficients are calculated using the Poynting theorem from the cold plasma dispersion and the electron–microwave interaction from the full anti-Hermitian tensor. The modeling shows several ECE radiation signatures that can be used to diagnose the population of suprathermal electrons in a tokamak. First, in an n = 2 X-mode (X2) optically thick plasma and oblique ECE view, the modeling shows that only suprathermal electrons, which reside in a finite region of the velocity and space domains, can effectively generate cyclotron emissions to the ECE receiver. The code also finds that the O1 mode is sensitive to suprathermal electrons of both a high v ⊥ and v || , while the X2 mode is dominantly sensitive to suprathermal electrons of a high v ⊥ . Finally, the modeling shows that an oblique ECE system with both X/O polarization and a broad frequency coverage can be used to effectively yield information of the suprathermal electron population in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GaN-based W-band receiver chip development for fusion plasma diagnostics

Millimeter-wave diagnostics have proven effective on various magnetic fusion devices worldwide, yet the formidable challenges posed by the harsh environments of future burning plasma devices, characterized by extreme temperatures, pressures, and radiation levels, remain a significant hurdle. To address these challenges, the utilization of wide bandgap Gallium Nitride (GaN)-based millimeter-wave diagnostics is a most promising solution for fusion reactor safety monitoring and control. A noteworthy W-band GaN-based system-on-chip receiver has been the demonstrated by employing HRL T3 40 nm GaN technology. This receiver chip, compactly designed with dimensions of 3 × 5 mm 2 , incorporates essential components such as the 75–110 GHz RF Low-Noise Amplifier (LNA), mixer, Intermediate Frequency (IF) amplifier, and Local Oscillator (LO) chain. This receiver chip will be packaged as a millimeter-wave receiver module and applied on the DIII-D National Fusion Facility, for fusion plasma edge shape monitoring for operational safety and dangerous disruption prediction. The laboratory measurement results have demonstrated suitable performance. Furthermore, this advancement is pivotal for accurate analysis of plasma behavior in the extreme conditions of burning plasma devices, driving progress in fusion research and technology.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a 140 GHz waveguide notch filter for millimeter-wave receiver module protection in fusion plasma diagnostics

A carefully designed waveguide-based millimeter-wave notch filter, operating at 140 GHz, safeguards plasma diagnostic instruments from gyrotron leakage. Here, utilizing cylindrical cavity resonators with aperture coupling, the filter efficiently resonates 140 GHz wave-power into the TE 11p mode, optimizing various geometrical parameters for practical fabrication and high-yield production. Thorough thermal analysis ensures its ability to handle power. The filter achieves outstanding performance with over 90 dB rejection at 140 GHz while providing low insertion loss over the passband (110–138 GHz), which is ideally suited for system-on-chip approach F-band diagnostic system applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reflection Optical Imaging to Study Oxygen Evolution Reactions

Discovery of high-efficiency water-splitting catalysts is critical for clean hydrogen fuel generation. Quantitative and reliable chemical imaging methods can play a crucial role in providing critical catalyst efficiency information for materials development and screening. Here, we developed a reflection optical imaging method to map the performance of transition metal oxide catalysts for oxygen evolution reaction (OER). The generated high concentration of oxygen in the electrolyte will decrease the refractive index of the solutions near the electrode and change the reflectivity of optical images. We successfully imaged and measured the OER on cobalt oxide, and the localized current density and overpotential distribution maps have been extracted. The oxidation and reduction of cobalt oxide can be imaged with our reflection optical imaging method as well. These maps showed that the catalytic activities are quite different at different locations, and some regions showed much higher activities. This is due to the non-uniformity created by the catalyst synthesis process and demonstrates the importance of using the optical imaging method to map the localized catalytic efficiency. In addition, the NiFe alloy’s OER catalytic activities have been studied as well. The proposed reflection optical imaging method could find many applications in catalyst activity measurement and screening.

Electrochemistry↗

Probe the Localized Electrochemical Environment Effects and Electrode Reaction Dynamics for Metal Batteries using In Situ 3D Microscopy

Uncontrollable dendrite growth is closely related to non-uniform reaction environments. However, there is a lack of understanding and analysis methods to probe the localized electrochemical environment (LEE). Here the effects of the LEE are investigated, including localized ion concentrations, current density, and electric potential, on metal plating/stripping dynamics and dendrite minimization. A novel in situ 3D microscopy technique is developed to image the morphology dynamics and deposition rate of Zn plating/stripping processes on 3D Zn–Mn anodes. Using the in situ 3D microscope, the electrode morphology changes during the reactions are directly imaged and Zn deposition rate maps at different time points are obtained. It is found that reaction kinetics are highly correlated to LEE and electrode morphology. To further quantify the LEE effects, the digital twin technique is employed that allows the accurate calculation of the electrochemical environments, such as localized ion concentrations, current density, and electric potential, which cannot be directly measured from experiments. We found that the curvature of the 3D electrode surface determines the LEE and significantly influences reaction kinetics. This provides a new strategy to minimize the dendrite formation by designing and optimizing the 3D geometry of the electrode to control the LEE.

36 MATERIALS SCIENCE↗

Effects of fiber dosage, loading orientation and stress on frequency response of enhanced Carbon Nano-Fiber Aggregates

Nanomaterial additives have been broadly used in cement and concrete-based sensors to measure the stress and strain in the structure. Most of the studies focused on measuring the resistivity of sensors with Direct Current (DC) or relatively low-frequency. Here in this work, the impedance responses of enhanced Carbon Nano-Fiber Aggregates (CNFAs) at different frequencies are rigorously studied and utilized as a tool for real-time structural health monitoring (SHM). The CNFA impedance measurements at different measurement frequencies provide an extra dimension (frequency dimension) to allow the characterization of different phenomena and multimodal measurements simultaneously. First, a comprehensive physical model is established to understand the frequency responses of the CNFA impedance. Second, COMSOL Multiphysics is used to simulate the frequency responses of the CNFA impedance, which provides more insights into the electric field and current density distribution. The impedance of CNFAs decreased with the increased dosage of carbon nanofibers (CNFs). Third, experimental studies are reported in detail. The electrical impedance variation (EZV) of the CNFA in parallel orientation is 151% higher than that of perpendicular orientation at the frequency of 2612 Hz and uniaxial compression stress of 4.65 MPa. The strain-EZV curve obtained from the response spectrum is linear for frequencies ranging from 98 Hz to 463.9 kHz. The strain-EZV curve for 5625 Hz has a linear fit with the gauge factor of 147.78. At 1000 Hz, the CNFA exhibited a repeatable behavior up to 9.35 MPa and detection limit up to the stress of 18.62 MPa.

36 MATERIALS SCIENCE↗

Alpha7 nicotinic acetylcholine receptor activation protects against myocardial reperfusion injury through modulation of autophagy

Alpha7 nicotinic acetylcholine receptor (α7nAChR) activation alleviates myocardial ischemia/reperfusion (MI/R) injury. However, the underlying mechanisms remain unclear. Here, we investigated the role of autophagy in α7nAChR-mediated cardioprotection and the molecular mechanisms involved. Activating α7nAChR with PNU-282987 at the initiation of reperfusion reduced myocardial infarct size in MI/R rats. PNU-282987 treatment also significantly inhibited MI/R-induced myocardial autophagy dysfunction as evidenced by the reduction of LC3-II/LC3-I ratio, Beclin-1 and p62 abundance. In addition, PNU-282987 treatment reduced hypoxia/reoxygenation (H/R)-induced cardiomyocyte injury in vitro, accompanied with the inhibition of Beclin-1-associated autophagy and the restoration of autophagic flux. Interestingly, inhibiting autophagic flux attenuated α7nAChR-afforded improvement of mitochondrial function as well as inhibition of apoptosis in vitro. Mechanistically, co-administration of PNU-282987 with LY294002 (a PI3K inhibitor), AG490 (a JAK2 inhibitor) or Bcl-2 siRNA, but not compound C (an AMPK inhibitor), reduced Bcl-2 level and prevented the modulation of autophagy afforded by PNU-282987 in H/R cardiomyocytes. Collectively, these findings suggest that α7nAChR activation inhibits Beclin-1-associated autophagy dysfunction via the JAK2/Bcl-2 and PI3K/Bcl-2 cascades, leading to cardioprotection against MI/R injury.

60 APPLIED LIFE SCIENCES↗

Improved carrier mobility of chemical vapor deposition-graphene by counter-doping with hydrazine hydrate

We developed a counter-doping method to tune the electronic properties of chemical vapor deposition (CVD)-grown graphene by varying the concentration and time of graphene exposure to hydrazine hydrate (N{sub 2}H{sub 4}·H{sub 2}O). The shift of G and 2D peaks of Raman spectroscopy is analyzed as a function of N{sub 2}H{sub 4}·H{sub 2}O concentration. The result revealed that N{sub 2}H{sub 4}·H{sub 2}O realized n-type doping on CVD grown graphene. X-ray photoelectron spectroscopy measurement proved the existence of nitrogen, which indicated the adsorption of N{sub 2}H{sub 4} on the surface of graphene. After counter-doping, carrier mobility, which was measured by Hall measurements, increased three fold.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗