Li, Z

Publications and source records attributed to Li, Z.

At least 19 records

Search for Double Beta Decays of Xe134 with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% ^{136}Xe and 19.098% ^{134}Xe. The detector operated at the Waste Isolation Pilot Plant between 2010 and 2018 and was designed to search for double beta decay of ^{136}Xe. Data were acquired in two phases separated by a period of detector upgrades. We report on the search for 0νββ and 2νββ decay of ^{134}Xe with Phase II EXO-200 data, with median 90% CL exclusion sensitivity to half-life T_{1/2}^{0ν}≥3.7×10^{23} yr and T_{1/2}^{2ν}≥2.6×10^{21} yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of ^{134}Xe of T_{1/2}^{0ν}≥8.7×10^{23} (90% CL) and the second strongest constraint on the two-neutrino decay of T_{1/2}^{2ν}≥2.9×10^{21} (90% CL), a threefold improvement over the EXO-200 Phase I measurement. New constraints are also set for the 2νββ and 0νββ decays of ^{134}Xe to the lowest excited state of ^{134}Ba.

Al Kharusi, S↗

Measurements of electron transport in liquid and gas Xenon using a laser-driven photocathode

Measurements of electron drift properties in liquid and gaseous xenon are reported. The electrons are generated by the photoelectric effect in a semitransparent gold photocathode driven in transmission mode with a pulsed ultraviolet laser. The charges drift and diffuse in a small chamber at various electric fields and a fixed drift distance of 2.0 cm. At an electric field of 0.5 kV/cm, the measured drift velocities and corresponding temperature coefficients respectively are 1.97 ± 0.04 mm/µs and (-0.69 ± 0.05)%/K for liquid xenon, and 1.42 ± 0.03 mm/µs and (+0.11 ± 0.01)%/K for gaseous xenon at 1.5 bar. In addition, we measure longitudinal diffusion coefficients of 25.7±4.6 cm2/s and 149±23 cm2/s, for liquid and gas, respectively. The quantum efficiency of the gold photocathode is studied at the photon energy of 4.73 eV in liquid and gaseous xenon, and vacuum. These charge transport properties and the behavior of photocathodes in a xenon environment are important in designing and calibrating future large scale noble liquid detectors.

Njoya, Oumarou↗

Characterization of the Hamamatsu VUV4 MPPCs for nEXO

In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range 163 K = T = 233 K. At an over voltage of 3.1 ± 0.2 V and at T = 163 K we report a number of Correlated Avalanches (CAs) per pulse in the 1µs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137 ± 0.002 Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T = 233 K for a mean wavelength of 189 ± 7 nm. At 3.6 ± 0.2 V and 3.5 ± 0.2 V of over voltage we report a PDE of 13.4 ± 2.6 % and 11 ± 2%, corresponding to a saturation PDE of 14.8 ± 2.8 % and 12.2±2.3%, respectively. Both values are well below the 24 % saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5 ± 0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBKLF SiPMs for the final design of the nEXO detector.

Gallina, G↗

Imaging Individual Barium Atoms in Solid Xenon for Barium Tagging in nEXO

The search for neutrinoless double beta decay probes the fundamental properties of neutrinos, including whether or not the neutrino and antineutrino are distinct. Double beta detectors are large and expensive, so background reduction is essential for extracting the highest sensitivity. The identification, or “tagging”, of the 136Ba daughter atom from double beta decay of 136Xe provides a technique for eliminating backgrounds in the nEXO neutrinoless double beta decay experiment. The tagging scheme studied in this work utilizes a cryogenic probe to trap the barium atom in solid xenon, where the barium atom is tagged via fluorescence imaging in the solid xenon matrix. Here we demonstrate imaging and counting of individual atoms of barium in solid xenon by scanning a focused laser across a solid xenon matrix deposited on a sapphire window. When the laser sits on an individual atom, the fluorescence persists for ~30 s before dropping abruptly to the background level, a clear confirmation of one-atom imaging. No barium fluorescence persists following evaporation of a barium deposit to a limit of =0.16%. This is the first time that single atoms have been imaged in solid noble element. It establishes the basic principle of a barium tagging technique for nEXO.

Chambers, C↗

Characterization of an Ionization Readout Tile for nEXO

Anewdesign for the anode of a time projection chamber, consisting of a charge-detecting "tile", is investigated for use in large scale liquid xenon detectors. The tile is produced by depositing 60 orthogonal metal charge-collecting strips, 3 mm wide, on a 10 cm 10 cm fused-silica wafer. These charge tiles may be employed by large detectors, such as the proposed tonne-scale nEXO experiment to search for neutrinoless double-beta decay. Modular by design, an array of tiles can cover a sizable area. The width of each strip is small compared to the size of the tile, so a Frisch grid is not required. A grid-less, tiled anode design is beneficial for an experiment such as nEXO, where a wire tensioning support structure and Frisch grid might contribute radioactive backgrounds and would have to be designed to accommodate cycling to cryogenic temperatures. The segmented anode also reduces some degeneracies in signal reconstruction that arise in large-area crossed-wire time projection chambers. A prototype tile was tested in a cell containing liquid xenon. Very good agreement is achieved between the measured ionization spectrum of a 207Bi source and simulations that include the microphysics of recombination in xenon and a detailed modeling of the electrostatic field of the detector. An energy resolution E=5.5% is observed at 570 keV, comparable to the best intrinsic ionization-only resolution reported in literature for liquid xenon at 936 V/cm.

Jewell, M J.↗

SU-F-P-31: Dosimetric Effects of Roll and Pitch Corrections Using Robotic Table

Purpose: To quantify the dosimetric effect of roll and pitch corrections being performed by two types of robotic tables available at our institution: BrainLabTM 5DOF robotic table installed at VERO (BrainLab&MHI) dedicated SBRT linear accelerator and 6DOF robotic couch by IBA Proton Therapy with QFixTM couch top. Methods: Planning study used a thorax phantom (CIRSTM), scanned at 4DCT protocol; targets (IGTV, PTV) were determined according to the institutional lung site-specific standards. 12 CT sets were generated with Pitch and Roll angles ranging from −4 to +4 degrees each. 2 table tops were placed onto the scans according to the modality-specific patient treatment workflows. The pitched/rolled CT sets were fused to the original CT scan and the verification treatment plans were generated (12 photon SBRT plans and 12 proton conventional fractionation lung plans). Then the CT sets were fused again to simulate the effect of patient roll/pitch corrections by the robotic table. DVH sets were evaluated for all cases. Results: The effect of not correcting the phantom position for roll/pitch in photon SBRT cases was reducing the target coverage by 2% as maximum; correcting the positional errors by robotic table varied the target coverage within 0.7%. in case of proton treatment, not correcting the phantom position led to the coverage loss up to 4%, applying the corrections using robotic table reduced the coverage variation to less than 2% for PTV and within 1% for IGTV. Conclusion: correcting the patient position by using robotic tables is highly preferable, despite the small dosimetric changes introduced by the devices.

60 APPLIED LIFE SCIENCES↗

SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?

Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were based on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largest potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in cervical HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-103: Analysis of Hepatitis B Virus Reactivation After Conformal Radiotherapy in Patients with Hepatocellular Carcinoma Using the Lyman NTCP Model

Purpose: The aim of this research was to investigate the feasibility of Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model in analyzing hepatitis B virus (HBV) reactivation in patients receiving conformal radiotherapy for patients with hepatocellular carcinoma (HCC). Methods: Between June 2009 and June 2012, 108 HBV-related HCC patients (90 were specifically selected and 18 patients were excluded) treated with conformal RT at three centers were enrolled in this retrospective study. They were all diagnosed as HCC by pathology or cytology. All 90 patients were followed up to September 2013 with a median follow-up time of 25.2 months. The parameters (TD50 (1), n, and m) of the modified LKB NTCP model were derived using maximum likelihood estimation. Bootstrap and leave-one-out were employed to test the generalizability of the results for use in a general population. Results: The incidences of complications in the study population were as follows: radiation-induced liver diseases (RILD) were 17.6%, HBV reactivation was 24.8%, and HBV reactivation-induced hepatitis was 22.7%, respectively. In multivariate analysis, the NTCP (p<0.001), and V20 were associated with HBV reactivation. TD50 (1), m and n were 42.9Gy (95% CI) (38.2–46.8), 0.14 (0.12–0.15) and 0.30 (0.2–0.33), respectively, for HBV reactivation. Bootstrap and leave-one-out results showed that the HBV parameter fits were extremely robust. Conclusion: A modified LKB NTCP model has been established to predict HBV reactivation for patients with HCC receiving conformal RT. The finding derives parameters set to predict potential endpoints of HBV reactivation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-564: 3 Year Experience of Treatment Plan QualityAssurance for Vero SBRT Patients

Purpose: To verify treatment plan monitor units from iPlan treatment planning system for Vero Stereotactic Body Radiotherapy (SBRT) treatment using both software-based and (homogeneous and heterogeneous) phantom-based approaches. Methods: Dynamic conformal arcs (DCA) were used for SBRT treatment of oligometastasis patients using Vero linear accelerator. For each plan, Monte Carlo calculated treatment plans MU (prescribed dose to water with 1% variance) is verified first by RadCalc software with 3% difference threshold. Beyond 3% differences, treatment plans were copied onto (homogeneous) Scanditronix phantom for non-lung patients and copied onto (heterogeneous) CIRS phantom for lung patients and the corresponding plan dose was measured using a cc01 ion chamber. The difference between the planed and measured dose was recorded. For the past 3 years, we have treated 180 patients with 315 targets. Out of these patients, 99 targets treatment plan RadCalc calculation exceeded 3% threshold and phantom based measurements were performed with 26 plans using Scanditronix phantom and 73 plans using CIRS phantom. Mean and standard deviation of the dose differences were obtained and presented. Results: For all patient RadCalc calculations, the mean dose difference is 0.76% with a standard deviation of 5.97%. For non-lung patient plan Scanditronix phantom measurements, the mean dose difference is 0.54% with standard deviation of 2.53%; for lung patient plan CIRS phantom measurements, the mean dose difference is −0.04% with a standard deviation of 1.09%; The maximum dose difference is 3.47% for Scanditronix phantom measurements and 3.08% for CIRS phantom measurements. Conclusion: Limitations in secondary MU check software lead to perceived large dose discrepancies for some of the lung patient SBRT treatment plans. Homogeneous and heterogeneous phantoms were used in plan quality assurance for non-lung patients and lung patients, respectively. Phantom based QA showed the relative good agreement between iPlan calculated dose and measured dose.

60 APPLIED LIFE SCIENCES↗

SU-E-J-74: Dosimetric Advantages of Adaptive Radiotherapy for Head and Neck Cancer Are Confirmed with Weekly CBCT Images

Purpose: Our previous study showed that weekly dose monitoring using cone-beam CT (CBCT) images can guide the timing and need for adaptive re-planning during the treatment of head and neck (HN) cancer. Here we aim to confirm the dosimetric improvement of adaptive radiotherapy (ART) using weekly CBCTs. Methods: We randomly selected seven HN patients treated with ART due to noticeable anatomic changes. Twenty weekly images acquired during the second treatment course were included. These CBCTs were aligned with both the initial and re-planning simulation CTs according to the clinical shifts. Daily doses were re-calculated for both the initial and adaptive plans. Contours of the tumor and organs-at-risk (OARs) were manually delineated by a physician on the re-planning CT and then were transferred to the CBCTs for plan evaluation. Contour modifications were made based on the daily anatomic changes observed on CBCTs. All patients were treated with 70Gy to the primary tumor and 56Gy to the elective lymph nodes. Results: Volumetric changes of the tumor (range — 43.9%∼+15.9%) were observed. The average D99 to the primary tumor was (70.1±2.0)Gy (range 62.2∼72.5Gy) for the adaptive plan and (66.0±5.5)Gy (range 50.9∼70.7Gy) for the initial plan(p<<0.01). The average D99 to the elective neck was (56.3±1.3)Gy (range 52.8∼59.2Gy) for the adaptive plan and (52.4±7.0)Gy (range 37.7∼58.6Gy) for the initial plan(p=0.01). The parotid decreased in volume during the treatment course (range 7.3%∼42.2%). The average D-mean to the spared parotid decreased by 15.3% (p=0.002) for the adaptive plan when compared to the original. With ART, 4 out of 7 patients experienced better sparing of the spinal cord (D-max reduced by 2.5%∼10.2%) and the oral cavity (D-mean reduced by 3.5%∼20.1%). Conclusion: Weekly CBCT dosimetry confirms that ART is an effective method to accommodate on-treatment anatomic changes. In select patients, tumor coverage and OAR sparing may be improved with ART. Research is funded by Siemens.

60 APPLIED LIFE SCIENCES↗

SU-E-T-03: 3 Year Clinical Experience with the IBA Proton Eyeline

Purpose: Over the past 3 years, more than 50 patients with ocular disease have been treated with a prototype commercial eyeline developed by Ion Beam Applications (IBA). It is particularly crucial for the dosimetry of the machine to be accurate, precise, and reproducible because of the small treatment volumes and several surrounding critical structures. A quality assurance (QA) program has been developed in order to regularly check and record the machine’s dosimetry over time. In this study we have summarized and evaluated three years of patient and system QA data for the eyeline prototype. Methods: In order to accurately deliver the prescribed dose to the patient’s treatment site, an output model was created based on several machine parameters. This output model, along with the requested system parameters, are regularly checked and recorded by a QA program. 10 standard proton fields have been created which have regular QA performed monthly with a water tank and parallel-plate chamber, and recorded in a database. QA has additionally been performed for each patient-specific treatment field. This is to verify and evaluate the patient output model as well as the system parameters for range&modulation combinations different than the standard QA fields. Results: 140 beam measurements have been analyzed for range, modulation, and output. The range is typically within tolerance, although there are about 6 cases where the system did not perform as expected. The modulation appears to be very stable, always being within tolerance. Output for the standard QA fields are typically within 2.5% from the baseline value. The patient output measurements agree within 2.5% from the model. Conclusion: Overall the eyeline performs well within the tolerances set, and the patient output measurements agree within 2% of the model.

60 APPLIED LIFE SCIENCES↗