Electrification Options for Multi-Family Water Heating in Cold Climates - Final Report

In multi-family buildings, large water storage tanks in centralized domestic hot water (DHW) systems can serve as thermal energy storage (TES) batteries to mitigate grid impact. These systems offer demand shift and efficiency benefits, significantly reducing peak power consumption, particularly in cold climates. This study evaluates the load-shifting benefits of a centralized heat pump water heater (HPWH) system equipped with a CO2 heat pump in multi-family buildings through simulation. The heat pump system and water storage tank are sized using design-day sizing. A finite-element-based stratified tank model and CO2 heat pump performance map from a commercial DHW product are used. Annual simulations are conducted to assess the benefits of the centralized DHW system for energy efficiency improvements, load shifting, and emission reductions. These simulations incorporate utility tariffs and marginal grid emission data from Los Angeles and Chicago. In Los Angeles, using a water tank as a thermal battery achieves 7.4% utility cost savings and 10.2% emission reduction. In Chicago, compared to HPWH conventional operation without preheating, TES-enabled central HPWH provides 15% utility cost savings and 13% emission reduction. The case study demonstrates that the demand reduction potential of central CO2 HPWHs is significant in cold climate regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗

A Simulation Study of 120V Heat Pump Water Heaters

A 120 V heat pump water heater (HPWH) is a direct plug-in option to replace gas water heater (WH) without needing expensive electric panel upgrade to 220 V. To enable the smooth transition, the HPWH should provide comparable water heating capacity as the gas WH. WH capacities are rated in the form of first hour rating (FHR). Typical home gas WHs have FHRs > 65 gallon with a 40-gallon water tank. It imposes a major challenge on 120V HPWHs. Most 120V circuits in US can provide 1,800 to 2,400W, not adequate to drive electric resistance heat to boost FHRs. Thus, all the heat needs to come from the heat pump with its top power below 1500 Watts, which is constraint by the installation footprint. This study uses a hardware based, HPWH design model, i.e. the DOE/ORNL Heat Pump Design Model to design a 120V unit with a brazed plate condenser, fin-and-tube evaporator and an adequately sized compressor. To maximize the FHR, multiple strategies were simulated, including use of a mixing valve, overheating the tank temperature to 140F, a new sensing method for quicker response, and an innovative water circulation path. We also simulated 24-hour unform energy factors (UEF) to show the tradeoff between the capacity and operation efficiency. Additionally, we evaluated the impact of insulation thickness on FHR and UEF, to seek further footprint reduction or stretch the tank volume.

Shen, Bo↗