Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Performance and Cost Potential for Exemplar Direct Supercritical Carbon Dioxide Natural Gas Plants

This report presents the techno-economic analysis (TEA) optimization results of natural gas-fired utility-scale power plants based on the direct supercritical carbon dioxide (sCO 2 ) power cycle. To identify optimum plant configuration, the study also considered three different cases (Case A, Case B, Case C) with varying levels of thermal integration with the plant air separation unit (ASU). A fourth case (Case D), which is based on a patent from 8 Rivers, was also considered and includes thermal integration with the ASU as well as compressed recycle carbon dioxide (CO 2 ) gas. The four direct sCO 2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on an F-class gas turbine with carbon capture and storage (CCS). LCOE of the direct sCO 2 plants is 13.5–17.2 percent higher than the reference NGCC plants with CCS due to higher capital costs associated with the ASU and sCO 2 power block. Recuperators make up over 50 percent of the power cycle costs. Consequently, any research and development (R&D) efforts to reduce the recuperator capital costs will be beneficial for the technology commercialization. The study also investigated the impact of co-firing landfill gas (LFG) and natural gas on plant efficiency, LCOE, and CO 2 emissions. Increasing the LFG co-firing from 0 percent to 50 percent (mass basis), decreased the plant efficiency by 0.3 percentage points and increased the LCOE by 3 percent. Due to high inherent CO 2 capture rates, direct sCO 2 plants have strong potential to achieve net-zero CO 2 emissions with LFG and natural gas co-firing.

03 NATURAL GAS↗

Radial Compressor Design and Off-Design for Trans-critical CO2 Operating Conditions

Presentation for the The 7th International Supercritical CO2 Power Cycles Symposium, February 21 – 24, 2022, San Antonio, Texas. A multi-staged intercooled centrifugal compressor design is performed for an indirect-fired sCO2 cycle and the design point data are used to generate the performance maps using a 2D mean-line analysis code. Fluid and turbomachinery similarity laws are applied to find an appropriate surrogate ideal gas fluid to be used in the design and performance map generation codes. The performance maps are then scaled back for the sCO2 fluid case using the affinity laws.

Uysal, Selcuk Can↗

Radial Compressor Design and Off-Design for Trans-critical CO2 Operating Conditions

A multi-staged intercooled centrifugal compressor design is performed for an indirect-fired sCO2 cycle and the design point data are used to generate the performance maps using a 2D mean-line analysis code. Fluid and turbomachinery similarity laws are applied to find an appropriate surrogate ideal gas fluid to be used in the design and performance map generation codes. The performance maps are then scaled back for the sCO2 fluid case using the affinity laws. The developed methodology is validated using the experimental data for a compressor operating at similar inflow conditions.

Uysal, Selcuk Can↗

Optimized Performance and Cost Potential for Exemplar Indirect SCO 2 Coal Plants

This NETL report presents the techno-economic analysis (TEA) optimization results of coal-fired utility-scale power plants based on the indirect supercritical carbon dioxide (sCO 2 ) power cycles both with and without carbon capture and storage (CCS). For the plants without CCS, the heat source is an air-fired circulating fluidized bed (CFB). For plants with CCS, the heat source is an oxy-fired CFB. Four power cycle configurations were examined for this study: recompression cycle (RC) without and with reheat turbine (“RC without reheat” and “RC with reheat”), and partial cooling cycle (PCC) without and with reheat turbine (“PCC without reheat” and “PCC with reheat”).

01 COAL, LIGNITE, AND PEAT↗

Design and dynamic modeling of printed circuit heat exchangers for supercritical carbon dioxide Brayton power cycles

Due to the unique geometries and hydraulics of printed circuit heat exchangers and rapidly changing properties of supercritical carbon dioxide, the effective design and rating of printed circuit heat exchangers is an essential requirement for their use in supercritical carbon dioxide power cycles. In this study, one-dimensional design and dynamic models have been developed in Aspen Custom Modeler for printed circuit heat exchangers utilized in printed circuit heat exchangers Brayton power cycles. The design model is used to determine the optimal geometry parameters by minimizing the metal mass. The dynamic model is used to predict transient behavior and can be easily implemented into system-level models developed in Aspen Plus Dynamics for cycle performance evaluations. In these models, the heat transfer coefficient and friction factor are calculated using data reported by Heatric, a prominent printed circuit heat exchanger manufacturer. Both models are validated by comparing with the data from a small-scale exchanger used in the 100 kWe facility operated by the Naval Nuclear Laboratory, and then applied to design and simulate low- and high-temperature recuperators for a 10 MWe supercritical carbon dioxide indirect recompression closed Brayton cycle, which is of interest to the U.S. Department of Energy. The designs and dynamic responses of the printed circuit heat exchangers are compared with conventional shell-and-tube exchangers and microtube shell-and-tube exchangers for the same applications. Here, the simulation results indicate that the proposed printed circuit heat exchangers have fast dynamic responses due to their small metal masses and high heat transfer coefficients compared with the conventional shell-and-tube exchangers. Even though the metal masses of the designed PCHEs are slightly higher than those of the microtube shell-and-tube exchangers, the printed circuit heat exchangers are still promising candidates for heat recuperation because of their mature manufacturing procedures and abundant laboratory and industrial operating experience.

42 ENGINEERING↗

Optimal design of microtube recuperators for an indirect supercritical carbon dioxide recompression closed Brayton cycle

This paper presents a baseline design and optimization approach developed in Aspen Custom Modeler (ACM) for microtube shell-and-tube exchangers (MSTEs) used for high- and low-temperature recuperation in a 10 MWe indirect supercritical carbon dioxide (sCO 2 ) recompression closed Brayton cycle (RCBC). The MSTE-type recuperators are designed using one-dimensional models with thermal-hydraulic correlations appropriate for sCO 2 and properties models that capture considerable nonlinear changes in CO 2 properties near the critical and pseudo-critical points. Using the successive quadratic programming (SQP) algorithm in ACM, optimal recuperator designs are obtained for either custom or industry-standard microtubes considering constraints based on current advanced manufacturing techniques. The three decision variables are the number of tubes, tube pitch-to-diameter ratio, and tube diameter. Five different objective functions based on different key design measures are considered: minimization of total heat transfer area, heat exchanger volume, metal weight, thermal residence time, and maximization of compactness. Sensitivities studies indicate the constraint on the maximum number of tubes per shell does affect the number of parallel heat exchanger trains but not the tube selection, total number of tubes, tube length and other key design measures in the final optimal design when considering industry-standard tubes. In this study, the optimally designed high- and low-temperature recuperators have 47,000 3/32 inch tubes and 63,000 1/16 inch tubes, respectively. In addition, sensitivities to the design temperature approach and maximum allowable pressure drop are studied, since these specifications significantly impact the optimal design of the recuperators as well as the thermal efficiency and the economic performance of the entire sCO 2 Brayton cycle.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

sCO2 Research & Development at NETL

This presentation briefly describes the R&D efforts on supercritical CO2 (sCO2) power cycles currently being performed at NETL's Research & Innovation Center. R&D is ongoing in five main areas: Aerothermal/Heat Transfer, Oxy-combustion, sCO2 Materials, Dynamic Cycle Modeling, and Techno-economic Analyses. This presentation was delivered at the 2017 sCO2 Summit in Albuquerque, NM, on 11/15/17.

Weiland, Nathan↗