Search NASA⌕ Search

Engineering topics

Liesenfelt, Michael

Publications and source records attributed to Liesenfelt, Michael.

Quantification of 238U Holdup using Iterative, Point-Cloud-Based Compton Imaging

U holdup has impacts on several aspects of operation: Worker dose, Criticality safety, Safeguards, Outage planning. Generalized Geometry Holdup (GGH) currently estimates U mass within a high uncertainty band (± 50%). This method seeks to improve this uncertainty via quantitative Compton imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improved Angular Uncertainty Estimation for Compton Imagers

Compton imaging is a method for localizing a photon source using Compton scatter events as measured by a position sensitive photon detector. Using the measured interaction positions and energy depositions for a Compton event, a cone can be back projected which represents all possible origin locations for that source photon. Given enough Compton events, the source can be localized via identifying the regions where many of these cones intersect. An illustration of this effect is given in the figure below. The region intersected by the three cones in this case is a likely origin point for the photon source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Investigation of a Scalable Fast Neutron Radiography Panel

Advances in flat-panel radiography device design have increased the use of radiation imaging as a nondestructive evaluation tool. Neutron radiography offers many advantages compared to photon-based radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed Tomography by Combining Transmission and Scatter Radiography Methods

In 2015, approximately 13 billion tons of freight was transported in the US, roughly 40 tons per person. 40% of all freight on a ton-mile basis will be transported by railroads. Class I railroads have approximately 140,000 miles (224,000 km) of railroad track across the country. Approximately 3,200 crossties per mile secure the rails at the proper gauge, transmit loads to the ballast, and prevent lateral and longitudinal shifting. Wood crossties can fail in many ways including rotting, breaking, cracking, and splitting. Developing new technologies to inspect these crossties are necessary to help maintain and ensure safe railroad operations. The Georgetown Railroad Equipment Company partnered with the University of Florida to develop the Aurora Xi X-ray backscatter inspection system. This system generates 2D backscatter images at 25 mph to detect weakness in wood crossties long before the internal degradation is visible on the tie surface. The railroad industry has a need for a high-speed high resolution 3D inspection method to inspect approximately 20 million newly fabricated railroad crossties per year. Currently new ties are not radiographically inspected to reject internal flaws and verify that rot prevention treatments have adequately penetrated into the crosstie. Current spiral scan computed tomography (CT) systems are not designed for the 100 cm/s to 400 cm/s speed of a wood crosstie production line. Building on the technology developed for the 2D Aurora Xi system, a new 3D fan-beam inspection system and CT method is being developed. A previous scatter CT method by Arsenault and Hussein required moving the Xray source to many positions, averaging the X-ray spectra, and ignoring the Compton scatter change of energy. The proposed design and method combines transmission and scatter radiography in all directions without moving or rotating the X-ray sources or detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗