Search NASA⌕ Search

Engineering topics

Lin, Chen

Publications and source records attributed to Lin, Chen.

31 records · Page 2

Experimental validation of a method characterizing bow tie filters in CT scanners using a real-time dose probe

Purpose: Beam-shaping or ''bow tie'' (BT) filters are used to spatially modulate the x-ray beam in a CT scanner, but the conventional method of step-and-shoot measurement to characterize a beam's profile is tedious and time-consuming. The theory for characterization of bow tie relative attenuation (COBRA) method, which relies on a real-time dosimeter to address the issues of conventional measurement techniques, was previously demonstrated using computer simulations. In this study, the feasibility of the COBRA theory is further validated experimentally through the employment of a prototype real-time radiation meter and a known BT filter. Methods: The COBRA method consisted of four basic steps: (1) The probe was placed at the edge of a scanner's field of view; (2) a real-time signal train was collected as the scanner's gantry rotated with the x-ray beam on; (3) the signal train, without a BT filter, was modeled using peak values measured in the signal train of step 2; and (4) the relative attenuation of the BT filter was estimated from filtered and unfiltered data sets. The prototype probe was first verified to have an isotropic and linear response to incident x-rays. The COBRA method was then tested on a dedicated breast CT scanner with a custom-designed BT filter and compared to the conventional step-and-shoot characterization of the BT filter. Using basis decomposition of dual energy signal data, the thickness of the filter was estimated and compared to the BT filter's manufacturing specifications. The COBRA method was also demonstrated with a clinical whole body CT scanner using the body BT filter. The relative attenuation was calculated at four discrete x-ray tube potentials and used to estimate the thickness of the BT filter. Results: The prototype probe was found to have a linear and isotropic response to x-rays. The relative attenuation produced from the COBRA method fell within the error of the relative attenuation measured with the step-and-shoot method. The BT filter thickness estimates resulting from the dual energy scans on the breast CT system were equivalent to the manufacturing specifications. The clinical CT evaluation produced data conceptually similar to previous computer simulations and plausible relative attenuation profiles were observed. Conclusions: The COBRA method is a fast and accurate method for BT filter characterization, which requires a simple experimental setup in a clinical environment. Because of the ease of data acquisition, multienergy scans can be acquired which allow characterization of the BT filter thickness.

60 APPLIED LIFE SCIENCES↗

Detecting multipartite classical states and their resemblances

We study various types of multipartite states lying near the quantum-classical boundary. The so-called classical states are precisely those in which each party can perfectly identify a locally held state without disturbing the global state, a task known as nondisruptive local state identification (NDLID). We show NDLID to be closely related local broadcasting, and we introduce a class of states called generalized classical states which allow for both NDLID and multipartite broadcasting when the most general quantum measurements are permitted. Simple analytical methods and a physical criterion are given for detecting whether a multipartite state is classical or generalized classical. For deciding the latter, a semidefinite programming algorithm is presented which may find use in other fields such as signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multicopy and stochastic transformation of multipartite pure states

Characterizing the transformation and classification of multipartite entangled states is a basic problem in quantum information. We study the problem under the two most common environments, local operations and classical communications (LOCC), stochastic LOCC and two more general environments, multicopy LOCC (MCLOCC), and multicopy SLOCC (MCSLOCC). We show that two transformable multipartite states under LOCC or SLOCC are also transformable under MCLOCC and MCSLOCC. What is more, these two environments are equivalent in the sense that two transformable states under MCLOCC are also transformable under MCSLOCC, and vice versa. Based on these environments we classify the multipartite pure states into a few inequivalent sets and orbits, between which we build the partial order to decide their transformation. In particular, we investigate the structure of SLOCC-equivalent states in terms of tensor rank, which is known as the generalized Schmidt rank. Given the tensor rank, we show that Greenberger-Horne-Zeilinger states can be used to generate all states with a smaller or equivalent tensor rank under SLOCC, and all reduced separable states with a cardinality smaller than or equivalent to the tensor rank under LOCC. Using these concepts, we extended the concept of the ''maximally entangled state'' in the multipartite system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Connections of geometric measure of entanglement of pure symmetric states to quantum state estimation

We study the geometric measure of entanglement (GM) of pure symmetric states related to rank 1 positive-operator-valued measures (POVMs) and establish a general connection with quantum state estimation theory, especially the maximum likelihood principle. Based on this connection, we provide a method for computing the GM of these states and demonstrate its additivity property under certain conditions. In particular, we prove the additivity of the GM of pure symmetric multiqubit states whose Majorana points under Majorana representation are distributed within a half sphere, including all pure symmetric three-qubit states. We then introduce a family of symmetric states that are generated from mutually unbiased bases and derive an analytical formula for their GM. These states include Dicke states as special cases, which have already been realized in experiments. We also derive the GM of symmetric states generated from symmetric informationally complete POVMs (SIC POVMs) and use it to characterize all inequivalent SIC POVMs in three-dimensional Hilbert space that are covariant with respect to the Heisenberg-Weyl group. Finally, we describe an experimental scheme for creating the symmetric multiqubit states studied in this article and a possible scheme for measuring the permanence of the related Gram matrix.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Computation of the geometric measure of entanglement for pure multiqubit states

We provide methods for computing the geometric measure of entanglement for two families of pure states with both experimental and theoretical interests: symmetric multiqubit states with non-negative amplitudes in the Dicke basis and symmetric three-qubit states. In addition, we study the geometric measure of pure three-qubit states systematically in virtue of a canonical form of their two-qubit reduced states and derive analytical formulas for a three-parameter family of three-qubit states. Based on this result, we further show that the W state is the maximally entangled three-qubit state with respect to the geometric measure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasma Channel Diagnostic Based on Laser Centroid Oscillations

A technique has been developed for measuring the properties of discharge-based plasma channels by monitoring the centroid location of a laser beam exiting the channel as a function of input alignment offset between the laser and the channel. The centroid position of low-intensity (<10{sup 14}Wcm{sup -2}) laser pulses focused at the input of a hydrogen-filled capillary discharge waveguide was scanned and the exit positions recorded to determine the channel shape and depth with an accuracy of a few %. In addition, accurate alignment of the laser beam through the plasma channel can be provided by minimizing laser centroid motion at the channel exit as the channel depth is scanned either by scanning the plasma density or the discharge timing. The improvement in alignment accuracy provided by this technique will be crucial for minimizing electron beam pointing errors in laser plasma accelerators.

43 PARTICLE ACCELERATORS↗

Evaluation of two different entanglement measures on a bound entangled state

We consider the mixed three-qubit bound entangled state defined as the normalized projector on the subspace that is complementary to an unextendible product basis [C. H. Bennett et al., Phys. Rev. Lett. 82, 5385 (1999)]. Using the fact that no product state lies in the support of that state, we compute its entanglement by providing a basis of its subspace formed by ''minimally entangled'' states. The approach is in principle applicable to any entanglement measure; here we provide explicit values for both the geometric measure of entanglement and a generalized concurrence.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GeV Electron Beams from a Capillary Discharge Guided Laser Plasma Accelerator

Laser plasma acceleration (LPA) up to 1 GeV has been realized at Lawrence Berkeley National Laboratory by using a capillary discharge waveguide. In this paper, the capillary discharge guided LPA system including a broadband single-shot electron spectrometer is described. The spectrometer was designed specifically for LPA experiments and has amomentumacceptance of 0.01 - 1.1 GeV/c with a percent level resolution. Experiments using a 33 mm long, 300 mu m diameter capillary demonstrated the generation of high energy electron beams up to 1 GeV. By de-tuning discharge delay from optimum guiding performance, selftrapping and acceleration were found to be stabilized producing 460 MeV electron beams.

43 PARTICLE ACCELERATORS↗

Wavefront-sensor-based electron density measurements for laser-plasma accelerators

Characterization of the electron density in laser produced plasmas is presented using direct wavefront analysis of a probe laser beam. The performance of a laser-driven plasma-wakefield accelerator depends on the plasma wavelength and hence on the electron density. Density measurements using a conventional folded-wave interferometer and using a commercial wavefront sensor are compared for different regimes of the laser-plasma accelerator. It is shown that direct wavefront measurements agree with interferometric measurements and, because of the robustness of the compact commercial device, offer greater phase sensitivity and straightforward analysis, improving shot-to-shot plasma density diagnostics.

43 PARTICLE ACCELERATORS↗

Sudden death of distillability in qutrit-qutrit systems

We introduce the concept of distillability sudden death, i.e., free entangled states can evolve into nondistillable (bound entangled or separable) states in finite time under local noise. We describe the phenomenon through a specific model of local dephasing noise and compare the behavior of states in terms of the Bures fidelity. Then we propose a few methods to avoid distillability sudden death of states under (general) local dephasing noise so that free entangled states can be robust against decoherence. Moreover, we find that bound entangled states are unstable in the limit of infinite time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction of 18-keV O{sup -} ions with Al{sub 2}O{sub 3} nanocapillaries

The transmission of 18-keV O{sup -} ions through Al{sub 2}O{sub 3} nanocapillaries with 50 nm in diameter and 12 {mu}m in length is studied in this work. By measuring angular distribution of transmitted particles when capillaries were tilted with respect to incident ion beam, two peaks were observed. It is distinguished that one of them is composed by direct transmitted ions and another one is composed by scattered ions. A phenomenon referred to as guiding effect, as found for highly charged ions and low-energy electrons, was observed. When negative ions (18-keV O{sup -}) are transmitted through nanocapillaries, most of them were ionized to neutral atoms and even positive ions. The intensity of transmitted particles (O{sup -}, O{sup 0}, and O{sup +}) decreased when the tilt angle increased. In transmitted particles, the fraction of O{sup -} declined but that of O{sup 0} and O{sup +} ions grew when the tilt angle grew. Both elastic collision and electrostatic scattering were found in scattered ions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of Human Muscle Protein Measurement with MRI

It is known that micro-gravity has a strong influence on the human musculoskeletal system. A number of studies have shown that significant changes in skeletal muscles occur in both space flight and bedrest simulation. In our 5 week bedrest study, the cross-sectional area of soleus-gastrocnemius decreased about 12% while the cross-sectional area of anterior calf muscles decreased about 4%. Using volume measurements, these losses increased after 17 weeks to approximately 30% and 21% respectively. Significant muscle atrophy was also found on the SL-J crew members after only 8 days in space. It is important that these effects are fully understood so that countermeasures can be developed. The same knowledge might also be useful in preventing muscle atrophy related to other medical problems. A major problem with anatomical measurements of muscle during bed rest and microgravity is the influence of fluid shifts and water balance on the measurement of muscle volume, especially when the exposure duration is short and the atrophy is relatively small. Fluid shifts were documented in Skylab by visual observations of blood vessel distention, rapid changes in limb volume, center of mass measurements and subjective descriptions such as puffy faces and head fullness. It has been reported that the muscle water content of biopsied soleus muscles decreased following 8 hours of head down tilt bed rest. Three aspects of fluid shifts that can affect volume measurements are: first, the shift of fluid that occurs whenever there is a change from upright to a recumbent position and vice versa; second, the potential for fluid accumulation in the lower limbs resulting from muscle damage caused by overextending atrophied muscle or swelling caused by deconditioned precapillary sphincter muscles during reambulation; third, the net change of hydration level during and after bed rest or spaceflight. Because of these transitory fluid shifts, muscle protein is expected to represent muscle capacity better than does muscle volume. The purpose of this study is to test the feasibility of using MRI to quantify of muscle protein and water content changes in muscle.

Lin, Chen↗

Predicting Bone Mechanical Properties of Cancellous Bone from DXA, MRI, and Fractal Dimensional Measurements

This project was aimed at making predictions of bone mechanical properties from non-invasive DXA and MRI measurements. Given the bone mechanical properties, stress calculations can be made to compare normal bone stresses to the stresses developed in exercise countermeasures against bone loss during space flight. These calculations in turn will be used to assess whether mechanical factors can explain bone loss in space. In this study we assessed the use of T2(sup *) MRI imaging, DXA, and fractal dimensional analysis to predict strength and stiffness in cancellous bone.

Harrigan, Timothy P.↗