Search NASA⌕ Search

Engineering topics

Lin, J

Publications and source records attributed to Lin, J.

At least 19 records

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

Investigation of background electron emission in the LUX detector

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of signals from electron emission processes in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper, we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying these electron backgrounds under different experimental conditions, we identified the possible mechanisms that may contribute to the electron emission. We report the observed electron event rate in LUX after background rejection, and discuss how such backgrounds can be further mitigated in ongoing and future xenon-based dark matter experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A combined capacitance-voltage and hard x-ray photoelectron spectroscopy characterisation of metal/Al{sub 2}O{sub 3}/In{sub 0.53}Ga{sub 0.47}As capacitor structures

Capacitance-Voltage (C-V) characterization and hard x-ray photoelectron spectroscopy (HAXPES) measurements have been used to study metal/Al{sub 2}O{sub 3}/In{sub 0.53}Ga{sub 0.47}As capacitor structures with high (Ni) and low (Al) work function metals. The HAXPES measurements observe a band bending occurring prior to metal deposition, which is attributed to a combination of fixed oxide charges and interface states of donor-type. Following metal deposition, the Fermi level positions at the Al{sub 2}O{sub 3}/In{sub 0.53}Ga{sub 0.47}As interface move towards the expected direction as observed from HAXPES measurements. The In{sub 0.53}Ga{sub 0.47}As surface Fermi level positions determined from both the C-V analysis at zero gate bias and HAXPES measurements are in reasonable agreement. The results are consistent with the presence of electrically active interface states at the Al{sub 2}O{sub 3}/In{sub 0.53}Ga{sub 0.47}As interface and suggest an interface state density increasing towards the In{sub 0.53}Ga{sub 0.47}As valence band edge.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-E-J-108: Template Matching Based On Multiple Templates Can Improve the Tumor Tracking Performance When There Is Large Tumor Deformation

Purpose: Recently, template matching has been shown to be able to track tumor motion on cine-MRI images. However, artifacts such as deformation, rotation, and/or out-of-plane movement could seriously degrade the performance of this technique. In this work, we demonstrate the utility of multiple templates derived from different phases of tumor motion in reducing the negative effects of artifacts and improving the accuracy of template matching methods. Methods: Data from 2 patients with large tumors and significant tumor deformation were analyzed from a group of 12 patients from an earlier study. Cine-MRI (200 frames) imaging was performed while the patients were instructed to breathe normally. Ground truth tumor position was established on each frame manually by a radiation oncologist. Tumor positions were also automatically determined using template matching with either single or multiple (5) templates. The tracking errors, defined as the absolute differences in tumor positions determined by the manual and automated methods, when using either single or multiple templates were compared in both the AP and SI directions, respectively. Results: Using multiple templates reduced the tracking error of template matching. In the SI direction where the tumor movement and deformation were significant, the mean tracking error decreased from 1.94 mm to 0.91 mm (Patient 1) and from 6.61 mm to 2.06 mm (Patient 2). In the AP direction where the tumor movement was small, the reduction of the mean tracking error was significant in Patient 1 (from 3.36 mm to 1.04 mm), but not in Patient 2 ( from 3.86 mm to 3.80 mm). Conclusion: This study shows the effectiveness of using multiple templates in improving the performance of template matching when artifacts like large tumor deformation or out-of-plane motion exists. Accurate tumor tracking capabilities can be integrated with MRI guided radiation therapy systems. This work was supported in part by grants from NIH/NCI CA 124766 and Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

A combined hard x-ray photoelectron spectroscopy and electrical characterisation study of metal/SiO{sub 2}/Si(100) metal-oxide-semiconductor structures

Combined hard x-ray photoelectron spectroscopy (HAXPES) and electrical characterisation measurements on identical Si based metal-oxide-semiconductor structures have been performed. The results obtained indicate that surface potential changes at the Si/SiO{sub 2} interface due to the presence of a thin Al or Ni gate layer can be detected with HAXPES. Changes in the Si/SiO{sub 2} band bending at zero gate voltage and the flat band voltage for the case of Al and Ni gate layers derived from the silicon core levels shifts observed in the HAXPES spectra are in agreement with values derived from capacitance-voltage measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ASYMMETRIC MAGNETIC RECONNECTION IN SOLAR FLARE AND CORONAL MASS EJECTION CURRENT SHEETS

We present two-dimensional resistive magnetohydrodynamic simulations of line-tied asymmetric magnetic reconnection in the context of solar flare and coronal mass ejection current sheets. The reconnection process is made asymmetric along the inflow direction by allowing the initial upstream magnetic field strengths and densities to differ, and along the outflow direction by placing the initial perturbation near a conducting wall boundary that represents the photosphere. When the upstream magnetic fields are asymmetric, the post-flare loop structure is distorted into a characteristic skewed candle flame shape. The simulations can thus be used to provide constraints on the reconnection asymmetry in post-flare loops. More hard X-ray emission is expected to occur at the footpoint on the weak magnetic field side because energetic particles are more likely to escape the magnetic mirror there than at the strong magnetic field footpoint. The footpoint on the weak magnetic field side is predicted to move more quickly because of the requirement in two dimensions that equal amounts of flux must be reconnected from each upstream region. The X-line drifts away from the conducting wall in all simulations with asymmetric outflow and into the strong magnetic field region during most of the simulations with asymmetric inflow. There is net plasma flow across the X-line for both the inflow and outflow directions. The reconnection exhaust directed away from the obstructing wall is significantly faster than the exhaust directed toward it. The asymmetric inflow condition allows net vorticity in the rising outflow plasmoid which would appear as rolling motions about the flux rope axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and Numerical Studies on the Formability of Materials in Hot Stamping and Cold Die Quenching Processes

Formability of steel and aluminium alloys in hot stamping and cold die quenching processes is studied in this research. Viscoplastic-damage constitutive equations are developed and determined from experimental data for the prediction of viscoplastic flow and ductility of the materials. The determined unified constitutive equations are then implemented into the commercial Finite Element code Abaqus/Explicit via a user defined subroutine, VUMAT. An FE process simulation model and numerical procedures are established for the modeling of hot stamping processes for a spherical part with a central hole. Different failure modes (failure takes place either near the central hole or in the mid span of the part) are obtained. To validate the simulation results, a test programme is developed, a test die set has been designed and manufactured, and tests have been carried out for the materials with different forming rates. It has been found that very close agreements between experimental and numerical process simulation results are obtained for the ranges of temperatures and forming rates carried out.

36 MATERIALS SCIENCE↗

Lifshitz transition in two-dimensional spin density wave models.

We argue that both pocket-disappearing and neck-disrupting types of Lifshitz transitions can be realized in two-dimensional spin-density wave models for underdoped cuprates, and study both types of transitions with impurity scattering treated in the self-consistent Born approximation. We first solve for the electron self-energy from the self-consistent equation, and then study the low-temperature electrical conductivity and thermopower. Close to the Lifshitz transition, the thermopower is strongly enhanced. For the pocket-disappearing type, it has a sharp peak while for the neck-disrupting type, it changes sign at the transition, with its absolute value peaked on both sides of the transition. We discuss possible applications to underdoped cuprates.

36 MATERIALS SCIENCE↗

STATISTICAL STUDY OF CORONAL MASS EJECTIONS WITH AND WITHOUT DISTINCT LOW CORONAL SIGNATURES

Taking advantage of the two viewpoints of the STEREO spacecraft, we present a statistical study of coronal mass ejections (CMEs) with and without distinct low coronal signatures (LCSs) from 2009 January 1 to August 31. During this period, the lines of sight from STEREO A and B are almost perpendicular and nearly a quarter of the Sun was observed by both. We identified 34 CMEs that originated from around this area and find that (1) about 1 out of 3 CMEs that were studied during 8 months of solar minimum activity are stealth CMEs; a CME is stealth if no distinct LCS (such as coronal dimming, coronal wave, filament eruption, flare, post-eruptive arcade) can be found on the disk. (2) The speeds of the stealth CMEs without LCSs are typically below 300 km s{sup -1}. Comparing with the slow CMEs with LCSs, the stealth CMEs did not show any clear differences in their velocity and acceleration evolution. (3) The source regions of the stealth CMEs are usually located in the quiet Sun rather than active regions. Detailed study indicates that more than half of the stealth CMEs in this paper showed some faint change of the coronal structures (likely parts of flux ropes) when they could be observed over the solar limb before or during the CME evolution. Finally, we note that space weather detection systems based on LCSs totally independent of coronagraph data may fail to detect a significant proportion of CMEs.

79 ASTRONOMY AND ASTROPHYSICS↗

Lifshitz transition in underdoped cuprates.

Recent studies show that quantum oscillations thought to be associated with a density wave reconstructed Fermi surface disappear at a critical value of the doping for YBa{sub 2}Cu{sub 3}O{sub 6+y} and the cyclotron mass diverges as the critical value is approached from the high doping side. We argue that the phenomenon is due to a Lifshitz transition where the pockets giving rise to the quantum oscillations connect to form an open (quasi-one-dimensional) Fermi surface. The estimated critical doping is close to that found by experiment and the theory predicts a logarithmic divergence of the cyclotron mass with a coefficient comparable to that observed in experiment.

43 PARTICLE ACCELERATORS↗