Application of a deep learning semantic segmentation model to helium bubbles and voids in nuclear materials

Imaging nanoscale radiation-induced defects using the transmission electron microscope (TEM) is a key factor in the successful implementation of materials for nuclear energy structural applications. Analyzing each defect in a TEM micrograph is currently a manual task. To identify the defects in a single image can take anywhere from 15 min to an hour and a project can require the analysis of anywhere from tens to ≥ 100 images. Here, we use artificial intelligence (AI) models to automate this task. For simplification, we evaluated images with only a single type of defect; helium bubbles. Additionally, we performed semantic segmentation of these helium bubble defects in electron microscopy images of irradiated FeCrAl alloys using a deep learning DefectSegNet model. This model, which was previously used to classify crystal defects, is inspired by the classic DenseNet and U-Net image segmentation models. It claims high spatial resolution, but has poor performance at object boundaries. Our paper improves the DefectSegNet model’s application by adding two new features. First, the DefectSegNet model is applied not only to perform calculation pixel-wise but also object (or feature) wise. Because object-wise metrics are directly relevant to our final goal of detecting bubbles, whereas pixel-wise classification is only an intermediate step, it is an important part of our study. Second, a distance map loss (DML) function has been added to increase its performance at object boundaries. It is crucial to accurately represent defects boundaries, especially bubbles, in order to track the bubble-induced swelling caused by irradiation. The boundary-focused DML function is also compared to other loss functions like Cross-entropy, Weighted Binary Cross Entropy (WBCE), Dice and Intersection over Union (IOU). Finally, by incorporating new features, we found a marked improvement on segmentation quality and better shape preservation at the boundaries and areas of the bubbles.

42 ENGINEERING↗

Downselection and Basic Properties of Additively Manufactured ODS Alloys

In the AMMT program the work package for development of new materials aimed to explore the advanced manufacturing techniques that are feasible for the manufacturing of advanced materials components. A merit-based feasibility study was attempted to identify an accelerated development path for dispersion strengthened (ODS) alloys by creatively combining additive manufacturing (AM) technologies with the recent advances in ODS materials and traditional manufacturing technologies. For the fiscal year, the primary tasks were focused to develop additive manufacturing (AM) and post-build processing route for oxide dispersion strengthened (ODS) ferritic (Fe-Cr alloy or 14YWT) and austenitic (Fe-Cr-Ni alloys or 316L and 316H) alloys and to perform basic microstructural and mechanical characterizations to provide feedbacks to the alloy and processing design. Further, the multi-laboratory effort created collaboratively a decision criteria matrix to evaluate and downselect the new materials processed by advanced manufacturing methods. This report is to describe the ODS alloy processing routes combining AM processes and post-build thermomechanical treatments, mechanical and microstructural characteristics of the newly developed materials, and the application results of the decision criteria matrix for the AM ODS alloys including a downselected material and feasible processing route. Key mechanical test results including tensile strength, tensile ductility, and fracture toughness data and are reported and explained. Higher strength was measured from the ferritic ODS alloys, while higher ductility and fracture toughness were measured from the austenitic ODS alloys. Many of the decision criteria were scored the same for the AM ferritic and austenitic ODS alloys, however, the generally known fact that the austenitic alloys have higher corrosion resistance and significantly better ductility. Although these scores are not significantly different to make them highly discernable, the austenitic ODS alloys were downselected to be the primary materials group in the future research on ODS materials in AMMT program.

36 MATERIALS SCIENCE↗

A deep learning model for automatic analysis of cavities in irradiated materials

Transmission electron microscopy (TEM) is a commonly used technique in materials science for defect investigation. Quantitative analysis of defects is important for understanding the properties of a material, but manual analysis of TEM micrographs can be time-consuming and prone to error, especially when the defects have irregular shapes rather than spherical shapes. Many existing methods or deep learning models do not handle a wide range of sizes for the same object type within a single image. In this work, we present a framework that enables users to train an instance segmentation model called Mask R- CNN on any microstructure dataset, perform multi-detection on the same image at different scales, and obtain properties (e.g., size, area) of the objects based on the desired shape (e.g., circle, ellipse, rectangle). Additionally, we have developed a parallel detection module that uses multiple GPUs to increase the efficiency of the object detection process. We demonstrate the capabilities of our framework using a set of TEM images of cavities with different shapes, size distributions, and background contrasts. Finally, we show that the performance of our model in terms of density, size, and swelling of the cavities is comparable to the human average and that our model achieves the highest recall value compared to existing methods due to the use of image multi-rescaling.

36 MATERIALS SCIENCE↗

Analysis of position-dependent cavity parameters in irradiated metals to obtain insight on fundamental defect migration phenomena

Motion of point defects is a fundamental process that governs microstructure and properties of materials. Here, we examine the near-surface and grain boundary cavity swelling depth profiles in neutron- and ion-irradiated simple metals (Cu, Ni, and Fe-Cr) and investigate diffusional broadening of implanted Ni ions in Fe-Cr alloys. Vacancy migration energies and radiation-enhanced diffusion were experimentally estimated. Cavity denuded zone widths near planar sinks are shown to be dependent on temperature, damage rate, balance of point defects and sinks, and vacancy migration energies. An enhanced cavity swelling zone adjacent to the void-denuded zone was observed in specimens with low to moderate sink strength and interpreted as evidence of 1D gliding interstitial clusters. Radiation-enhanced diffusional broadening of implanted Ni ions (at 400–550 °C) in Fe and Fe-Cr was up to 250 nm toward the surface, which leads to a much broader near-peak-damage region where cavity swelling is suppressed. Diffusional broadening of implanted ions is calculated to be similarly pronounced for self-ion irradiations, particularly near the peak and higher swelling temperature regimes. Adequately high ion energies (~8–15 MeV) are recommended for ion-irradiation studies to provide a sufficiently broad midrange safe analysis region with minimized surface and injected ion effects.

36 MATERIALS SCIENCE↗

The role of Cr concentration and temperature on cavity swelling with co-injected helium in dual-ion irradiated Fe and Fe-Cr alloys

The level of chromium plays an essential role in irradiation tolerance of Fe-Cr ferritic alloys. However, conflicting results have been reported regarding the dependence of cavity swelling under irradiation on Cr level and temperature. Here, we have performed a comprehensive set of simultaneous dual-ion (Ni + He) irradiations to high dose (~30 displacements per atom, dpa) at 400–550 °C on a series of ultra-high purity Fe and Fe-Cr binary alloys (3–14 wt.%Cr). Helium co-implantation rates of 0.1 and 10 appm He/dpa were selected to examine He synergistic effects relevant for fission and fusion reactor conditions, respectively. Cavities were observed in all irradiated samples by transmission electron microscopy. The results show that higher He implantation rate causes a shift in the swelling peak to higher temperatures in both Fe and Fe-Cr alloys. When assuming smaller cavities as biased sinks, the non-monotonic nature of the cavity swelling behavior is related to the ratio of biased to unbiased point defect sink strengths. Cr-enriched precipitates were observed in Fe-14Cr irradiated at 400 °C by atom probe tomography. Our analysis suggests the formation of Cr-enriched precipitates could suppress cavity swelling for Fe-Cr alloys with Cr content above 10 wt%.

36 MATERIALS SCIENCE↗

The effect of helium on cavity swelling in dual-ion irradiated Fe and Fe-10Cr ferritic alloys

We report Ferritic-martensitic (FM) steels for in-vessel components in proposed fusion reactors are expected to suffer from high levels of displacement damage and helium (He) generation by neutron transmutation. However, a thorough understanding of the He synergistic effects on the cavity swelling in FM steels is still not well established. To gain fundamental insights into the He effect on cavity swelling, high purity Fe and Fe-10 wt.% Cr ferritic model alloys were irradiated with 8 MeV Ni ions and co-implanted He ions at 400 to 550 °C up to 30 displacements per atom (dpa) with He implantation rates of 0.1, 10 and 50 appm He/dpa. The current study focuses on the 50 appm He/dpa, 500 °C behavior vs. 0.1 and 10 appm He/dpa. Irradiation-induced defects, including cavities, dislocation loops, and dislocation networks were characterized using transmission electron microscopy (TEM). In the grain interior, a bimodal cavity size distribution was observed in the 10 and 50 appm He/dpa samples, but not for 0.1 appm He/dpa. Cavity swelling was maximized at intermediate He implantation rates of ~10 appm He/dpa for both ion-irradiated Fe and Fe-10Cr alloys. The cavity swelling behavior as a function of He implantation rate appears to be controlled by the He/dpa-dependent variation of cavity sink strengths. Treating small bubbles as biased sinks for interstitial absorption can significantly increase the ratio of biased to unbiased sink strengths (Q) and results in maximized cavity swelling for a Q ratio close to one.

36 MATERIALS SCIENCE↗

Bubble formation in helium-implanted nanostructured ferritic alloys at elevated temperatures

Helium bubble formation was examined by scanning/transmission electron microscopy (S/TEM) in Fe-9/10Cr binary alloys and two dispersion strengthened nanostructured alloys (CNA3 and 14YWT containing 5–10 nm diameter carbide and oxide particles, respectively) after ex-situ and in-situ He implantation to ~10,000 appm at 500 to 900 °C. The combination of high-resolution STEM images and electron energy loss spectroscopy (EELS) revealed that the Y-Ti-O nanoparticles in 14YWT were uniformly distributed and exhibited a one-to-one relationship for bubble attachment to the nanoclusters. In the in-situ experiment at 900 °C, grain boundary cracking was severe in the Fe-10Cr model alloy, but not in the nanostructured alloys. From 500 to 900 °C, the bubble size generally increased with increasing irradiation temperature, while the bubble density decreased with increasing temperature. At the same temperatures, the bubble size in the implanted materials was in the order of Fe-9/10Cr > CNA3 > 14YWT, while the bubble density showed the opposite order. The observed bubble number densities for the nanostructured alloys are comparable to the nanoparticle density, suggesting that the nanoparticles in both alloys were effective in trapping He. Overall, our results indicate that very high He concentrations can be managed in nanostructured alloys by sequestering the helium into smaller bubbles (which leads to a lower volume swelling value) and to shield He from the grain boundaries. This can be attributed to the much higher sink strength associated with the nanoclusters or the He trapping ability between different types of nanoclusters.

36 MATERIALS SCIENCE↗

Dynamic observation of dual-beam irradiated Fe and Fe-10Cr alloys at 435 °C

The attractive mechanical properties and superior resistance to void-swelling make ferritic/martensitic alloys a promising structural material for advanced nuclear reactors. However, one anomaly that has intrigued researchers for more than 50 years is the proportion of two types of dislocation loops in Fe and Fe-Cr alloys with Burger vectors b=½<111> and b=<100>. Although the possible mechanisms responsible for the presence of <100> loops continue to be the subject of intense modeling studies, there remains incomplete experimental understanding of fundamental irradiation processes in Fe(Cr) alloys. Here, the dose dependence of the irradiation-induced microstructural evolution was examined from 0 to 20 displacement per atom (dpa) in high purity Fe and Fe-10Cr during simultaneous dual-beam (1 MeV Kr + 10 appm He/dpa) irradiation at 435 °C. We experimentally revealed that the mechanism for the formation of <100> loops may not follow the conventional simple dislocation reaction between two 1½<111> loops. Real-time dynamic formation and evolution of defects including black dot loops, loop coarsening, loop decoration, network dislocations, and cavities were demonstrated. Several results indicated that the addition of Cr and He could impede dislocation loop motion. The evolution of the defect size/density and relative fraction of ½<111> vs <100> loops were quantitatively summarized. With increasing dose, ½<111> loops became the dominant type of loop in both materials. Notably, <100> loops were predominantly observed near grain boundaries only for pure Fe, while arrays of nanoscale black dot defects composing the <100> loop strings were observed in plenty in Fe-10Cr.

36 MATERIALS SCIENCE↗

Temperature-dependent cavity swelling in dual-ion irradiated Fe and Fe-Cr ferritic alloys

Fe-Cr ferritic-martensitic (FM) steels are promising structural material candidates for fusion and advanced fission reactors due to their attractive mechanical properties and volumetric swelling resistance. However, significant discrepancies exist regarding the effect of solutes and irradiation temperature on cavity swelling under ion versus neutron irradiation conditions. In this study, simultaneous dual ion irradiations (8 MeV Ni 3+ ions and energy-degraded 3.5 MeV He 2+ ions) were used to quantify the cavity swelling behavior in ultra-high purity Fe and Fe-Cr alloys (3-14 wt.% Cr), Fe-10 wt.% Cr-780 wt.ppm C, and Eurofer97 FM steel. The irradiations were conducted over a wide temperature range (400-550°C) with a mid-range dose of ~30 displacements per atom (dpa) and 0.1 appm/dpa He implantation rate. Here, using state-of-the-art transmission electron microscopy (TEM), we reveal that pure Fe has a ~50°C lower peak swelling temperature difference than Fe-Cr alloys, which is attributed to higher vacancy mobility in pure Fe. Chromium solute appears to strongly suppress cavity swelling in Fe-Cr alloys for temperatures below ~470°C, but seems to have little effect or slightly enhances swelling above ~470°C. Cavities were observed in all the irradiated samples between 400-550°C. This indicates that the narrow temperature range of observable cavities reported in prior ion irradiated Fe-Cr ferritic alloy studies is likely an artifact associated with the use of low ion energies (<5 MeV), which leads to pronounced near-surface and implanted ion effects that suppress cavity swelling even at midrange depths (particularly at high temperatures).