Search NASA⌕ Search

Engineering topics

Lin, Yuehe

Publications and source records attributed to Lin, Yuehe.

208 records · Page 12

Multiplex Electrochemical Immunoassay Using Gold Nanoparticle Probes and Immunochromatographic Strips

We describe a multiplex electrochemical immunoassay based on the use of gold nanoparticle (Au-NP) probes and immunochromatographic strips (ISs). The approach takes advantage of the speed and low cost of the conventional IS tests and the high sensitivities of the nanoparticle-based electrochemical immunoassays. Rabbit IgG(R-IgG) and human IgM (H-IgM) were used as model targets for the demonstration of the proof of concept. The Au-NPs based sandwich immunoreactions were performed on the IS, and the captured gold nanoparticle labels on the test zones were determined by highly-sensitive stripping voltammetric measurement of the dissolved gold ions (III) with a carbon paste electrode. The detection limits are 1.0 and 1.5 ng/mL with the linear ranges of 2.5-250 ng/mL for quantitative detection of R-IgG and H-IgM, respectively. The total assay time is around 25 minutes. Such multiplex electrochemical immunoassay could be readily highly multiplexed to allow simultaneous parallel detection of numerous proteins and is expected to open new opportunities for protein diagnostics and biosecurity.

59 BASIC BIOLOGICAL SCIENCES↗

Dye-Doped Silica Nanoparticle Labels/Protein Microarray for Detection of Protein Biomarkers

Biomarkers serve as indicators of biological and pathological processes, or physiological and pharmacological responses to a drug treatment. Interleukin-6 (IL-6), a biomarker with its important biological and pathological functions, has been studied for decades. Conventional fluorescence immunoassay has been widely used for analysis of biomakers like IL-6. However, single fluorophore labeling shows its limitations of low intensity and poor stability. We report a dye-encapsulated silica nanoparticle as a label, with the advantages of high fluorescence intensity, photostability, and biocompatibility, in conjunction with microarray technology for sensitive immunoassay of IL-6 on a microarray format. The tris (2,2’-bipyridyl)ruthenium (II)chloride hexahydrate (Rubpy) dye incorporated into silica nanoparticles using a simple one-step microemulsion synthesis step. The nanoparticles are uniform in size with a diameter of 50 nm. The microarray fluorescent immunoassay approach based on dye-doped silica nanoparticle labels has high sensitivity for practical applications with a limit of detection for IL-6 down to 0.1 ng mL-1. The calibration curve is linear over the range from 0.1 ng mL-1 to 10 ng mL-1. Furthermore, results illustrated that the assay is highly specific for IL-6 in the presence of range of cytokines or proteins. The RuDS dye-labeled nanoparticles in connection with protein microarrays show the promise for clinical diagnosis of biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Fast test for the durability of PEM fuel cell catalysts

ETek Pt/C catalyst was used as standard materials to develop a new test protocol for fast screening durable catalyst for PEM fuel cells. Potential step (Pstep) method with the upper potential of 1.4V and the potential-static (Pstat) holding at 1.4 V or 1.2V are used to degrade the catalyst. The degradation in the electrochemical surface area (ESA) for Pt/C under Pstep conditions is greatly accelerated as compared with other conditions. The durability of Pt/Vulcan and Pt/CNT were studied using the new protocol with the electrochemical stressing of Pstep(1.4V/0.6V), which provided the same results as those tested using conventional protocols: Pt/CNT is more durable than Pt/Vulcan. This confirms that the new protocol works well in screening catalyst in terms of durability. The new protocol can differentiate the durability of electrocatalysts by shortening the test time to several hours. It is reliable and time-efficient.

30 DIRECT ENERGY CONVERSION↗

Nanoparticles for Enhanced Sensitivity in Electrochemical Immunoassays

In this manuscript, we report on electrochemical biosensors based on various nanoparticles (NPs) as labels for sensitive detection of protein biomarkers. We used silica nanoparticle as a carrier to loading a large amount of electroactive species such as poly(guanine) for sensitive immunoassay of tumor necrosis factor-alpha (TNF-a). We took the advantages of the unique hollow structure and reconstruction properties of apoferritin to prepare Cd3(PO4)2 nanoparticles as labels for sensitive assay of TNF-a. A novel immunochromatographic/electro-chemical biosensor based on quantum dots as labels has also been developed for rapid and sensitive detection of prostate-specific antigen (PSA) in human serum. These biosensors are quite sensitive with the detection limit at pM level and these approaches based on nanoparticle labels offer a new avenue for sensitive detection of protein biomarkers.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Immunoassay of Carcinoembryonic Antigen Based on A Lead Sulfide Nanoparticle Label

We describe a Lead sulfide nanoparticle (PbS NP) based electrochemical immunoassay to detect a tumor biomarker, carcinoembryonic antigen (CEA). Cubic PbS NPs were prepared and functionalized with thioglycolic acid (TGA), which stabilized the formed NPs and offered carboxyl groups to conjugate with CEA antibodies. PbS NP conjugated with monoclonal CEA antibody was used as a label in an immnorecognition event. After a complete sandwich immunoreaction among the primary CEA antibody (immobilized on the carboxyl-modified magnetic beads), CEA, and the PbS-labeled secondary antibody (PbS-anti-CEA), PbS labels were captured to the magnetic-bead (MB) surface through the antibody-antigen immunocomplex. Electrochemical stripping analysis of the captured PbS was used to quantify the concentration of CEA after an acid-dissolution step. The MBs and the magnetic separation platform were used to integrate a facile antibody immobilization with immunoreactions and the isolation of immunocomplexes from reaction solutions in the immunoassay. The performance of this nanoparticle based electrochemical immunoassay was successfully evaluated with human serum spiked with CEA, indicating that this convenient and sensitive technique offers great promise for rapid, simple, and cost-effective analysis of tumor biomarkers in biological fluids.

60 APPLIED LIFE SCIENCES↗

Sensitive electrochemical detection of horseradish peroxidase at disposable screen-printed carbon electrode

A rapid, simple and sensitive electrochemical assay of horseradish peroxidase (HRP) performed on disposable screen-printed carbon electrode was developed. HRP activities were monitored by square-wave voltammetric (SWV) measuring the electroactive enzymatic product in the presence of o-aminophenol and hydrogen peroxide substrate solution. SWV analysis demonstrated a greater sensitivity and shorter analysis time than the widely used amperometric and differential-pulsed voltammetric methods. The voltammetric characteristics of substrate and enzymatic product as well as the parameters of SWV analysis were optimized. Under optimized conditions, a linear response for HRP from 0.003 - 0.1 U/mL and a detection limit of 0.002 U/mL (1.25×10-15 mol in 25 µL) were obtained with a good precision (RSD = 8%; n = 6). This rapid and sensitive HRP assay with microliters-assay volume could be readily integrated to portable devices and point-of-care (POC) diagnosis applications.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Nickel Microstructure on Methane Steam-Reforming Activity of Ni-YSZ Cermet Anode Catalyst

The activity of nickel-yttria stabilized zirconia (Ni-YSZ) solid oxide fuel cell (SOFC) cermet anodes for the steam reforming of methane has been investigated in the absence of electrochemical effects. The cermet was prepared by co-milling and sintering NiO and 5YSZ powders at 1375oC in air. During the high temperature sintering step, NiO dissolved into the YSZ particles to form a solid NiO-YSZ solution. During the subsequent catalyst reduction step, Ni exolved from the YSZ. As a result, many small Ni particles on the order of 10-20 nm formed at the surface of the YSZ. These small particles contribute significantly to the overall reforming activity, along with the large bulk Ni particles within the Ni-YSZ cermet. We have observed high initial activity that decreases by as much as an order of magnitude with time on stream, until the anode catalyst reaches a stable steady state activity. The time to reach this stable activity is a function of the reaction conditions and feed gas composition. Higher temperature, hydrogen partial pressure, and space velocity all accelerated the deactivation rate at a constant steam-to-carbon ratio of 3. Initial and lined out activities and average turnover frequencies were obtained for both Ni-YSZ and bulk Ni, based on a rate expression that is first order in methane and zero order in steam. Comparative tests at 750oC show high initial activity on a per-Ni site basis with both materials, but these turnover rates decline over a period of a few hours. Following lineout, there appears to be a negligible effect of Ni particle size on turnover rate. These results indicate the presence of structure sensitivity for methane reforming, but only with freshly calcined and reduced catalysts that may contain highly coordinatively unsaturated sites. There is an apparent structure insensitivity with aged catalysts where Ni particle sizes are generally 50 nm and greater. Under reaction conditions that employ high space velocities and low methane conversions, the water-gas-shift reaction does not establish thermodynamic equilibrium.

03 NATURAL GAS↗

The influence of the electrochemical stressing (potential step and potential-static holding) on the degradation of polymer electrolyte membrane fuel cell electrocatalysts

The understanding of the degradation mechanisms of electrocatalysts is very important for developing durable electrocatalysts for polymer electrolyte membrane (PEM) fuel cell. The degradation of Pt/C electrocatalysts under potential static holding conditions (at 1.2V and 1.4V vs. RHE) and potential step conditions with the upper potential of 1.4V for 150s and changing to lower potential limits (0.85V and 0.60V) for 30s in each period [denoted as Pstep(1.4V_150s-0.85V_30s) and Pstep(1.4V_150s-0.60V_30s), respectively] were investigated. The electrocatalysts and support were characterized with electrochemical voltammetry, transmission electron microscope (TEM) and X-ray photoelectron spectroscopy (XPS). Pt/C degrades much faster under Pstep conditions than that under potential static holding conditions. Pt/C degrades under the Pstep(1.4V_150s-0.85V_30s) condition mainly through the coalescence process of Pt nanopaticles due to the corrosion of carbon support, which is similar to that under the conditions of 1.2V and 1.4V potential static holding; however, Pt/C degrades mainly through the dissolution/loss and dissolution/redepostion process if stressed under Pstep(1.4V_150s-0.60V_30s). The difference in the degradation mechanisms is attributed to the chemical states of Pt nanoparticles: Pt dissolution can be alleviated by the protective oxide layer under the Pstep(1.4V_150s-0.85V_30s) condition and the potential static holding conditions. These findings are very important for understanding PEM fuel cell material degradation and are also useful for developing fast test method for screening durable catalyst support materials.

30 DIRECT ENERGY CONVERSION↗

Functionalized carbon nanotubes and nanofibers for biosensing applications

This review summarizes the recent advances of carbon nanotube (CNT) and carbon nanofiber (CNF)-based electrochemical biosensors with an emphasis on the applications of CNTs. Carbon nanotubes and carbon nanofibers have unique electric, electrocatalytic, and mechanical properties which make them efficient materials for the use in electrochemical biosensor development. In this article, the functionalization of CNTs for biosensors is simply discussed. The electrochemical biosensors based on CNT and their various applications, e.g., measurement of small biological molecules and environmental pollutants, detection of DNA, and immunosensing of disease biomarkers, are reviewed. Moreover, the development of carbon nanofiber-based electrochemical biosensors and their applications are outlined. Finally, some challenges are discussed in the conclusion.

59 BASIC BIOLOGICAL SCIENCES↗

Electrochemical Techniques

Sensitive and selective detection techniques are of crucial importance for capillary electrophoresis (CE), microfluidic chips, and other microfluidic systems. Electrochemical detectors have attracted considerable interest for microfluidic systems with features that include high sensitivity, inherent miniaturization of both the detection and control instrumentation, low cost and power demands, and high compatibility with microfabrication technology. The commonly used electrochemical detectors can be classified into three general modes: conductimetry, potentiometry, and amperometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗