Measured space environmental effects to LDEF during retrieval

Data gathered by the Interim Operational Contamination Monitor (IOCM) with regard to the effect of the space environment on the STS-32 Shuttle mission and on the Long Duration Exposure Facility (LDEF) are reported. IOCM measures the deposition of molecular and particulate contamination during all flight phases. It also measures the thermophysical properties of thermal control surfaces by calorimetry, the flux of the ambient atomic oxygen environment, the incident solar flux, and the absolute ambient pressure in the payload bay. The IOCM also provides a structure and sample holders for the exposure of passive material samples to the space environment. One of the more salient results from the STS-32 flight suggests that the LDEF emitted a large number of particulates after berthing into the Shuttle. The mission atomic oxygen fluence was also calculated. Although the fluence was low by normal standards, the Kapton (trademark) passive samples exhibited the onset of erosion. Orbital debris and micrometeoroid impacts also occurred during the retrieval mission. The average perforation diameter was approximately 1.25 micrometers. The largest perforation diameter was measured at 65 micrometers.

Maag, Carl R.↗

A comparison of shuttle vernier engine plume contamination with CONTAM 3.4 code predictions

In 1985, using the CONTAM 3.2 code, it was predicted that the shuttle Primary Reaction Control System (PRCS) and Vernier Reaction Control System (VRCS) engines could be potential contamination sources to sensitive surfaces located within the shuttle payload bay. Spaceflight test data on these engines is quite limited. Shuttle mission STS-32, the Long Duration Exposure Facility retrieval mission, was instrumented with an experiment that provided the design engineer with evidence that contaminant species from the VRCS engines can enter the payload bay. More recently, the most recent version of the analysis code, CONTAM 3.4, has re-examined the contamination potential of these engines.

Maag, Carl R.↗

Measured space environmental effects to LDEF during retrieval

On the STS-32 shuttle mission, a space flight experiment provided an understanding of the effects of the space environment on the Long Duration Exposure Facility (LDEF) from rendezvous with the shuttle until removal from the payload bay at the Orbiter Processing Facility (OPF) at KSC. The Interim Operational Contamination Monitor (IOCM) is an attached shuttle payload that has been used on two earlier flights (STS 51C and STS 28) to quantify the contamination deposited during the course of the mission. The IOCM can characterize by direct measurement, the deposition of molecular and particulate contamination during any phase of flight. In addition to these principal measurements, the IOCM actively measures the thermophysical properties of thermal control surfaces by calorimetry, the flux of the ambient atomic oxygen environment, the incident solar flux, and the absolute ambient pressure in the payload bay. The IOCM also provides a structure and sample holders for the exposure of passive material samples to the space environment, e.g. thermal cycling, atomic oxygen, and micrometeoroids and/or orbital debris, etc. One of the more salient results from the STS-32 flight suggests that the LDEF emitted a large number of particulates after berthing into the shuttle. The mission atomic oxygen fluence was also calculated. Although the fluence was low by normal standards, the Kapton passive samples exhibited the onset of erosion. Orbital debris and micrometeoroid impacts also occurred during the retrieval mission. The average perforation diameter was approximately 12.5 microns. The largest perforation diameter was measured at 65 microns.

Maag, Carl R.↗

Measured space environmental effects to LDEF during retrieval

The Interim Operational Contamination Monitor (IOCM) is an attached shuttle payload to the Long Duration Exposure Facility (LDEF) that was used on 2 earlier flights to quantify the contamination deposited during the course of the missions. The IOCM can characterize by direct measurement the deposition of molecular and particulate contamination during any phase of flight. Also, the IOCM actively measures the optical property changes of thermal control surfaces by calorimetry, the flux of the ambient atomic oxygen environment, the incident solar flux, and the absolute ambient pressure in the payload bay. The IOCM also provides a structure and sample holders for the exposure of passive material samples to the space environment, e.g., thermal cycling, atomic oxygen, and micrometeoroids and/or debris. Some of the more salient results from the flight suggests that the payload bay was slightly contaminated during both the prelaunch phase of the mission and after the deployment of the SYNCOM IV payload. Measurements during the postflight phases, i.e., ferry flight and deintegration processing, show negligible to very low mass deposition. The results of the data are discussed in depth.