Search NASA⌕ Search

Engineering topics

Lindner, M.

Publications and source records attributed to Lindner, M..

At least 19 records

Feasibility of enhancing carbon sequestration and stock capacity in temperate and boreal European forests via changes to management regimes

Forest management practices might act as nature-based methods to remove CO 2 from the atmosphere and slow anthropogenic climate change and thus support an EU forest-based climate change mitigation strategy. However, the extent to which diversified management actions could lead to quantitatively important changes in carbon sequestration and stocking capacity at the tree level remains to be thoroughly assessed. To that end, we used a state-of-the-science bio-geochemically based forest growth model to simulate effects of multiple forest management scenarios on net primary productivity (NPP) and potential carbon woody stocks (pCWS) under twenty scenarios of climate change in a suite of observed and virtual forest stands in temperate and boreal European forests. Previous modelling experiments indicated that the capacity of forests to assimilate and store atmospheric CO 2 in woody biomass is already being attained under business-as-usual forest management practices across a range of climate change scenarios. Nevertheless, we find that on the long-term, with increasing atmospheric CO 2 concentration and warming, managed forests show both higher productivity capacity and a larger potential pool size of stored carbon than unmanaged forests as long as thinning and tree harvesting are of moderate intensity.

54 ENVIRONMENTAL SCIENCES↗

GPU-based optical simulation of the DARWIN detector

Abstract Understanding propagation of scintillation light is critical for maximizing the discovery potential of next-generation liquid xenon detectors that use dual-phase time projection chamber technology. This work describes a detailed optical simulation of the DARWIN detector implemented using Chroma, a GPU-based photon tracking framework. To evaluate the framework and to explore ways of maximizing efficiency and minimizing the time of light collection, we simulate several variations of the conventional detector design. Results of these selected studies are presented. More generally, we conclude that the approach used in this work allows one to investigate alternative designs faster and in more detail than using conventional Geant4 optical simulations, making it an attractive tool to guide the development of the ultimate liquid xenon observatory.

Instruments & Instrumentation↗

Joint Measurement of the 235 U Antineutrino Spectrum by PROSPECT and STEREO

The PROSPECT and STEREO collaborations present a combined measurement of the pure 235 U antineutrino spectrum, without site specific corrections or detector-dependent effects. The spectral measurements of the two highest precision experiments at research reactors are found to be compatible with χ 2 /ndf = 24.1/21, allowing a joint unfolding of the prompt energy measurements into antineutrino energy. This $\bar{ν}_e$ energy spectrum is provided to the community, and an excess of events relative to the Huber model is found in the 5-6 MeV region. When a Gaussian bump is fitted to the excess, the data-model χ 2 value is improved, corresponding to a 2.4σ significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for signatures of sterile neutrinos with Double Chooz

We present a search for signatures of neutrino mixing of electron anti-neutrinos with additional hypothetical sterile neutrino flavors using the Double Chooz experiment. The search is based on data from 5 years of operation of Double Chooz, including 2 years in the two-detector configuration. The analysis is based on a profile likelihood, i.e. comparing the data to the model prediction of disappearance in a data-to-data comparison of the two respective detectors. The analysis is optimized for a model of three active and one sterile neutrino. It is sensitive in the typical mass range ${5 \times 10^{-3}}\,\mathrm{eV}^2 \lesssim \varDelta m^2_{41} \lesssim {3 \times 10^{-1}}\,\mathrm{eV}^2$ for mixing angles down to $\sin ^2 2\theta _{14} \gtrsim {0.02}$. No significant disappearance additionally to the conventional disappearance related to $\theta _{13}$ is observed and correspondingly exclusion bounds on the sterile mixing parameter $\theta _{14}$ as a function of $\varDelta m^2_{41}$ are obtained.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactor rate modulation oscillation analysis with two detectors in Double Chooz

A θ 13 oscillation analysis based on the observed antineutrino rates at the Double Chooz far and near detectors for different reactor power conditions is presented. This approach provides a so far unique simultaneous determination of θ 13 and the total background rates without relying on any assumptions on the specific background contributions. The analysis comprises 865 days of data collected in both detectors with at least one reactor in operation. The oscillation results are enhanced by the use of 24.06 days (12.74 days) of reactor-off data in the far (near) detector. The analysis considers the ${\overline{\nu}}_e$ interactions up to a visible energy of 8.5 MeV, using the events at higher energies to build a cosmogenic background model considering fast-neutrons interactions and 9 Li decays. The background-model-independent determination of the mixing angle yields sin 2 (2 θ 13 ) = 0.094 ± 0.017, being the best-fit total background rates fully consistent with the cosmogenic background model. A second oscillation analysis is also performed constraining the total background rates to the cosmogenic background estimates. While the central value is not significantly modified due to the consistency between the reactor-off data and the background estimates, the addition of the background model reduces the uncertainty on θ 13 to 0.015. Along with the oscillation results, the normalization of the anti-neutrino rate is measured with a precision of 0.86%, reducing the 1.43% uncertainty associated to the expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Double Chooz {theta}13 measurement via total neutron capture detection

Neutrinos were assumed to be massless particles until the discovery of the neutrino oscillation process. This phenomenon indicates that the neutrinos have non-zero masses and the mass eigenstates (nu(1), nu(2), nu(3)) are mixtures of their flavour eigenstates (nu(e), nu(mu), nu(tau)). The oscillations between different flavour eigenstates are described by three mixing angles (theta(12), theta(23), theta(13)), two differences of the squared neutrino masses of the nu(2)/nu(1) and nu(3)/nu(1) pairs and a charge conjugation parity symmetry violating phase delta(CP). The Double Chooz experiment, located near the Chooz Electricite de France reactors, measures the oscillation parameter theta(13) using reactor neutrinos. Here, the Double Chooz collaboration reports the measurement of the mixing angle theta(13) with the new total neutron capture detection technique from the full data set, yielding sin(2)(2 theta(13)) = 0.105 +/- 0.014. This measurement exploits the multidetector configuration, the isoflux baseline and data recorded when the reactors were switched off. In addition to the neutrino mixing angle measurement, Double Chooz provides a precise measurement of the reactor neutrino flux, given by the mean cross-section per fission <sigma(f)& rang; = (5.71 +/- 0.06) x 10(-43) cm(2) per fission, and reports an empirical model of the distortion in the reactor neutrino spectrum. The Double Chooz collaboration reports the neutrino oscillation parameter theta(13) from a measurement of the disappearance of reactor anti-electron neutrinos with the total neutron capture technique.

Djurcic, Z.↗

Cosmic-muon characterization and annual modulation measurement with Double Chooz detectors

A study on cosmic muons has been performed for the two identical near and far neutrino detectors of the Double Chooz experiment, placed at ∼120 and ∼300 m.w.e. underground respectively, including the corresponding simulations using the MUSIC simulation package. This characterization has allowed us to measure the muon flux reaching both detectors to be (3.64 ± 0.04) × 10{sup −4} cm{sup −2}s{sup −1} for the near detector and (7.00 ± 0.05) × 10{sup −5} cm{sup −2}s{sup −1} for the far one. The seasonal modulation of the signal has also been studied observing a positive correlation with the atmospheric temperature, leading to an effective temperature coefficient of α {sub T} = 0.212 ± 0.024 and 0.355 ± 0.019 for the near and far detectors respectively. These measurements, in good agreement with expectations based on theoretical models, represent one of the first measurements of this coefficient in shallow depth installations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Limit on the radiative neutrinoless double electron capture of 36 Ar from GERDA Phase I

Neutrinoless double electron capture is a process that, if detected, would give evidence of lepton number violation and the Majorana nature of neutrinos. Here, a search for neutrinoless double electron capture of 36 Ar has been performed with germanium detectors installed in liquid argon using data from Phase I of the GERmanium Detector Array (Gerda) experiment at the Gran Sasso Laboratory of INFN, Italy. No signal was observed and an experimental lower limit on the half-life of the radiative neutrinoless double electron capture of 36 Ar was established: T 1/2 > 3.6 × 10 21 years at 90% CI.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of θ 13 in Double Chooz using neutron captures on hydrogen with novel background rejection techniques

We observed a measurement of the Double Chooz collaboration and the neutrino mixing angle θ 13 using reactor $\bar{v}$ e via the inverse beta decay reaction in which the neutron is captured on hydrogen. Our measurement is based on 462.72 live days data, approximately twice as much data as in the previous such analysis, collected with a detector positioned at an average distance of 1050 m from two reactor cores. Several novel techniques have been developed to achieve significant reductions of the backgrounds and systematic uncertainties. Accidental coincidences, the dominant background in this analysis, are suppressed by more than an order of magnitude with respect to our previous publication by a multi-variate analysis. Furthermore, these improvements demonstrate the capability of precise measurement of reactor $\bar{v}$ e without gadolinium loading. Spectral distortions from the $\bar{v}$ e reactor flux predictions previously reported with the neutron capture on gadolinium events are confirmed in the independent data sample presented here. A value of sin 2 2θ 13 = 0.095 0.039 +0.038 (stat+syst) is obtained from a fit to the observed event rate as a function of the reactor power, a method insensitive to the energy spectrum shape. A simultaneous fit of the hydrogen capture events and of the gadolinium capture events yields a measurement of sin 2 2θ 13 = 0.088 ± 0.033(stat+syst).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results on $\beta \beta $ decay with emission of two neutrinos or Majorons in $^{76}$ Ge from GERDA Phase I: GERDA Collaboration

A search for neutrinoless ββ decay processes accompanied with Majoron emission has been performed using data collected during Phase I of the GERmanium Detector Array (GERDA) experiment at the Laboratori Nazionali del Gran Sasso of INFN (Italy). Processes with spectral indices n = 1,2,3,7 were searched for. No signals were found and lower limits of the order of 10 23 yr on their half-lives were derived, yielding substantially improved results compared to previous experiments with 76 Ge. A new result for the half-life of the neutrino-accompanied ββ decay of 76Ge with significantly reduced uncertainties is also given, resulting in T 2ν 1/2 = (1.926 ± 0.094) × 10 21 yr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improvement of the energy resolution via an optimized digital signal processing in GERDA Phase I

An optimized digital shaping filter has been developed for the Gerda experiment which searches for neutrinoless double beta decay in $^{76}$Ge. The Gerda Phase I energy calibration data have been reprocessed and an average improvement of 0.3 keV in energy resolution (FWHM) corresponding to 10% at the $Q$ value for $0\nu \beta \beta $0νββ decay in $^{76}$Ge is obtained. This is possible thanks to the enhanced low-frequency noise rejection of this Zero Area Cusp (ZAC) signal shaping filter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production, characterization and operation of $^{76}$Ge enriched BEGe detectors in GERDA

The GERmanium Detector Array (Gerda) at the Gran Sasso Underground Laboratory (LNGS) searches for the neutrinoless double beta decay (0νββ) of 76 Ge. Germanium detectors made of material with an enriched 76 Ge fraction act simultaneously as sources and detectors for this decay. During Phase I of theexperiment mainly refurbished semi-coaxial Ge detectors from former experiments were used. For the upcoming Phase II, 30 new 76 Ge enriched detectors of broad energy germanium (BEGe)-type were produced. A subgroup of these detectors has already been deployed in Gerda during Phase I. The present article reviews the complete production chain of these BEGe detectors including isotopic enrichment, purification, crystal growth and diode production. The efforts in optimizing the mass yield and in minimizing the exposure of the 76 Ge enriched germanium to cosmic radiation during processing are described. Furthermore, characterization measurements in vacuum cryostats of the first subgroup of seven BEGe detectors and their long-term behavior in liquid argon are discussed. Lastly, the detector performance fulfills the requirements needed for the physics goals of Gerda Phase II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗