Search NASA⌕ Search

Engineering topics

Lines, Amanda M.

Publications and source records attributed to Lines, Amanda M..

30 records · Page 2

Measuring Nd(III) Solution Concentration in the Presence of Interfering Er(III) and Cu(II) Ions: A Partial Least Squares Analysis of Ultraviolet–Visible Spectra

Optical spectroscopy is a powerful characterization tool with applications ranging from fundamental studies to real-time process monitoring. However, it can be difficult to apply to complex samples that contain interfering analytes which are common in processing streams. Multivariate (chemometric) analysis has been examined for providing selectivity and accuracy to the analysis of optical spectra and expanding its potential applications. Here we will discuss chemometric modeling with an in-depth comparison to more simplistic analysis approaches and outline how chemometric modeling works while exploring the limits on modeling accuracy. Understanding the limitations of the chemometric model can provide better analytical assessment regarding the accuracy and precision of the analytical result. This will be explored in the context of UV–Vis absorbance of neodymium (Nd 3+ ) in the presence of interferents, erbium (Er 3+ ) and copper (Cu 2+ ) under conditions simulating the liquid–liquid extraction approach used to recycle plutonium (Pu) and uranium (U) in used nuclear fuel worldwide. Finally, the selected chemometric model, partial least squares regression, accurately quantifies Nd 3+ with a low percentage error in the presence of interfering analytes and even under conditions that the training set does not describe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantification of Raman-Interfering Polyoxoanions for Process Analysis: Comparison of Different Chemometric Models and a Demonstration on Real Hanford Waste

The Hanford site represents a complicated environmental remediation challenge, remaining from the production of nuclear weapons. Over 100 million gallons of liquid radioactive waste of unknown composition will be chemically processed and vitrified, but the varying chemical composition and highly radioactive nature of the waste preclude the implementation of more developed, offline technologies to determine the composition. The only practical approach to waste treatment will require the significant utilization of real-time, chemometric modeling approaches. Although chemometric approaches have been applied to the analysis of Hanford waste, the models developed were highly tank-specialized, and limited discussion was provided on how models fared with interfering signals. As the tank waste is largely composed of oxoanions, which tend to have interfering Raman spectra, the general question was posed as to what chemometric approach is best suited to accurately quantify analytes in the presence of interfering signals. This was carried out by examining the ability of classical least square (CLS), principal component regression (PCR), partial least square (PLS), and locally weighted regression (LWR) to quantify NO 3 – and CO 3 2– using their bands around 1050 cm –1 . Finally, for all samples, the PLS-based model was found to be the most efficient approach from a model building and application perspective.

54 ENVIRONMENTAL SCIENCES↗

Raman Spectroscopy Based On-Line, Real-Time Monitoring to Reduce Composition Uncertainties: Enhanced sensitivity through optimization of Raman Parameters

Optical spectroscopy-based on-line monitoring of Hanford processing streams can enable real-time characterization of chemical composition of process streams and batches, ultimately enabling and enhancing process control. It can provide immediate feedback on process conditions and has the potential to reduce the needed number of grab sample collections, thereby reducing times and costs associated with laboratory processing. Here we discuss the utilization of Raman spectroscopy to quantify multiple target analytes that are common within Hanford tanks and waste processing streams. Analytes include: nitrate, nitrite, carbonate, chromate, sulfate, phosphate, hydroxide, oxalate, ammonia, and aluminate. Most notably in this work, Raman applications to low-concentration streams are explored and optimized. Raman instrument specifications are compared; specifically, the impact of utilizing three different Raman excitation wavelengths, 405, 532, and 671 nm, is discussed. Also, Raman data collection parameters such as collection time and spectral averaging are measured and discussed. Finally, optical libraries of chemical targets were collected using optimized collection parameters and chemometric models were built to automate quantification of chemical targets. These models were validated through application to simulants and real Hanford process samples. Chemometric models performed well on both training and validation sets, suggesting these approaches can be successfully applied to on-line and real-time monitoring of low concentration Hanford processing streams. The use of the combine Raman wave lengths with the enhanced chemometric models for the low concentration streams significantly improved the chemical detection levels and significantly reduced uncertainties of those measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Raman Spectroscopy Coupled with Chemometric Analysis for Speciation and Quantitative Analysis of Aqueous Phosphoric Acid Systems

Complex chemical systems that exhibit varied and matrix-dependent speciation are notoriously difficult to monitor and characterize on-line and in real-time. Optical spectroscopy is an ideal tool for in situ characterization of chemical species that can enable quantification as well as species identification. Chemometric modeling, a multivariate method, has been successfully paired with optical spectroscopy to enable measurement of analyte concentrations even in complex solutions where univariate methods such as Beer’s law analysis fail. Here, Raman spectroscopy is used to quantify the concentration of phosphoric acid and its three deprotonated forms during a titration. In this system, univariate approaches would be difficult to apply due to multiple species being present simultaneously within the solution as pH is varied. Locally Weighted Regression (LWR) modeling was used to determine phosphate concentration from spectral signature. LWR results, in tandem with Multivariate Curve Resolution modeling, provide direct measurement of the concentration of each phosphate species using only the Raman signal. Furthermore, results are presented within the context of fundamental solution chemistry, including Pitzer equations to compensate for activity coefficients and non-idealities associated with high ionic strength systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-Line Monitoring of Gas-Phase Molecular Iodine Using Raman and Fluorescence Spectroscopy Paired with Chemometric Analysis

Molten salt reactors (MSRs) have the potential to safely support green energy goals. However, licensing and deployment of these systems will be aided through development of new technology. This includes on-line monitoring tools for real-time compositional analysis. Of particular interest is quantifying iodine within reactor off-gas streams to support design and operational control of reactor off-gas treatment systems. Here we discuss the development of advanced Raman spectroscopy systems for the on-line analysis of I 2(g) within the gas phase. Signal response is explored with two Raman instruments utilizing a 532 nm and a 671 nm excitation source, as a function of I 2(g) pressure and temperature. Furthermore, the applicability of chemometric modeling for advanced analysis of data is explored. Raman spectroscopy paired with chemometric analysis is demonstrated to be a powerful route to analyzing I 2(g) composition within the gas phase, which lays the foundation for applications within molten salt reactor off-gas analysis and other significant chemical processes producing iodine species.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enabling Microscale Processing: Combined Raman and Absorbance Spectroscopy for Microfluidic On-Line Monitoring

Microfluidics have many potential applications including characterization of chemical processes on a reduced scale, spanning the study of reaction kinetics using on-chip liquid–liquid extractions, sample pretreatment to simplify off-chip analysis, and for portable spectroscopic analyses. The use of in situ characterization of process streams from laboratory-scale and microscale experiments on the same chemical system can provide comprehensive understanding and in-depth analysis of any similarities or differences between process conditions at different scales. A well-characterized extraction of Nd(NO 3 ) 3 from an aqueous phase of varying NO 3– (aq) concentration with tributyl phosphate (TBP) in dodecane was the focus of this microscale study and was compared to an earlier laboratory-scale study utilizing counter current extraction equipment. Here, we verify that this same extraction process can be followed on the microscale using spectroscopic methods adapted for microfluidic measurement. Concentration of Nd (based on UV–vis) and nitrate (based on Raman) was chemometrically measured during the flow experiment, and resulting data were used to determine the distribution ratio for Nd. Extraction distributions measured on the microscale were compared favorably with those determined on the laboratory scale in the earlier study. Both micro-Raman and micro-UV–vis spectroscopy can be used to determine fundamental parameters with significantly reduced sample size as compared to traditional laboratory-scale approaches. This leads naturally to time, cost, and waste reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-Induced Catalysis of Chemical Reactions

Nuclear energy is a process which achieves zero-carbon energy and heat generation that can provide a consistent electricity load to supply the grid when renewables are not available. However, on a cost per kilowatt-hour comparison, nuclear energy is more expensive than many of the renewable energy generation technologies such as wind and solar. In order to increase the economic viability of next generation nuclear reactors for energy production, generation of a secondary product such as a chemical feedstock would increase the economic viability of nuclear energy, particularly for new installations of next-generation nuclear reactors for power production. Currently, commercial nuclear reactors are primarily used for their heat to generate steam for electricity production. There is a large amount of unused energy in the form of photon and neutron radiation that could be exploited to drive chemical processes to produce feedstock materials as a secondary product of a nuclear plant. Chemical processing with radiation is not a new concept. In fact, gamma radiation is an excellent source of high energy photons to drive photochemical reactions. Dow chemical produced commercial quantities of ethyl bromide using gamma irradiation from a 60 Co source in the 1960s and 1970s because it was the most cost-effective means of production to meet the demand.5, 6 Due to the potential economic advantages, there is a new emphasis on studying feedstock production which can be enhanced by excess gamma and neutron radiation, particularly if the reaction could be monitored in real-time which is advantageous for process optimization. A model system of lignocellulose degradation under γ- radiation was chosen for this study while following the degradation products with Raman spectroscopy in real-time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Absolute Band Intensity of the Iodine Monochloride Fundamental Mode for Infrared Sensing and Quantitative Analysis

Iodine monochloride (ICl) is a gaseous off-product of molten salt reactors; monitoring this heteronuclear diatomic is of great interest for both environmental and safety purposes. In this paper we investigate the possibility of infrared monitoring of ICl by measuring the far-infrared absorption cross section of its fundamental band near 381 cm -1 . We have performed quantitative studies of the neat gas in a 20 cm cell at 25, 35, 50 and 70 oC at multiple pressures up to ~ 9 Torr and investigated the temperature and pressure dependence of the band’s infrared cross section. Quantitative measurements were problematic due to sample adhesion to the cell walls and windows as well as reactions/possible hydrolysis of ICl to form HCl gas. Effects were mitigated by measuring only the neat gas, using short measurement times and subtracting out the partial pressure of the HCl(g). The integrated band strength is shown to be temperature independent and was found to be equal to 9.1 x 10 -19 (cm 2 /molecule) cm-1. As expected, the temperature dependence of the band profile showed only a small effect over this limited temperature range. Furthermore, we have also investigated using the absorption data along with inverse least squares multivariate methods for the quantitative monitoring of ICl effluent concentrations under different scenarios using infrared (standoff) sensing and compare these results with traditional Beer’s Law (univariate) techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CoDCon Project (Final Report)

The co-decontamination (CoDCon) project was established in FY 2016 with the objectives of (a) evaluating the uncertainty in the uranium (U)/plutonium (Pu) ratio in a mixed U/Pu product from a tributyl phosphate (TBP)–based solvent extraction flowsheet, and (b) developing and demonstrating on-line optical spectroscopy for real-time monitoring of key components (e.g., Pu, U, and HNO 3 concentrations) in the process solutions. We were interested in assessing the accuracy and precision to which a specific uranium-to-plutonium (U/Pu) ratio can be achieved, which for the purposes of this project was set at a U/Pu mass ratio of 7/3. The uncertainty associated with achieving this specific target U/Pu ratio was investigated during five flowsheet tests using laboratory-scale solvent extraction equipment. In addition, optical spectroscopic techniques were incorporated into the CoDCon solvent extraction testing system, allowing real time monitoring of all input and output process streams. Two CoDCon flowsheet tests were performed in FY 2018 using a simple dissolved fuel simulant containing only U (~1 M) and Pu (~15 mM) in nitric acid (HNO 3 ; ~3 M). In FY 2019, two additional flowsheet tests were performed. For the first of these (CoDCon Run 3), the dissolved fuel simulant was similar to that used in the first two tests, with the inclusion of 1 mM neptunium (Np). The second test conducted in FY 2019 (CoDCon Run 4) used a more representative dissolved fuel simulant, including addition of non-radioactive fission product elements. A fifth CoDCon flowsheet test (CoDCon Run 5) was conducted in FY 2020, with the following additional objectives: (1) routing of the technetium (Tc) in the simulated dissolved fuel solution to the solvent extraction raffinate, and (2) routing of the Np in the simulated dissolved fuel solution to the U/Pu product. All tests used a bank of sixteen 2 cm centrifugal contactors. The tests involved first loading the solvent (30 vol% TBP dissolved in n-dodecane) with U and Pu (and Np, for Run 5), then the Pu (and Np) was stripped from the loaded solvent with a U(IV) solution (~50 mM) and the flowsheet conditions were adjusted such that some U partitioned into the Pu-containing product stream. The amount of U accompanying the Pu was monitored in real time using optical spectroscopic techniques coupled with chemometric modeling. Based on the real-time spectroscopic measurement of the U/Pu ratio, adjustments were made to the flowrate of the fresh TBP solvent phase used to scrub U from the aqueous Pu-containing product. This proved to be a very effective way to control the U/Pu mass ratio in the product. This report presents the results of the CoDCon Run 5 test. The flowsheet tested in Run 5 was substantially different than that run in the prior tests, especially the solvent loading section of the flowsheet. Two key changes were made. First, based on the objective to extract all the Np and route it with the U/Pu product, pentavalent vanadium [V(V)] was added to the feed and scrub solutions. The purpose of the V(V) was to convert all the Np to the +6 oxidation state, which is extractable by TBP. Second, a high acid (8 M HNO 3 ) scrub was added to the flowsheet to scrub the Tc from the solvent. This was followed by a low acid scrub (0.05 M HNO 3 ) to reduce the residual HNO 3 concentration in the solvent prior to the Pu stripping step. The output from the low acid scrub was collected separately, rather than routing towards the raffinate. The modifications to the solvent loading part of the flowsheet were only partially successful. The treatment with V(V) was effective at converting the Np to Np(VI). Only 1.3% of the Np remained in the raffinate solution. However, ~40% of the Np stripped out of the solvent in the low acid scrub step; nearly 20% of the Pu also was stripped from the solvent during the low acid scrub. For further development, either modifications to the flowsheet, or concentration and recycle of the low acid stream into the

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sensor Fusion: Comprehensive Real-Time, On-Line Monitoring for Process Control via Visible, Near-Infrared, and Raman Spectroscopy

On-line monitoring based on optical spectroscopy provides unprecedented insight into the chemical composition of process streams or batches. Amplifying this approach through utilizing multiple forms of optical spectroscopy in sensor fusion can greatly expand the number and type of chemical species that can be identified and quantified. This is demonstrated herein, on the analysis of used nuclear fuel recycling streams: highly complex processes with multiple target and interfering analytes. The optical techniques of visible absorbance, near infrared absorbance, and Raman spectroscopy were combined to quantify plutonium (III, IV, VI), uranium (IV, VI), neptunium (IV, V, VI), and nitric acid. Chemometric modeling was used to quantify analytes in process streams in real-time and results were successfully used to enable immediate process control and generation of a product stream at a set composition ratio. This represents a significant step forward in the ability to monitor and control complex chemical processes occurring in harsh chemical environments.

47 OTHER INSTRUMENTATION↗