Insufficient reporting of x-ray photoelectron spectroscopy instrumental and peak fitting parameters (metadata) in the scientific literature

This study was motivated by earlier observations. It is a systematic examination of the adequacy of reporting of information (metadata) necessary to understand x-ray photoelectron spectroscopy (XPS) data collection and data analysis in the scientific literature. The information for this study was obtained from papers published in three high-quality journals over a six-month period in 2019 and throughout 2021. Each paper was evaluated to determine whether the authors had reported (percentages of the papers properly providing the information are given in parentheses) the spectrometer (66%), fitting software (15%), x-ray source (40%), pass energy (10%), spot size (5%), synthetic peak shapes in fits (10%), backgrounds in fits (10%), whether the XPS data are shown in the main body of the paper or in the supporting information (or both), and whether fitted or unfitted spectra were shown (80% of published spectra are fit). The Shirley background is the most widely used background in XPS peak fitting. The Al Kα source is the most widely used x-ray source for XPS data collection. CASAXPS is the most widely used fitting program for XPS data analysis. Further, there is good agreement between the results gathered during the two years of our survey. There are some hints the situation may be improving. This study also provides a list of the information/parameters that should be reported when XPS is performed.

47 OTHER INSTRUMENTATION↗

Definition of a new (Doniach-Sunjic-Shirley) peak shape for fitting asymmetric signals applied to reduced graphene oxide/graphene oxide XPS spectra

The existence of asymmetry in X-ray photoelectron spectroscopy (XPS) photoemission lines is widely accepted, but line shapes designed to accommodate asymmetry are generally lacking in theoretical justification. Here in this work, we present a new line shape for describing asymmetry in XPS signals that is based on two facts. First, the most widely known line shape for fitting asymmetric XPS signals that has a theoretical basis, referred to as the Doniach-Sunjic (DS) line shape, suffers from a mathematical inconvenience, which is that for asymmetric shapes the area beneath the curve (above the x-axis) is infinite. Second, it is common practice in XPS to remove the inelastically scattered background response of a peak in question with the Shirley algorithm. The new line shape described herein attempts to retain the theoretical virtues of the DS line shape, while allowing the use of a Shirley background, with the consequence that the resulting line shape has a finite area. To illustrate the use of this Doniach-Sunjic-Shirley (DSS) line shape, a set of spectra obtained from varying amounts of graphene oxide (GO) and reduced GO on a patterned, heterogeneous surface are fit and discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Assessment of the frequency and nature of erroneous x-ray photoelectron spectroscopy analyses in the scientific literature

Here, this study was undertaken to understand the extent and nature of problems in x-ray photoelectron spectroscopy (XPS) data reported in the literature. It first presents an assessment of the XPS data in three high-quality journals over a six-month period. This analysis of 409 publications showing XPS spectra provides insight into how XPS is being used, identifies the common mistakes or errors in XPS analysis, and reveals which elements are most commonly analyzed. More than 65% of the 409 papers showed fitting of XP spectra. An ad hoc group (herein identified as “the committee”) of experienced XPS analysts reviewed these spectra and found that peak fitting was a common source of significant errors. The papers were ranked based on the perceived seriousness of the errors, which ranged from minor to major. Major errors, which, in the opinion of the ad hoc committee, can render the interpretation of the data meaningless, occurred when fitting protocols ignored underlying physics and chemistry or contained major errors in the analysis. Consistent with other materials analysis data, ca. 30% of the XPS data or analysis was identified as having major errors. Out of the publications with fitted spectra, ca. 40% had major errors. The most common elements analyzed by XPS in the papers sampled and researched at an online database, include carbon, oxygen, nitrogen, sulfur, and titanium. A scrutiny of the papers showing carbon and oxygen XPS spectra revealed the classes of materials being studied and the extent of problems in these analyses. As might be expected, C 1s and O 1s analyses are most often performed on sp2-type materials and inorganic oxides, respectively. These findings have helped focus a series of XPS guides and tutorials that deal with common analysis issues. The extent of problematic data is larger than the authors had expected. Quantification of the problem, examination of some of the common problem areas, and the development of targeted guides and tutorials may provide both the motivation and resources that enable the community to improve the overall quality and reliability of XPS analysis reported in the literature.

Major, George H.↗

Proliferation of Faulty Materials Data Analysis in the Literature

As a group of subject matter experts in X-ray photoelectron spectroscopy (XPS), we write this letter to raise awareness of the epidemic of poor and incorrect materials data analysis in the Literature. This is a chronic and growing problem with very undesirable consequences. This issue may contribute to what has been identified as a “reproducibility crisis”1,2 that was the subject of a recent U.S. National Academies study. We are using XPS as one example of what we observe to be a systemic issue.

36 MATERIALS SCIENCE↗

Plotting XPS Narrow Scans (and other Data) with MATLAB’s Powerful Plotting Capabilities, 2. An Introduction to Handle Graphics

The graphical representation of numerical data plays a vital role in chemistry, materials science, and every other scientific field. No matter how good your results are, poorly represented data can ultimately make your work confusing. Indeed, with an increase in the amount of data that is being gathered, e.g., by the Materials Genome Initiative, or in X-ray photoelectron spectroscopy (XPS) or time-of-flight secondary ion mass spectrometry (ToF-SIMS) depth profiles, the importance of effectively representing data has increased. Good figures also matter because many researchers will not look at more than the title, abstract, and perhaps a few key figures from a paper.

42 ENGINEERING↗

Plotting XPS Narrow Scans (and Other data) with MATLAB, 1. Using the 'plot' and 'subplot' functions.

As researchers, we often focus more on data collection than data work-up. However, skillfully plotting data so that it can be effectively visualized is often an important step toward making it impactful. Data visualization in academic writing takes the form of plots, figures, graphs, spectra, etc., which are often combined with cartoons and schematics. An important goal of data visualization is to make complex data and concepts more accessible, understandable, and usable, and to do this in a concise manner – ‘a picture is worth a thousand words’ as the old cliché goes. Data visualization is both art and science, where, of course, data visualization depends on the type of data in question. Herein, we discuss ways of representing/plotting data using MATLAB from the MathWorks ® .

97 MATHEMATICS AND COMPUTING↗

Practical guides for x-ray photoelectron spectroscopy: First steps in planning, conducting, and reporting XPS measurements

Over the past three decade the use of XPS in research and publications has grown to make XPS the most widely used surface analysis method. Associated with the increased use there is an increase in new or inexperienced users along with a increase in erroneous and misapplications of the method. This article is the first in a series of guides and tutorials assembled by a committee of experienced practitioners intended to assist inexperienced users by sharing information about good practices in the use of XPS. This first guide identifies some sources of information for learning how to conduct XPS studies and examines the types of questions to be asked when determining if XPS is an appropriate technique to provide the needed or desired information. Many of the topics/questions addressed in this article apply to the other surface analysis techniques as well.

47 OTHER INSTRUMENTATION↗

Physical and optical properties of the International Simple Glass

Abstract Radioactive waste immobilization is a means to limit the release of radionuclides from various waste streams into the environment over a timescale of hundreds to many thousands of years. Incorporation of radionuclide-containing wastes into borosilicate glass during vitrification is one potential route to accomplish such immobilization. To facilitate comparisons and assessments of reproducibility across experiments and laboratories, a six-component borosilicate glass (Si, B, Na, Al, Ca, Zr) known as the International Simple Glass (ISG) was developed by international consensus as a compromise between simplicity and similarity to waste glasses. Focusing on a single glass composition with a multi-pronged approach utilizing state-of-the-art, multi-scale experimental and theoretical tools provides a common database that can be used to assess relative importance of mechanisms and models. Here we present physical property data (both published and previously unpublished) on a single batch of ISG, which was cast into individual ingots that were distributed to the collaborators. Properties from the atomic scale to the macroscale, including composition and elemental impurities, phase purity, density, thermal properties, mechanical properties, optical and vibrational properties, and the results of molecular dynamics simulations are presented. In addition, information on the surface composition and morphology after polishing is included. Although the existing literature on the alteration of ISG is not extensively reviewed here, the results of well-controlled static alteration experiments are presented here as a point of reference for other performance investigations.

36 MATERIALS SCIENCE↗

Tutorial on interpreting x-ray photoelectron spectroscopy survey spectra: Questions and answers on spectra from the atomic layer deposition of Al 2 O 3 on silicon

X-ray photoelectron spectroscopy (XPS) has become the most widely used method for chemically analyzing surfaces. In XPS, photoelectrons are generated by irradiating a surface with X-rays. As the importance and popularity of XPS have grown, it has drawn users without significant XPS experience, and incorrect and incomplete interpretations of XPS spectra regularly appear in the literature. This tutorial is designed as a tool to guide less experienced users in analyzing XPS survey spectra. Here, we examine a series of XPS survey spectra collected during the atomic layer deposition of Al2O3 from trimethylaluminum and water precursors. Prior to this, brief explanations of XPS and atomic layer deposition (ALD) are presented. This tutorial is structured as a series of questions and answers that the interested reader may choose to engage in. The XPS spectra are scrutinized to extract information about the elements present in the film, the presence of contamination, and the nature of the film growth process. The questions and answers in this tutorial address important fundamental issues common to the interpretation of many XPS survey spectra in the context of ALD.

XPS spectrum, Tutorial, Atomic layer deposition↗

Assigning Oxidation States to Organic Compounds via Predictions from X-ray Photoelectron Spectroscopy: A Discussion of Approaches and Recommended Improvements

The traditional assignment of oxidation numbers to organic molecules is problematic. Accordingly, in 1999, Calzaferri proposed a simple and elegant solution that is based on the similar electronegativities of carbon and hydrogen: hydrogen would be assigned an oxidation number of zero when bonded to carbon. Here we show that X-ray photoelectron spectroscopy (XPS), a core electron spectroscopy that is sensitive to oxidation states of elements, confirms his suggestion. In particular, in this work we: (i) list the typical rules for assigning oxidation numbers, (ii) discuss the traditional assignment of oxidation numbers to organic molecules, (iii) review Calzaferri’s solution, (iv) introduce X-ray photoelectron spectroscopy (XPS), (v) show the consistency of Calzaferri’s suggestion with XPS results, (vi) provide supporting examples from the literature, (vii) provide examples from our own research, and (viii) further confirm the Calzaferri suggestion/photoelectron spectroscopy results by discussing two organic well-known reactions. We end by reechoing Calzaferri’s suggestion that the traditional rules for assigning oxidation numbers to organic molecules be modified.

Environmental Molecular Sciences Laboratory↗

Silicon (100)/SiO2 by XPS

Silicon (100) wafers are ubiquitous in microfabrication and, accordingly, their surface characteristics are important. Herein, we report the analysis of Si (100) via X-ray photoelectron spectroscopy (XPS) using monochromatic Al K radiation. Survey scans show that the material is primarily silicon and oxygen, and the Si 2p region shows two peaks that correspond to elemental silicon and silicon dioxide. Using these peaks the thickness of the native oxide (SiO2) was estimated using the equation of Strohmeier.1 The oxygen peak is symmetric. The material shows small amounts of carbon, fluorine, and nitrogen contamination. These silicon wafers are used as the base material for subsequent growth of templated carbon nanotubes.

Environmental Molecular Sciences Laboratory↗

Al2O3 e-Beam Evaporated onto Silicon (100)/SiO2, by XPS

We report the XPS characterization of a thin film of Al2O3 (35 nm) deposited via e-beam evaporation onto silicon (100). The film was characterized with monochromatic Al Ka radiation. An XPS survey scan, an Al 2p narrow scan, and the valence band spectrum were collected. The Al2O3 thin film is used as a diffusion barrier layer for templated carbon nanotube (CNT) growth in the preparation of microfabricated thin layer chromatography plates.

Environmental Molecular Sciences Laboratory↗

Multiwalled Carbon Nanotube Forest Grown via Chemical Vapor Deposition from Iron Catalyst Nanoparticles, by XPS

Carbon nanotubes (CNTs) have unique chemical and physical properties. Herein, we report an XPS analysis of a forest of multiwalled CNTs using monochromatic Al Kα radiation. Survey scans show only one element: carbon. The carbon 1s peak is centered 284.5 eV. The C 1s envelope also shows the expected π → π* shake-up peak at ca. 291 eV. The valence band and carbon KVV Auger signals are presented. When patterned, the CNT forests can be used as a template for subsequent deposition of metal oxides to make thin layer chromatography plates.1-3

Jensen, David S.↗

Carbon/Ternary Alloy/Carbon Optical Stack on Mylar as an Optical Data Storage Medium to Potentially Replace Magnetic Tape

A novel write-once-read-many (WORM) optical stack on Mylar tape is proposed as a replacement for magnetic tape for archival data storage. This optical tape contains a cosputtered bismuth–tellurium–selenium (BTS) alloy as the write layer sandwiched between thin, protective films of reactively sputtered carbon. The composition and thickness of the BTS layer were confirmed by Rutherford Backscattering (RBS) and atomic force microscopy (AFM), respectively. The C/BTS/C stack on Mylar was written to/marked by 532 nm laser pulses. Under the same conditions, control Mylar films without the optical stack were unaffected. Marks, which showed craters/movement of the write material, were characterized by optical microscopy and AFM. The threshold laser powers for making marks on C/BTS/C stacks with different thicknesses were explored. Higher quality marks were made with a 60× objective compared to a 40× objective in our marking apparatus. Finally, the laser writing process was simulated with COMSOL.

Environmental Molecular Sciences Laboratory↗

Thermally Evaporated Iron (Oxide) on an Alumina Barrier Layer, by XPS

We report the XPS characterization of a thermally evaporated iron thin film (6 nm) deposited on an Si/SiO_2/Al_2O_3 substrate using Al Ka X-rays. An XPS survey spectrum, narrow Fe 2p scan, narrow O 1s, and valence band scan are shown.

Environmental Molecular Sciences Laboratory↗

Thermally Annealed Iron (Oxide) Thin Film on an Alumina Barrier Layer, by XPS

Herein we show characterization of an Fe thin film on Al_2O_3 after thermal annealing under H_2 using Al Ka X-rays. The XPS survey spectrum, narrow Fe 2p scan, and valence band regions are presented. The survey spectrum shows aluminum signals due to exposure of the underlying Al_2O_3 film during Fe nanoparticle formation.