An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because they can aid in both cybersecurity analysis and the evaluation of cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

alfalfa↗

A Cybersecurity Testbed for Smart Buildings

Smart buildings are equipped with a plethora of cyber-physical systems, such as Internet of Things (IoT) devices and building automation systems. These devices, especially in commercial buildings, use legacy communications and hardware that were not designed with cybersecurity in mind. With increasing cyber threats in recent years, smart buildings have become an increasing target for attacks, but not enough published data are available from these incidents to study or replicate the scenarios to defend buildings. As part of the U.S. Department of Energy-funded project focusing on developing the Building Intelligence with Layered Defense Using Security-Constrained Optimization and Security Risk Detection (BUILD-SOS) platform, we developed a cybersecurity test bed for smart buildings. This test bed includes a building simulation tool, virtual devices, emulated operational technology networks, and remote hardware-in-the-loop. Using this test bed, we performed different cyberattacks on the smart building model and collected both physical building data, to understand the impacts on the building, and network data, to aid in separating mechanical faults from cyberattacks during the detection. This test bed is a significant tool in protecting smart buildings from cyberattacks because it can aid in both cybersecurity analysis and the evaluation of other cyberattack detection tools by testing the tools in a secure environment without impacting the building operations.

cyber-physical systems↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

A framework of stress analysis and fatigue analysis was developed. Utilizing the framework, stress analysis and fatigue analysis of high-performance heat exchangers with non-round shaped tubes were studied. The tubes, headers and welding layers were studied separately before analyzing the assembled heat exchangers. Results reveal different stress strength on the different shapes of tubes and headers. Unevenly welding distribution is also discussed in the report. Moreover, the fatigue analysis results of the heat exchanger are helping to estimate the lifetime of the heat exchanger from fatigue point of view.

42 ENGINEERING↗

Designing for Zero Energy and Zero Carbon on a Multi-Building Scale Using URBANopt: Preprint

Groundbreaking efforts are necessary to mitigate contributors increasing impacts of climate change. In parallel to inventing pioneering clean energy technologies it is even more fundamental to rethink designing energy systems within a singular facility and collectively to function as a district. Facilities should not be continuously passive by just consuming; there is a need to shift to perform more dynamically. Designing for zero energy and zero carbon on a multi-building scale can uncover opportunities for building energy efficiency, decarbonization, demand flexibility, and resiliency that are not accessible at an individual building scale. This approach can be challenging without innovative tools to evaluate the multitude of possibilities. As an investigated result, we highlight the use of a campus-scale energy modeling platform - URBANopt™ - for the expansion of the National Renewable Energy Laboratory's (NREL's) South Table Mountain campus in Golden, Colorado. Programmatic growth included the design of three new all-electric, zero-energy, and zero-carbon, mixed used buildings (a combination of research laboratories and office space). This investigation is critical to NREL reaching net-zero emissions for its operational footprint, which will occur in phases over the next decade. Leveraging URBANopt's capabilities, we evaluate 1) high-performance building energy efficiency and decarbonization measures, 2) 4th generation district heating and cooling (4th GDHC) systems, 3) optimized onsite generation and energy storage assets that meet zero-energy and zero-carbon targets at minimum life-cycle costs, and 4) cost-optimal distributed energy technology mixes, dispatch strategies, and associated capacities that increase resiliency to grid outages. This work demonstrates the use and capabilities of URBANopt through a real-world case study on a multi-building scale.

community energy model↗

LBNL Fault Detection and Diagnostics Datasets

These datasets can be used to evaluate and benchmark the performance accuracy of Fault Detection and Diagnostics (FDD) algorithms or tools. It contains operational data from simulation, laboratory experiments, and field measurements from real buildings for seven HVAC systems/equipment (rooftop unit, single-duct air handler unit, dual-duct air handler unit, variable air volume box, fan coil unit, chiller plant, and boiler plant). Each dataset includes a .pdf file to document key information necessary to understand the content and scope, multiple csv files containing all the time-series data for faults at different severity levels and one fault-free case, and a ttl file to visualize the data according to BRICK schema. The dataset was created by LBNL, PNNL, NREL, ORNL and Drexel University.

AC↗

Multi-scale and multi-physics analysis, design optimization, and experimental validation of heat exchangers utilizing high performance, non-round tubes

Air-to-refrigerant heat exchangers (HXs) are fundamental components in HVAC&R systems, and considerable research has been dedicated designing continually smaller, lighter, and more efficient HX designs. In recent years, researchers have leveraged advancements in Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA), and optimization algorithms to consider primary tube shape and topology optimization to design highly compact, high performance HXs for a multitude of applications. In this research, we present a computationally efficient, comprehensive, multi-scale, and multi-physics analysis and optimization method for air-to-refrigerant HXs featuring automated CFD and FEA simulations and approximation-assisted optimization. This methodology was utilized to design HXs with shape-optimized, non-round tubes which outperform current state-of-the-art tube-fin HXs without compromising structural integrity. The optimal HXs were shown to deliver similar thermal performance to the baseline HXs while also achieving more than 20% reductions in airside pressure drop and core envelope volume and more than 30% reduction in internal volume. Comprehensive experimental validation of the optimization methodology was conducted through the testing of two prototypes in a standardized wind tunnel facility under multiple operating conditions. For prototype #1 under dry evaporator conditions, the predicted heat load agreed within ± 10% of measured values and the predicted airside pressure drop agreed within ± 30%, while for dehumidifying conditions, the predicted sensible and latent heat loads agreed within ± 10% and ± 20% of the measured values, respectively. For prototype #2, the predicted condenser heat load agreed within ± 3.0% of measured values, and the predicted airside pressure drop agreed within ± 27%. The acceptable agreement between simulation and experimental results for the present application highlights the flexibility of the novel optimization methodology to design next generation HXs with improved performance and reduced volume, weight, and environmental impact.

42 ENGINEERING↗

Development and Validation of Resistance-Capacitance Model for Phase Change Material Embedded in Porous Media

A simple and effective way to enhance PCM thermal conductivity is by embedding porous materials with high thermal conductivities. In this work, CFD was used to evaluate the melting of PCM embedded in metal foam supplied with constant heat flux. Good agreement between experimental and numerical results has been found with a mean PCM local temperature deviation of 1.62K and 2.97K in two locations. The CFD simulation time was 56 hours for 6.5 hours of flow time. A computationally efficient resistance capacitance-based model (RCM) was developed to improve simulation speed. The proposed RCM exhibited mean local temperature deviations of 1.86K and 2.96K when compared against the experimental data for two thermocouple positions, however, it was approximately 2.5x10 5 times faster than CFD. The charging time deviation was less than 1% compared to CFD, and no significant change in thermal energy stored was observed since the temperature differences were small enough to result in insignificant sensible heat deviation. A simulation cost-effectiveness index (CEI) considering accuracy and computational affordability was introduced; the CEI of the RCM solver is 10 3 times better compared to CFD for the prediction of local PCM temperature.

25 ENERGY STORAGE↗

Effect of Thermal Expansion Coefficient, Viscosity and Melting Range in Simulation of PCM Embedded Heat Exchangers With and Without Fins

Phase change material heat exchangers (PCMHX) have an important role in integrating renewable energy systems. PCMHX can offer high storage density at various temperatures of interest and can be used for grid load shifting purposes. Numerical models enable engineers to estimate PCMHX performance for different design parameters and operating conditions. Modeling phase change phenomena is challenging due to the complex time-dependent nature of the process. The accuracy of models is highly sensitive to PCM thermo-physical properties. Thermal expansion coefficient (β), viscosity (μ) and melting temperature range (MR) of a PCM are important properties, especially when natural convection is not negligible. In PCMHX modeling, using less than accurate values for these properties can have significant impact on the simulation outcomes. These properties and discussions thereof are not readily available in the literature. This paper presents a brief review of the literature and a numerical study investigating the model sensitivity to the above-mentioned properties for PCMHX with and without fins. CFD is used to evaluate the charging (melting) phenomena. The study quantifies the impact of uncertainty in these properties on the melting rate and temperature profile. Constant wall temperature was considered as heat source with no heat loss to ambient. Here, the results show that β and μ has significant effect on the melting rate and evolution of the melting front. For a non-finned domain when comparing results for different published values of β and μ, the deviation in melting time can be up to 12.9% and 57.6% respectively. For high wall temperatures, change in melting range did not impact melting time. But when the wall temperature is reduced, up to 9.8% deviation in melting time is observed.

CFD↗

Experimental Investigation of a Phase Change Material Charged Finned-Tube Heat Exchanger

Understanding different thermal performance aspects of phase change material heat exchangers (PCM-HX) is critical for designing future energy-efficient thermal energy storage systems. This paper presents an experimental performance analysis of a vertically oriented annular finned-tube PCM-HX in a cylindrical container tested under six different melting and solidification test conditions, varied by heat transfer fluid’s (HTF) inlet temperatures and flow directions. The PCM-HX structure with 20 evenly spaced fins was 3D printed in aluminum, and the PCM-HX container was 285 mm in height. The PCM-HX average porosity was 89.7%, where the PCM mass was 246.4 g. Water served as the HTF, and a PCM with a nominal phase change temperature of 35 °C was selected. Instead of opaque conventional insulation sheets, a combination of air-and-argon-filled see-through insulation cylinders was assembled with the PCM-HX to visualize the phase-change phenomena, while minimizing the uncertainties due to heat loss. In total, there were 78 T-type thermocouples installed in the test section which allows a more precise assessment of thermal mass and heat loss, which are often neglected in similar studies found in the literature. We validated the reliability of the test facility as the repeated test results had negligible deviations under the same test conditions. The energy balances between the estimated theoretical and experimentally calculated PCM storage, considering heat loss and thermal mass, were within ±9% deviation for all test conditions. From the experimental investigations, we made several following observations. It was found that the melting pattern of the finned-tube PCM-HX with small gaps between the container wall and the fins was largely affected by the HTF flow directions, unlike the typical straight annular tube PCM-HX. For effective charging and discharging processes, a combination of upward melting and downward solidification is recommended to shorten the test duration. However, an upward solidification should be considered to minimize the cavity formation between the fins caused by the PCM volume contraction during the solidification process.

25 ENERGY STORAGE↗

Experimental Investigation of Melting and Solidification Processes of Phase Change Material Heat Exchanger

Rapid development and validation of PCM embedded heat exchangers (PCM-HX) concepts warrant a purpose-built test bench. This paper describes a test facility built for testing various PCM-HX configurations and phase change temperatures that will serve to validate the performance of novel PCM-HX designs. The entire test rig is placed in a temperature-controlled environmental chamber. Inside the PCM-HX containers, up to 48 T-type thermocouples can be spatially distributed on and around the tubes depending on the HX type to capture the phase change process over time. In this paper, a straight tube embedded in PCM having a phase change temperature of 37°C in cylindrical containers is tested. The PCM-HX uses water as an in-tube working fluid. Based on the measured data, the energy balance is analyzed, and its temperature distribution is presented. Here, the maximum deviation between the predicted stored energy and the energy stored calculated from experimental measurements is less than 5%.

36 MATERIALS SCIENCE↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Automated Parameterized CFD Simulations of Phase-Change Material Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers is typically computationally intensive due to the relative complex time-dependent underlying physics. This paper presents a study investigating a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 37oC nominal melting temperature, leveraging automated parametric CFD simulations. The computational domain is reduced to 2D axisymmetric for a segment of the HX comprising a region in between two fins with constant wall temperature as boundary condition. This approach allows for faster evaluations of the transient thermal characteristics for a given design space of interest. Correlations and reduced order models (ROM’s) are developed. Results indicate that the ROM’s reproduce the CFD simulations with high accuracy for designs from the training data set, however, designs from cross-validation and test sets do not always have good agreement. The limited number of designs in the training set is a possible cause for the lack of robustness of the ROM’s and thus additional training designs will be added in future work. The ROM’s solve the simulations on average 500,000 times faster than CFD.

25 ENERGY STORAGE↗

Numerical Study and Validation of Melting and Solidification in PCM Embedded Heat Exchangers with Straight Tube

Latent heat thermal energy storage (LHTES) systems have shown great potential to enable reliable use of renewable energy and load shifting. LHTES offer high storage density and release energy at near constant temperature because of its use of phase change materials (PCMs). The cylindrical PCM heat exchangers (PCMHX) are one of the most used technologies due to their simplicity. Numerical models for such PCMHX enable engineers to estimate their performance for different design parameters and operating conditions without having to test them all. However, modeling the phase change phenomena can be challenging. To better understand the difficulties involving accurate modeling of PCMHX, a cylindrical latent storage unit filled with PCM and water as in-tube heat transfer fluid (HTF) is numerically investigated. This paper presents a study based on a 2D-axisymmetric model of a straight tube embedded in PCM in a cylindrical container. CFD is used to study the charging (melting) and discharging (solidification) phenomena. The models are validated against experimental and numerical data from the literature. The predicted local PCM temperature profile over time agrees within 2K compared to the experimental values. The paper also presents a simple method to estimate the melting and solidification phase change temperature range from limited data provided by PCM manufacturers.

PCM, melting, solidification, CFD, heat exchanger↗

A Study on Computational Cost Reduction of Simulations of Phase-Change Material (PCM) Embedded Heat Exchangers

Thermal storage can be implemented using Phase-Change Materials (PCM), which absorb significant latent heat with a relatively small temperature change. PCM phase-change processes are transient and are driven by thermal diffusion and natural convection – the latter, especially for melting process. Modeling and simulation of PCM heat exchangers (HX’s) is typically computationally intensive due to the relatively complex time-dependent physics. Most of the PCM modeling work in the literature uses high-order modeling tools such as Computational Fluid Dynamics (CFD) and Lattice-Boltzmann Method (LBM). For design purposes, the existing PCM modeling approaches are not practical, limiting researchers in their ability to investigate new ideas and different PCM’s with faster turnarounds. This paper presents a study investigating the reduction of computational cost of PCM embedded HX’s CFD models by evaluating the feasibility of spatial reduction without losing accuracy. The analysis consists of comparing full and partial domain under full melting conditions. The subject of this study is a single straight tube with circular transverse fins in the vertical orientation, using PCM’s with 35oC nominal melting temperature. Different tube and fin dimensions are investigated. Results indicate that the reduced domain reproduces - in half the run time - the same behavior as the full domain since the buoyancy effects are localized and patterned. The outputs from the partial domain simulation were used to build a non-general correlation for the PCM heat transfer characteristics and demonstrated how it can be implemented in a Finite Control Volume Reduced Order Model (ROM). The ROM can accurately reproduce the CFD simulations at 4 to 5 orders of magnitude faster.

25 ENERGY STORAGE↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗