Search NASA⌕ Search

Engineering topics

Lintereur, Azaree T.

Publications and source records attributed to Lintereur, Azaree T..

The Evaluation of Machine Learning Techniques for Isotope Identification Contextualized by Training and Testing Spectral Similarity

Precise gamma-ray spectral analysis is crucial in high-stakes applications, such as nuclear security. Research efforts toward implementing machine learning (ML) approaches for accurate analysis are limited by the resemblance of the training data to the testing scenarios. The underlying spectral shape of synthetic data may not perfectly reflect measured configurations, and measurement campaigns may be limited by resource constraints. Consequently, ML algorithms for isotope identification must maintain accurate classification performance under domain shifts between the training and testing data. To this end, four different classifiers (Ridge, Random Forest, Extreme Gradient Boosting, and Multilayer Perceptron) were trained on the same dataset and evaluated on twelve other datasets with varying standoff distances, shielding, and background configurations. A tailored statistical approach was introduced to quantify the similarity between the training and testing configurations, which was then related to the predictive performance. Wilcoxon signed-rank tests revealed that the OVR-wrapped XGB significantly outperformed the other algorithms, with confidence levels of 99.0% or above for the 133Ba, 60Co, 137Cs, and 152Eu sources. The findings from this work are significant as they outline techniques to promote the development of robust ML-based approaches for isotope identification.

domain adaptation↗

A novel methodology for gamma-ray spectra dataset procurement over varying standoff distances and source activities

The adoption of machine learning approaches for gamma-ray spectroscopy has received considerable attention in the literature. Many studies have investigated the deployment of various algorithm architectures to a specific task. However, little attention has been afforded to the development of the datasets leveraged to train the models. Such training datasets typically span a set of environmental or detector parameters to encompass a problem space of interest to a user. Variations in these measurement parameters will also induce fluctuations in the detector response, including expected pile-up and ground scatter effects. Fundamental to this work is the understanding that 1) the underlying spectral shape varies as the measurement parameters change and 2) the statistical uncertainties associated with two spectra impact their level of similarity. While previous studies attribute some arbitrary discretization to the measurement parameters for the generation of their synthetic training data, this work introduces a principled methodology for efficient spectral-based discretization of a problem space. A signal-to-noise ratio (SNR) respective spectral comparison measure and a Gaussian Process Regression (GPR) model are used to predict the spectral similarity across a range of measurement parameters. This innovative approach effectively showcased its capability by dividing a problem space, ranging from 5 cm to 100 cm standoff distances and 5 μCi–100 μCi of 137 Cs, into three unique combinations of measurement parameters. The findings from this work will aid in creating more robust datasets, which incorporate many possible measurement scenarios, reduce the number of required experimental test set measurements, and possibly enable experimental training data collection for gamma-ray spectroscopy.

data science↗

Effects of Correlated and Uncorrelated Gamma Rays on Neutron Multiplicity Counting

Neutron multiplicity counting relies on time correlation between neutron events to assay the fissile mass, (α,n) to spontaneous fission neutron ratio, and neutron self-multiplication of samples. Gamma-ray sensitive neutron multiplicity counters may misidentify gamma rays as neutrons and therefore miscalculate sample characteristics. Time correlated and uncorrelated gamma-ray-like signals were added into gamma-ray free neutron multiplicity counter data to examine the effects of gamma ray signals being misidentified as neutron signals on assaying sample characteristics. Multiplicity counter measurements with and without gamma-ray-like signals were compared to determine the assay error associated with gamma-ray-like signals at various gamma-ray and neutron rates. Correlated and uncorrelated gamma-ray signals each produced consistent but different measurement errors. Correlated gamma-ray signals most strongly led to fissile mass overestimates, whereas uncorrelated gamma-ray signals most strongly lead to (α,n) neutron overestimates. Gamma-ray sensitive neutron multiplicity counters may be able to account for the effects of gamma-rays on measurements to mitigate measurement uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel muon detector for borehole density tomography

Muons can be used to image the density of materials through which they pass, including geological structures. Subsurface applications of the technology include tracking fluid migration during injection or production, with increasing concern regarding such timely issues as induced seismicity or chemical leakage into aquifers. Current density monitoring options include gravimetric data collection and active or passive seismic surveys. One alternative, or complement, to these methods is the development of a muon detector that is sufficiently compact and robust for deployment in a borehole. Such a muon detector can enable imaging of density structure to monitor small changes in density – a proxy for fluid migration – at depths up to 1500 m. Such a detector has been developed, and Monte Carlo modeling methods applied to simulate the anticipated detector response. Testing and measurements using a prototype detector in the laboratory and shallow underground laboratory demonstrated robust response. Lastly, a satisfactory comparison with a large drift tube-based muon detector is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-10 Based Neutron Coincidence Counter for Safeguards

The shortage of 3He has triggered the search for effective alternative neutron detection technologies for national security applications, including international nuclear safeguards. Any alternative neutron detection technology must satisfy two basic criteria: it must meet a neutron detection efficiency requirement, and it must be insensitive to gamma-ray interference at a prescribed level while still meeting the neutron detection requirement. For nuclear safeguards, a system must perform measurements in the field with a prescribed precision in a specified time. This paper describes an effort to design, model and test an alternatives-based neutron coincidence counter for nuclear safeguards applications. The technology chosen for use in an alternatives-based uranium neutron coincidence collar was boron-lined proportional counters. Extensive modeling was performed of various system configurations and comparisons were made to measurements on a commercial prototype boron-10 based uranium neutron coincidence collar.

alternative neutron detectors↗

Final Technical Report for the Neutron Detection without Helium-3 Project

This report details the results of the research and development work accomplished for the ‘Neutron Detection without Helium-3’ project conducted during the 2011-2013 fiscal years. The primary focus of the project was to investigate commercially available technologies that might be used in safeguards applications in the relatively near term. Other technologies that are being developed may be more applicable in the future, but were outside the scope of this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-10 ABUNCL Models of Fuel Testing

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Coincidence Counting With Boron-Based Alternative Neutron Detection Technology at Pacific Northwest National Laboratory (PNNL) for the development of a 3He proportional counter alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a system based upon 10B-lined proportional tubes in a configuration typical for 3He-based coincidence counter applications. This report provides results from MCNP simulations of the General Electric Reuter-Stokes Alternative Boron-Based Uranium Neutron Coincidence Collar (ABUNCL) active configuration model with fuel pins previously measured at Los Alamos National Laboratory. A comparison of the GE-ABUNCL simulations and simulations of 3He based UNCL-II active counter (the system for which the GE-ABUNCL was targeted to replace) with the same fuel pin assemblies is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Boron-10 ABUNCL Active Testing

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Coincidence Counting With Boron-Based Alternative Neutron Detection Technology at Pacific Northwest National Laboratory (PNNL) for the development of a 3 He proportional counter alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a system based upon 10 B-lined proportional tubes in a configuration typical for 3 He-based coincidence counter applications. This report provides results from testing of the active mode of the General Electric Reuter-Stokes Alternative Boron-Based Uranium Neutron Coincidence Collar (ABUNCL) at Los Alamos National Laboratory using sources and fuel pins.

Boron Based Detector↗