FY-24 Progress on Computational Modeling of the Water Based NSTF

This report summarizes the computational modeling of the Natural Convection Shutdown Heat Removal Test Facility (NSTF) completed in FY24. This year’s modeling campaign focuses on the continual testing of the RELAP5 model against experimental data. Several fault cases were simulated with the RELAP5 model in FY23 to study the accuracy of the model under complex flow conditions. Similarly, in FY24, a case is simulated where the chimney outlet is throttled with a valve while the flow is undergoing two-phase oscillations. The purpose of this case is to study the effects of increasing pressure drop in the two-phase region on the system behavior. Even though the model is able to capture the experimental data qualitatively, it overpredicts the pressure drops experienced by the flow in the two-phase regime. Nevertheless, the model and the experiment show that oscillations are stabilized with increased pressure drop in the two-phase region.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Effect of inlet throttling on thermohydraulic instability in a large scale water-based RCCS: An experimental study

The objective of the present experimental study is to investigate the effect of inlet throttling on the thermohydraulic stability of a large scale water-based Reactor Cavity Cooling System (RCCS). The test was performed using the water-based Natural convection Shutdown heat removal Test Facility (NSTF) at Argonne, which represented a ½ axial scale and 12.5° sector slice of the full scale Framatome 625 MW t SC-HTGR RCCS concept. A two-phase steady state was first established through direct condensate refill, followed by increased inlet throttling over 10 stages, corresponding to a loss coefficient K over the range of 0.05–653. With the inlet throttling gradually increased, the system experienced a unique transition process between stabilization and destabilization. Through a stability analysis, three instability mechanisms were identified in the present test, including a compound mechanism due to both natural circulation oscillations (NCOs) and density wave oscillations (DWOs), Type-II DWOs, and geysering.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period April 2023 – September 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This fourth semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY23. As a part of the RCCS design task, recent efforts have been made to complete a conceptual design of the RCCS for the HC-HTGR, including the design update of the water panel and system configuration favorable in point of view of fabrication and system operation. Design calculations were conducted under various heat load conditions to validate the system design. Transient simulations using RELAP5-3D were conducted to investigate system dynamics under transients of interest and to evaluate the system performance in the design condition. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat sink. In the primary system thermal hydraulics task, the preliminary analysis was performed for a long term pressurized conduction cooldown (PCC) transient. This analysis used a combination of a fully resolved and coarse homogenized mesh to predict the temperature distribution for the steady-state initial condition and the PCC transient. The steady-state initial condition was determined using a fully resolved full core model with 3D solid to 1D fluid coupling. The fully resolved mesh was also used to model the first 20 seconds of the PCC. The temperature difference between fuel pins and the graphite matrix becomes minimal and the dominant heat transfer shifts to a larger scale radially towards the RCCS. After 20 seconds, a homogenized coarse mesh is used, greatly reducing the computational costs of the model. These results demonstrate that the core is designed to passively remove enough decay heat in a protected loss of primary coolant flow to prevent an unsafe rise of core temperatures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Conceptual Design of the Reactor Cavity Cooling System for the Horizontal Compact High Temperature Gas Reactor (HC-HTGR)

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the design study to derive a conceptual design study of the RCCS for the HC-HTGR. It includes the identification of the functions and requirements of the HC-HTGR RCCS, design analyses including high-level design consideration and the calculations for optimizing design space of the system with supporting component-level analysis to inform the material selection and performance of the water panel, the description of the conceptual design of the HC-HTGR RCCS derived based on the analyses results, and performance evaluation of the conceptual RCCS for the HC-HTGR. A detailed concept of the RCCS has been identified and high-level system requirements has been developed for the HC-HTGR. Design space focusing on the natural circulation loop portion of the RCCS has been investigated to optimize the system performance. The initial baseline dimensions were firstly derived based on the scoping calculations. A component level design analysis was conducted for the water panel to inform the material selection and to assess its conduction performance. A preliminary system-level performance analysis was performed for the 1/8th of the compartment of the initial baseline design of the RCCS using RELAP5-3D. To improve the system thermal performance, the RCCS design has been updated by exploring various design options by design parametric analyses. Based on the results, the conceptual design of the RCCS for the HC-HTGR has been derived, which satisfies the target performance of ~1 MWt at the elevated vessel wall temperature conditions. Transient simulations were conducted for the conceptual RCCS design for the HC-HTGR under various operation modes and heat load conditions using RELAP5-3D. The system dynamics in different operating states was investigated and the system performance under transients of interest was evaluated. The results demonstrated the overall system feasibility that the RCCS design maintains structures temperatures lower than maximum allowable temperature with sufficient system inventory without any active heat removal in the design process with certain transients addressed. The HC-HTGR RCCS will have additional design updates of subsystems or optimization of the system components during the preliminary and final design phases. Since the entire plant has not been integrated yet, this delivered conceptual design is subject to changes for integration, that require additional conceptual design activities and Quality and Assurance implementation (Q&A). The performance assessment of the RCCS for the HC-HTGR will be then revisited and optimized to finalize the system design, and the RCCS integrated primary system analysis will be utilized to simulate selective accident scenarios of interest where efforts are currently undergoing in the project.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period October 2022-March 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary heat transport system to ensure temperatures in the reactor systems, structures and components with significant safety margins during normal operation and design basis accident scenarios. This third semi-annual report summarized the progress made at Argonne on the two tasks during the first half of FY23. As a part of the RCCS design task, a design process for the water panel and the system configuration was performed to improve the thermal performance of the RCCS. The updated water panel design had achieved enhanced thermal performance with 0.96 MWth capability with major design updates made in structural interfaces with the RPV and initial configuration of the water tanks. The loop configuration of the RCCS has been proposed to have two independently working loops for system redundancy. A water panel material study was performed focusing on the use of carbon steel in water systems. Additional modeling strategies of primary system thermal fluids analyses were developed to meet modeling needs that are not well suited for the 1D-3D assembly level approach. The first of these is a reduced order assembly model, in which fuel centered unit cells are used to represent a fuel assembly. The 2D approach used in this model is much more computationally efficient, making this model useful for full core transient scenarios where fuel to coolant heat transfer is still the dominant flow path. The next model is the 3D core conduction model to be used to analyze decay heat removal in loss of primary system flow scenarios. Because these scenarios require a large domain to be modeled, a homogenized core model is being pursued to reduce the required computational costs. To accurately model decay heat scenarios it is necessary to couple a RCCS model to the 3D core conduction model. A simplified case is presented to demonstrate how the coupling methodology will be applied to the full core 3D conduction model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Semi-Annual Report for Modular Integrated Gas High Temperature Reactor Development during Performance Period April 2022 - September 2022

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multidisciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary coolant system to ensure temperatures within the core remain below safety margins during steady-state and potential accident scenarios. This second semi-annual report summarized the progress made at Argonne on the two tasks during the second half of FY22. As a part of the RCCS design task, a scoping calculation in estimating HVAC capability for the HC-HTGR reactor building was performed. A water panel modeling study was first performed with the test case, which confirms the capability of the RELAP5-3D modeling approach to explore various design options of the HC-HTGR RCCS under consideration. Then, a reference RELAP5-3D model for the unit geometry of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate the performances of a single-phase natural circulation and panel conduction in various operating conditions. For the primary coolant system analysis task, preliminary thermal hydraulic analysis of the HC-HTGR core design was performed with a high resolution 1D fluid-3D solid coupled model using the System Analysis Module (SAM) to assess the assembly coolant channel and bypass flow mass flow rate distribution. Some preliminary work on the development of a full core reduced order model was discussed following the assembly level model to predict the core wide coolant flow distribution and to model certain operational and accidental transients.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Metal fuel relocation experiments with pressure injection

A pool-type sodium-cooled fast reactor (SFR) using metal fuels has a number of inherent safety features that can support benign consequences for design basis accidents (DBAs). Even in postulated severe accident conditions, the core is designed to remain under sub-critical condition in a passive coolable geometry. In case of the postulated severe accidents in SFRs, fuel relocation in the core region along the coolant channel is an important negative reactivity feedback factor that lowers the reactor power level and consequently eliminates the possibility of recriticality. Therefore, understanding the relocation behavior of fuels and the coolability of the relocated fuels in the postulated severe accident is one of the most important factors in the safety assessment of SFRs. In the present study, the relocation behavior of the metal fuel in a pin bundle geometry was investigated by injecting the metal fuels into the coolant channels with pressure. The first metal fuel relocation with pressure injection (RPI-1) experiment showed that many of the metal fuels levitated to upper plenum. In case of RPI-2 experiment, the Real Time X-ray Video System (RTXVS) was constructed and used to obtain a real time X-ray video of the experiment. This real time X-ray video clearly showed the relocation behavior of the pressure injected metallic uranium in the sodium coolant channel. Through this video, it was confirmed that part of the fuel was dispersed downward and part of the fuel was dispersed upward, and the relocation behavior of the injected fuel proceeded simultaneously in the downward and upward directions. So, it can be concluded that in case of pressure injection of the metallic fuel, there is a possibility that the metallic fuel can be quickly removed from the core region, resulting in a negative reactivity feedback effect.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Semi-Annual Report for Modular Integrated Gas High Temperature Reactor Development during Performance Period October 2021 - March 2022

Modular Integrated Gas High Temperature Reactor (MIGHTR) is being designed by a multidisciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Work performed by Argonne also includes the thermal hydraulics analysis of the primary heat transport system including reactor pressure vessel (RPV) internals for normal operation, shutdown, and accident conditions. This first semi-annual report summarizes the progress made at Argonne on the two tasks since the start of the project. For the RCCS design task, high-level design work was performed including identification of design requirements for the conceptual MIGHTR RCCS and initial design calculations. The baseline dimensions of the MIGHTR RCCS were derived from scoping analysis results and preliminary steady state performance was estimated. At the initial stage of the primary system analysis task, the primary system thermal fluids model for the MIGHTR core was outlined to use a simplified two-dimensional model to predict the temperature distribution and coolant pressure losses in the fuel assembly blocks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗