Search NASA⌕ Search

Engineering topics

Liu, Jiangjin

Publications and source records attributed to Liu, Jiangjin.

(Invited) Continuum Mathematical Modeling of Water Electrolysis: A Tutorial

Widespread use of hydrogen energy is contingent on the development of reliable and economical sources of hydrogen. Electrolysis from renewably-derived low-carbon electricity is a potentially viable method of hydrogen generation. Prime among the electrolysis technologies are those utilizing ion-conducting polymers (ionomers) including proton-exchange-membrane water electrolyzer (PEMWE). However, these technologies need to exhibit increased efficiency, performance, and durability to become commercially viable. Like most electrochemical devices, PEMWEs involve multiple components (e.g., catalyst, ionomer, transport layers, membrane, plates) and multiple phases, with phenomena occurring across different time and length scales. Furthermore, it is difficult to experimentally probe many of the species and phenomena during operation. Thus, mathematical modeling at the continuum level has been an invaluable aid in exploring, understanding, and optimizing PEMWE cell and components. Furthermore, this is especially true in the highly coupled and complex physics and chemistries that occur with the membrane-electrode assembly (MEA). The physics in a typical volume-averaged non-isothermal model include multiphase transport in porous media, concentrated-solution theory, Ohm's Law, and Butler-Volmer kinetics, and ion, gas, and water transport in the ionomer.

Dizon, Arthur↗

Coupled continuum and network model framework to study catalyst layers of polymer electrolyte fuel cells

The nanostructured thin film (NSTF) catalyst layers which have demonstrated high power densities, mass activities, and exceptional metal and support stability can have limited operational robustness due to their thin thickness and the hydrophilicity of the metal-coated nano whiskers. The dispersed nanostructured thin film (dNSTF) catalyst layers have been developed by dispersing the NSTF Pt whiskers with ionomer and carbon support to increase the thickness and hydrophobicity. Continuum and network models (NM) are coupled through boundary conditions to study the polymer electrolyte fuel cell with a dNSTF cathode catalyst layer. The coupled model combines the computational efficiency of the continuum model with the pore-scale information in the dNSTF cathode catalyst layer of the NM. It captures the special morphology of the partially ionomer/water covered cylindrical whiskers, as well as water percolation through the pore structures and their impact on the cell performance. Here we observe optimal ionomer coverage on whiskers to be 0.5, ionomer to carbon ratio to be 0.9 and higher whisker to carbon ratios to be desired.

08 HYDROGEN↗

Linking Perfluorosulfonic Acid Ionomer Chemistry and High-Current Density Performance in Fuel-Cell Electrodes

Transport phenomena are key in controlling the performance of electrochemical energy-conversion technologies and can be highly complex, involving multiple length scales and materials/phases. Material designs optimized for one reactant species transport however may inhibit other transport processes. We explore such trade-offs in the context of polymer-electrolyte fuel-cell electrodes, where ionomer thin films provide the necessary proton conductivity but retard oxygen transport to the Pt reaction site and cause interfacial resistance due to sulfonate/Pt interactions. We examine the electrode overall gas-transport resistance and its components as a function of ionomer content and chemistry. Low-equivalent-weight ionomers allow better dissolved-gas and proton transport due to greater water uptake and low crystallinity but also cause significant interfacial resistance due to the high density of sulfonic acid groups. These effects of equivalent weight are also observed via in situ ionic conductivity and CO displacement measurements. Of critical importance, the results are supported by ex situ ellipsometry and X-ray scattering of model thin-film systems, thereby providing direct linkages and applicability of model studies to probe complex heterogeneous structures. Structural and resultant performance changes in the electrode are shown to occur above a threshold sulfonic-group loading, highlighting the significance of ink-based interactions. Furthermore, our findings and methodologies are applicable to a variety of solid-state energy-conversion devices and material designs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpreting Ionic Conductivity for Polymer Electrolyte Fuel Cell Catalyst Layers with Electrochemical Impedance Spectroscopy and Transmission Line Modeling

A cathode catalyst layer containing optimally distributed ionomer is critical to reduce the platinum loading and increase its utilization in polymer electrolyte fuel cells. Here, electrochemical impedance spectroscopy (EIS) was used to measure effective ionic conductivity of pseudo catalyst layers (PCLs) at a relative humidity (RH) range of 50%-120%. These results are compared to previous work using the hydrogen pump (HP) method. EIS effective ionic conductivity results reported here are higher than those from the HP because in the HP set-up ionic pathways must be effectively connected through the PCL to be counted, whereas in the EIS measurement, ionomer segments that are in contact with the membrane but are not effectively connected all the way through the PCL can be detected. Double layer capacitances and effective ionic conductivities of Pt/C catalyst layers with various supports and ionomer to carbon (I/C) ratios were studied. High surface area carbon support resulted in a lower effective ionic conductivity compared to the graphitized carbon support due to worse ionomer dispersion. Effective ionic conductivities of Pt/C layers were compared to that of PCLs. On average, effective ionic conductivities of Pt/C layers were higher than PCLs because of possible carbon agglomeratio n within the PCLs.

25 ENERGY STORAGE↗

Mathematical Modeling of Hydroxide-Exchange-Membrane Water Electrolyzer

Water electrolyzers can transform intermittent renewable energy like solar energy and wind energy into the chemical energy of hydrogen with zero greenhouse-gas emissions. The hydroxide-exchange membrane electrolyzer (HEME) combines the capability to produce pressurized hydrogen with the advantage of being able to use low or non-platinum group metal (PGM) electrocatalysts in the alkaline environment.1 Hydroxide salts, for example, KOH, are added to the HEME water feed on both anode and cathode to improve its performance. However, the specific mechanism of performance improvement still needs to be further understood. In addition, at high current densities, bubble evolution can result in mass-transport limitations, a less well studied phenomena. Mathematical modeling is ideal to explore these issues as it is cost and time efficient and can deconvolute the physics, processes, and observed phenomena and study the applied-voltage breakdown. In this work, we extend our previously developed 1D two-phase continuum model2 to study the varies processes in the HEME and provide insights on performance optimizations. First, the oxygen evolution reaction (OER) and hydrogen evolution reaction (HER) kinetics at different hydroxide concentrations have been studied by rotating disk electrodes (RDE) and implemented in the model. Then, the model is calibrated and validated against experimental HEME polarization curves for different KOH concentrations as a liquid electrolyte. The model clearly shows a performance increase with increasing KOH concentrations, which is consistent with the experimental results. The reduced ohmic resistance and increased electrochemical active surface area (ECSA) are the two main reasons for performance increase. The large amount of hydroxide in the liquid electrolyte not only helps to distribute the reactant hydroxide throughout the catalyst layer (CL), which reduces ohmic loss, but also enables reaction at the interface between the liquid electrolyte and electrocatalyst, which increases the ECSA. Applied-voltage breakdown demonstrates that the electrolyzer performance is dominated by anode kinetics and ohmic loss. A comparison with the DI water feed shows a more uniform current distribution in the anode CL when KOH is added, which indicates a higher utilization of the CL. Second, we present modeling on the effects of bubble coverage. As gas evolves, part of the ECSA is minimized due to bubble coverage. To account for this effect, an empirical relationship between the fractional bubble coverage and the current density is implemented in the model.3 The model shows this bubble coverage effect is more pronounced at large current densities with DI water feed. Acknowledgements This work was funded under the HydroGEN Consortium by the Energy Efficiency and Renewable Energy, Hydrogen and Fuel Cell Technologies Office, of the U. S. Department of Energy under contract number DE-AC02-05CH11231. References R. Abbasi, B. P. Setzler, S. Lin, J. Wang, Y. Zhao, H. Xu, B. Pivovar, B. Tian, X. Chen, G. Wu and Y. Yan, 31, 1805876 (2019). L. N. Stanislaw, M. R. Gerhardt and A. Z. Weber, ECS Transactions, 92, 767 (2019). H. Vogt and R. J. Balzer, Electrochimica Acta, 50, 2073 (2005).

Liu, Jiangjin↗

Hierarchical electrode design of highly efficient and stable unitized regenerative fuel cells (URFCs) for long-term energy storage

The unitized regenerative fuel cell (URFC) is a promising electrochemical device for intermittent renewable energy storage in chemical bonds. However, widespread application has been hindered due to low round-trip efficiencies (RTEs) and disappointing durability, in particular at high rates. In this study, we break through that barrier by demonstrating highly efficient, flexible, and stable URFCs via hierarchical design of the multiscale catalyst-layer structures. A more porous and less tortuous Pt and Ir catalyst layer is realized using a doctor blade fabrication method that significantly improves URFC performance. We demonstrate RTEs of 56% and 53% under constant-electrode and constant-gas mode, respectively, while operating at 1000 mA cm –2 , and significantly, a RTE of 45% at 2000 mA cm –2 , achievements that were previously viewed as unfeasible under the onerous demands of URFC operation. At the same time we demonstrate URFCs under both constant-electrode and constant-gas mode operated continuously for over 500 h with negligible degradation. These results demonstrate the viability of applying URFCs for long-term energy storage at previously unattainable efficiencies and cast new light on electrode design and optimization of URFCs.

25 ENERGY STORAGE↗