Search NASA⌕ Search

Engineering topics

Liu, T.

Publications and source records attributed to Liu, T..

At least 37 records · Page 2

The eROSITA Final Equatorial-Depth Survey (eFEDS)

In 2019, the eROSITA telescope on board the Russian-German satellite Spectrum-Roentgen-Gamma (SRG) began to perform a deep all-sky X-ray survey with the aim of identifying ~100 000 clusters and groups over the course of four years. As part of its performance verification phase, a ~140 deg 2 survey, called eROSITA Final Equatorial-Depth Survey (eFEDS), was performed. With a depth typical of the all-sky survey after four years, it allows tests of tools and methods as well as improved predictions for the all-sky survey. As part of this effort, a catalog of 542 X-ray selected galaxy group and cluster candidates was compiled. Here, in this paper, we present the optical follow-up, with the aim of providing redshifts and cluster confirmation for the full sample. Furthermore, we aim to provide additional information on the dynamical state, richness, and optical center of the clusters. Finally, we aim to evaluate the impact of optical cluster confirmation on the purity and completeness of the X-ray selected sample. We used optical imaging data from the Hyper Suprime-Cam Subaru Strategic Program and from the Legacy Survey to identify optical counterparts to the X-ray detected cluster candidates. We make use of the multi-component matched filter cluster confirmation tool (MCMF), as well as of the optical cluster finder CAMIRA to derive cluster redshifts and richnesses. MCMF provided the probabilities with which an optical structure would be a chance superposition with the X-ray candidate. These probabilities were used to identify the best optical counterpart as well as to confirm an X-ray candidate as a cluster. The impact of this confirmation process on catalog purity and completeness was estimated using optical to X-ray scaling relations as well as simulations. The resulting catalog was furthermore matched with public group and cluster catalogs. Optical estimators of the cluster dynamical state were constructed based on density maps of the red-sequence galaxies at the cluster redshift. By providing redshift estimates for all 542 candidates, we construct an optically confirmed sample of 477 clusters and groups with a residual contamination of 6%. Of these, 470 (98.5%) are confirmed using MCMF, and 7 systems are added through cross-matching with spectroscopic group catalogs. Using observable-to-observable scaling and the applied confirmation threshold, we predict that 8 ± 2 real systems have been excluded with the MCMF cut required to build this low-contamination sample. This number agrees well with the 7 systems found through cross-matching that were not confirmed with MCMF. The predicted redshift and mass distribution of this catalog agree well with simulations. Thus, we expect that these 477 systems include >99% of all true clusters in the candidate list. Using an MCMF-independent method, we confirm that the catalog contamination of the confirmed subsample is 6 ± 3%. Application of the same method to the full candidate list yields 17 ± 3%, consistent with estimates coming from the fraction of confirmed systems of ~17% and with expectations from simulations of ~20%. We also present a sample of merging cluster candidates based on the derived estimators of the cluster dynamical state.

79 ASTRONOMY AND ASTROPHYSICS↗

The eROSITA Final Equatorial-Depth Survey (eFEDS): Identification and characterization of the counterparts to point-like sources

In November 2019, eROSITA on board of the Spektrum-Roentgen-Gamma (SRG) observatory started to map the entire sky in X-rays. After the four-year survey program, it will reach a flux limit that is about 25 times deeper than ROSAT. During the SRG performance verification phase, eROSITA observed a contiguous 140 deg 2 area of the sky down to the final depth of the eROSITA all-sky survey (eROSITA Final Equatorial-Depth Survey; eFEDS), with the goal of obtaining a census of the X-ray emitting populations (stars, compact objects, galaxies, clusters of galaxies, and active galactic nuclei) that will be discovered over the entire sky. This paper presents the identification of the counterparts to the point sources detected in eFEDS in the main and hard samples and their multi-wavelength properties, including redshift. To identify the counterparts, we combined the results from two independent methods (NWAY and ASTROMATCH), trained on the multi-wavelength properties of a sample of 23k XMM-Newton sources detected in the DESI Legacy Imaging Survey DR8. Then spectroscopic redshifts and photometry from ancillary surveys were collated to compute photometric redshifts. Of the eFEDS sources, 24 774 of 27 369 have reliable counterparts (90.5%) in the main sample and 231 of 246 sources (93.9%) have counterparts in the hard sample, including 2514 (3) sources for which a second counterpart is equally likely. By means of reliable spectra, Gaia parallaxes, and/or multi-wavelength properties, we have classified the reliable counterparts in both samples into Galactic (2695) and extragalactic sources (22 079). For about 340 of the extragalactic sources, we cannot rule out the possibility that they are unresolved clusters or belong to clusters. Inspection of the distributions of the X-ray sources in various optical/IR colour-magnitude spaces reveal a rich variety of diverse classes of objects. The photometric redshifts are most reliable within the KiDS/VIKING area, where deep near-infrared data are also available. This paper accompanies the eROSITA early data release of all the observations performed during the performance and verification phase. Together with the catalogues of primary and secondary counterparts to the main and hard samples of the eFEDS survey, this paper releases their multi-wavelength properties and redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

The eROSITA Final Equatorial Depth Survey (eFEDS), completed in survey mode during the calibration and performance verification phase of the eROSITA instrument on Spectrum Roentgen Gamma, delivers data at and beyond the final depth of the 4-yr eROSITA all-sky survey (eRASS:8), f 0.5–2 keV = 1.1 × 10 –14 erg s –1 cm –2 , over 140 deg 2 . It provides the first view of normal galaxy X-ray emission from X-ray binaries (XRBs) and the hot interstellar medium at the full depth of eRASS:8. We used the Heraklion Extragalactic Catalogue (HECATE) of galaxies to correlate with eFEDS X-ray sources and identify X-ray detected normal galaxies. This flux-limited X-ray survey is relatively free from selection effects and enables the study of integrated normal galaxy X-ray emission and its relation to galaxy parameters such as the stellar mass, star formation rate (SFR), and metallicity. We cross-correlated 32 646 eFEDS X-ray sources to 1181 HECATE normal galaxies and obtained 94 matches. We classified galaxies as star-forming, early-type, composite, and active galactic nuclei (AGN) using Sloan Digital Sky Survey (SDSS) and Six-degree Field (6dF) optical spectroscopy. The eFEDS field harbours 37 normal galaxies: 36 late-type (star-forming) galaxies and one early-type galaxy. There are 1.9 times as many normal galaxies as predicted by scaling relations via simulations, with an overabundance of late-type galaxies and a dearth of early-type galaxies. When compared with empirical relations, eFEDS dwarf galaxies with a high specific SFR have elevated L X /SFR at a fixed specific SFR and metallicity, indicating an increase in XRB emission due to low metallicity. We expect that eRASS:8 will detect 12 500 normal galaxies, the majority of which will be star-forming, with the caveat that there are unclassified sources in eFEDS and galaxy catalogue incompleteness issues that could increase the actual number of detected galaxies over these current estimates. eFEDS observations detected a rare population of galaxies – the metal-poor dwarf starbursts – that do not follow known scaling relations. eRASS is expected to discover significant numbers of these high-redshift analogues, which are important for studying the heating of the intergalactic medium at high redshift. Further investigation of the hot gas emission from normal galaxies and stochastic effects in the dwarf galaxy population are required to constrain their X-ray output.

79 ASTRONOMY AND ASTROPHYSICS↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

Aims. The eROSITA Final Equatorial-Depth Survey (eFEDS), executed during the performance verification phase of the Spectrum-Roentgen-Gamma (SRG)/eROSITA telescope, was completed in November 2019. One of the science goals of this survey is to demonstrate the ability of eROSITA to detect samples of clusters and groups at the final depth of the eROSITA all-sky survey. Methods. Because of the sizeable (≈26" HEW FOV average) point-spread function of eROSITA, high-redshift clusters of galaxies or compact nearby groups hosting bright active galactic nuclei (AGN) can be misclassified as point sources by the source detection algorithms. A total of 346 galaxy clusters and groups in the redshift range of 0.1 < z < 1.3 were identified based on their red sequenc in the eFEDS point source catalog. Results. We examine the multiwavelength properties of these clusters and groups to understand the potential biases in our selection process and the completeness of the extent-selected sample. We find that the majority of the clusters and groups in the point source sample are indeed underluminous and compact compared to the extent-selected sample. Their faint X-ray emission, well below the flux limit of the extent-selected eFEDS clusters, and their compact X-ray emission are likely to be the main reason for this misclassification. In the sample, we confirm that 10% of the sources host AGN in their brightest cluster galaxies (BCGs) through optical spectroscopy and visual inspection. By studying their X-ray, optical, infrared, and radio properties, we establish a method for identifying clusters and groups that host AGN in their BCGs. We successfully test this method on the current point source catalog through the Sloan Digital Sky Survey optical spectroscopy and find eight low-mass clusters and groups with active radio-loud AGN that are particularly bright in the infrared. They include eFEDS J091437.8+024558, eFEDS J083520.1+012516, and eFEDS J092227.1+043339 at redshifts 0.3-0.4. Conclusions. This study helps us to characterize and understand our selection process and assess the completeness of the eROSITA extent-selected samples. The method we developed will be used to identify high-redshift clusters, AGN-dominated groups, and low-mass clusters that are misclassified in the future eROSITA all-sky survey point source catalogs.

79 ASTRONOMY AND ASTROPHYSICS↗

QTIA, a 2.5 or 10 Gbps 4-channel array optical receiver ASIC in a 65 nm CMOS technology

Here, the Quad transimpedance and limiting amplifier (QTIA) is a 4-channel array optical receiver ASIC, developed using a 65 nm CMOS process. It is configurable between the bit rate of 2.56 Gbps and 10 Gbps per channel. QTIA offers careful matching to both GaAs and InGaAs photodiodes. At this R&D stage, each channel has a different biasing scheme to the photodiode for optimal coupling. A charge pump is implemented in one channel to provide a higher reverse bias voltage, which is especially important to mitigate radiation effects on the photodiodes. The circuit functions of QTIA successfully passed the lab tests with GaAs photodiodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-phase Mn speciation in suspended particles along meltwater-influenced fjords of West Greenland

Manganese (Mn) is an essential micro-nutrient that can limit or, along with iron (Fe), co-limit phytoplankton growth in the ocean. Glacier meltwater is thought to be a key source of trace metals to high latitude coastal systems, but little is known about the nature of Mn delivered to glacially-influenced fjords and adjacent coastal waters. In this work, we combine in-situ dissolved Mn (dMn) measurements of surface waters with Mn K-edge X-ray absorption spectroscopy (XAS) data of suspended particles in four fjords of West Greenland. Data were collected from transects of up to 100 km in fjords with different underlying bedrock geology from 64 to 70°N. We found that dMn concentrations generally decreased conservatively with increasing salinity (from 80 to 120 nM at salinity < 8 to < 40 nM at salinities > 25). Dissolved Fe (dFe) trends in these fjords similarly declined with increasing distance from glacier outflows (declining from > 20 nM to < 8 nM). However, the dMn/dFe ratio increased rapidly likely due to the greater stability of dMn at intermediate salinities (i.e. 10–20) compared to rapid precipitation of dFe across the salinity gradient. The XAS data indicated a widespread presence of Mn(II)-rich suspended particles near fjord surfaces, with structures akin to Mn(II)-bearing phyllosilicates. However, a distinct increase in Mn oxidation state with depth and the predominance of birnessite-like Mn(IV) oxides was observed for suspended particles in a fjord with tertiary basalt geology. The similar dMn behaviour in fjords with different suspended particle Mn speciation (i.e., Mn(II)-bearing phyllosilicates and Mn(IV)-rich birnessite) is consistent with the decoupling of dissolved and particulate Mn and suggests that dMn concentrations on the scale of these fjords are controlled primarily by dilution of a freshwater dMn source rather than exchange between dissolved and particle phases. This work provides new insights into the Mn cycle in high latitude coastal waters, where small changes in the relative availabilities of dMn, dFe and macronutrients may affect the identity of the nutrient(s) proximally limiting primary production.

58 GEOSCIENCES↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A 40 Gbps Optical Transceiver for Particle Physics Experiments

We present the design and the test results of a quad-channel optical transceiver module (QTRx) possibly for future particle physics experiments. The transmitters of QTRx, each at 10 Gbps, are based on a Quad-channel VCSEL Diode array Driver (QLDD) and 1 x 4 VCSEL array. The receivers of QTRx, with data rates of 2.56 Gbps or 10 Gbps per channel, are based on a Quad-channel Trans-Impedance and limiting Amplifier (QTIA) and 1 x 4 photodiode array of GaAs or InGaAs. QTRx is 20 mm x 10 mm x 5 mm and couples to an MT fiber connector. Test results indicate that QTRx achieves the design goals with a power consumption of 124 mW per transmitter channel at 10 Gbps and 120 mW at 2.56 Gbps for the receiver channel with an on-chip charge pump. The sensitivities of QTIA are -17 dBm at 2.56 Gbps and -8 dBm at 10 Gbps, respectively. Further improvements with a gold-finger interface and a more compact optical lens are being designed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Decoupling of particles and dissolved iron downstream of Greenlandic glacier outflows

Glaciers can be a significant and locally dominant source of iron (Fe), a biologically essential micronutrient, in high latitude coastal seas. The vast majority of this glacial Fe delivery is associated with particles, yet the speciation of the solid-phase Fe and specifically the relationships that govern exchange between particulate and dissolved Fe phases in these environments are poorly described. Here, in this work, we performed measurements of in situ dissolved Fe (dFe) along meltwater and particle plumes in three transects around Disko Bay and Ameralik Fjord (West Greenland). Measurements of dFe were combined with Fe K-edge X-ray absorption spectroscopy analysis of ~40 suspended sediment samples obtained from the same transects and from select depth profiles down to 300 m. We observed relatively constant dFe levels (4 to 10 nM for nearly all dFe measurements) across fjords with widely varying particulate Fe(II) contents (from 20 to 90% Fe(II)), indicating that dFe concentrations had little dependence on the oxidation state of Fe in the suspended sediment. Particulate Fe data were grouped by underlying bedrock geology, with suspended sediment consisting of 80-90% biotite-like Fe(II) in fjords with Precambrian shield geology and poorly-ordered Fe(III) particles (<20-30% Fe(II)) in one fjord with suspended sediments derived from tertiary basalts. Our characterization data indicated no significant change in the average Fe oxidation state and bonding environment of particles along the fjord transects, implying that Fe(II) in biotite-like coordination is not a readily labile Fe form on this spatial scale. Finally, our results suggest that dFe in these glacially-modified coastal waters is buffered at a relatively constant low nM concentration due to factors other than particle Fe mineralogy and that glacier-derived Fe phases are relatively inert on this spatial scale.

54 ENVIRONMENTAL SCIENCES↗

In-pixel automatic threshold calibration for the CMS Endcap Timing Layer readout chip

We present the implementation and verification of an in-pixel automatic threshold calibration circuit for the CMS Endcap Timing Layer (ETL) in the High-Luminosity LHC upgrade. The discriminator threshold of the ETL readout chip (ETROC) needs to be calibrated regularly to mitigate the circuit baseline change. Traditional methods need a lot of communication through a slow control system hence are time-consuming. This paper describes an in-pixel automatic scheme with improvements in operating time and usability. In this scheme, a sample-accumulation circuit is used to measure the average discriminator output. A binary successive approximation and linear combination scan are applied to find the equivalent baseline. The actual calibration procedure has been first implemented in FPGA firmware and tested with the ETROC front-end prototype chip (ETROC0). The calibration circuit has been implemented with Triple Modular Redundancy (TMR) and verified with Single Event Effects (SEEs) simulation. A complete calibration process lasts 35 ms with a 40 MHz clock. In the worst case, the dynamic and static power consumption are estimated to be 300 uW and 10.4 uW, respectively. The circuit design, implemented in a 65 CMOS technology, will be integrated into ETROC2, the next iteration of the ETROC with a 16 x16 pixel matrix.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Test beam characterization of sensor prototypes for the CMS Barrel MIP Timing Detector

The MIP Timing Detector will provide additional timing capabilities for detection of minimum ionizing particles (MIPs) at CMS during the High Luminosity LHC era, improving event reconstruction and pileup rejection. The central portion of the detector, the Barrel Timing Layer (BTL), will be instrumented with LYSO:Ce crystals and Silicon Photomultipliers (SiPMs) providing a time resolution of about 30 ps at the beginning of operation, and degrading to 50-60 ps at the end of the detector lifetime as a result of radiation damage. In this work, we present the results obtained using a 120 GeV proton beam at the Fermilab Test Beam Facility to measure the time resolution of unirradiated sensors. A proof-of-concept of the sensor layout proposed for the barrel region of the MTD, consisting of elongated crystal bars with dimensions of about 3×3×57 mm3 and with double-ended SiPM readout, is demonstrated. This design provides a robust time measurement independent of the impact point of the MIP along the crystal bar. We tested LYSO:Ce bars of different thickness (2, 3, 4 mm) with a geometry close to the reference design and coupled to SiPMs manufactured by Hamamatsu and Fondazione Bruno Kessler. The various aspects influencing the timing performance such as the crystal thickness, properties of the SiPMs (e.g. photon detection efficiency), and impact angle of the MIP are studied. A time resolution of about 28 ps is measured for MIPs crossing a 3 mm thick crystal bar, corresponding to a most probable value (MPV) of energy deposition of 2.6 MeV, and of 22 ps for the 4.2 MeV MPV energy deposition expected in the BTL, matching the detector performance target for unirradiated devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal tomography 3D imaging of additively manufactured metallic structures

Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with the laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer and through reconstruction of data obtained from experimental measurements. Thermal tomography reconstructions of structure shape and dimensions are shown for the Inconel 718 AM structure which has variations in the horizontal plane but is uniform along the depth dimension. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and the Inconel 718 plate is produced with the LPBF method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBHs have the same sizes as the imprinted defects in the LPBF specimens but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects and allow for estimation of their sizes and locations. Results of this study demonstrate that thermal tomography can be used for visualization and quality control in AM.

36 MATERIALS SCIENCE↗