Search NASA⌕ Search

Engineering topics

Liu, T

Publications and source records attributed to Liu, T.

At least 37 records · Page 2

WE-AB-204-11: Development of a Nuclear Medicine Dosimetry Module for the GPU-Based Monte Carlo Code ARCHER

Purpose: To develop a nuclear medicine dosimetry module for the GPU-based Monte Carlo code ARCHER. Methods: We have developed a nuclear medicine dosimetry module for the fast Monte Carlo code ARCHER. The coupled electron-photon Monte Carlo transport kernel included in ARCHER is built upon the Dose Planning Method code (DPM). The developed module manages the radioactive decay simulation by consecutively tracking several types of radiation on a per disintegration basis using the statistical sampling method. Optimization techniques such as persistent threads and prefetching are studied and implemented. The developed module is verified against the VIDA code, which is based on Geant4 toolkit and has previously been verified against OLINDA/EXM. A voxelized geometry is used in the preliminary test: a sphere made of ICRP soft tissue is surrounded by a box filled with water. Uniform activity distribution of I-131 is assumed in the sphere. Results: The self-absorption dose factors (mGy/MBqs) of the sphere with varying diameters are calculated by ARCHER and VIDA respectively. ARCHER’s result is in agreement with VIDA’s that are obtained from a previous publication. VIDA takes hours of CPU time to finish the computation, while it takes ARCHER 4.31 seconds for the 12.4-cm uniform activity sphere case. For a fairer CPU-GPU comparison, more effort will be made to eliminate the algorithmic differences. Conclusion: The coupled electron-photon Monte Carlo code ARCHER has been extended to radioactive decay simulation for nuclear medicine dosimetry. The developed code exhibits good performance in our preliminary test. The GPU-based Monte Carlo code is developed with grant support from the National Institute of Biomedical Imaging and Bioengineering through an R01 grant (R01EB015478)

60 APPLIED LIFE SCIENCES↗

WE-EF-210-06: Ultrasound 2D Strain Measurement of Radiation-Induced Toxicity: Phantom and Ex Vivo Experiments

Purpose: Radiation-induced fibrosis is a common long-term complication affecting many patients following cancer radiotherapy. Standard clinical assessment of subcutaneous fibrosis is subjective and often limited to visual inspection and palpation. Ultrasound strain imaging describes the compressibility (elasticity) of biological tissues. This study’s purpose is to develop a quantitative ultrasound strain imaging that can consistently and accurately characterize radiation-induce fibrosis. Methods: In this study, we propose a 2D strain imaging method based on deformable image registration. A combined affine and B-spline transformation model is used to calculate the displacement of tissue between pre-stress and post-stress B-mode image sequences. The 2D displacement is estimated through a hybrid image similarity measure metric, which is a combination of the normalized mutual information (NMI) and normalized sum-of-squared-differences (NSSD). And 2D strain is obtained from the gradient of the local displacement. We conducted phantom experiments under various compressions and compared the performance of our proposed method with the standard cross-correlation (CC)- based method using the signal-to-noise (SNR) and contrast-to-noise (CNS) ratios. In addition, we conducted ex-vivo beef muscle experiment to further validate the proposed method. Results: For phantom study, the SNR and CNS values of the proposed method were significantly higher than those calculated from the CC-based method under different strains. The SNR and CNR increased by a factor of 1.9 and 2.7 comparing to the CC-based method. For the ex-vivo experiment, the CC-based method failed to work due to large deformation (6.7%), while our proposed method could accurately detect the stiffness change. Conclusion: We have developed a 2D strain imaging technique based on the deformable image registration, validated its accuracy and feasibility with phantom and ex-vivo data. This 2D ultrasound strain imaging technology may be valuable as physicians try to eliminate radiation-induce fibrosis and improve the therapeutic ratio of cancer radiotherapy. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.

60 APPLIED LIFE SCIENCES↗

WE-EF-210-08: BEST IN PHYSICS (IMAGING): 3D Prostate Segmentation in Ultrasound Images Using Patch-Based Anatomical Feature

Purpose: Transrectal ultrasound (TRUS) is the standard imaging modality for the image-guided prostate-cancer interventions (e.g., biopsy and brachytherapy) due to its versatility and real-time capability. Accurate segmentation of the prostate plays a key role in biopsy needle placement, treatment planning, and motion monitoring. As ultrasound images have a relatively low signal-to-noise ratio (SNR), automatic segmentation of the prostate is difficult. However, manual segmentation during biopsy or radiation therapy can be time consuming. We are developing an automated method to address this technical challenge. Methods: The proposed segmentation method consists of two major stages: the training stage and the segmentation stage. During the training stage, patch-based anatomical features are extracted from the registered training images with patient-specific information, because these training images have been mapped to the new patient’ images, and the more informative anatomical features are selected to train the kernel support vector machine (KSVM). During the segmentation stage, the selected anatomical features are extracted from newly acquired image as the input of the well-trained KSVM and the output of this trained KSVM is the segmented prostate of this patient. Results: This segmentation technique was validated with a clinical study of 10 patients. The accuracy of our approach was assessed using the manual segmentation. The mean volume Dice Overlap Coefficient was 89.7±2.3%, and the average surface distance was 1.52 ± 0.57 mm between our and manual segmentation, which indicate that the automatic segmentation method works well and could be used for 3D ultrasound-guided prostate intervention. Conclusion: We have developed a new prostate segmentation approach based on the optimal feature learning framework, demonstrated its clinical feasibility, and validated its accuracy with manual segmentation (gold standard). This segmentation technique could be a useful tool for image-guided interventions in prostate-cancer diagnosis and treatment. This research is supported in part by DOD PCRP Award W81XWH-13-1-0269, and National Cancer Institute (NCI) Grant CA114313.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-02: Application of ARCHERRT-- A GPU-Based Monte Carlo Dose Engine for Radiation Therapy -- to Tomotherapy and Patient-Independent IMRT

Purpose: As a module of ARCHER -- Accelerated Radiation-transport Computations in Heterogeneous EnviRonments, ARCHER{sub RT} is designed for RadioTherapy (RT) dose calculation. This paper describes the application of ARCHERRT on patient-dependent TomoTherapy and patient-independent IMRT. It also conducts a 'fair' comparison of different GPUs and multicore CPU. Methods: The source input used for patient-dependent TomoTherapy is phase space file (PSF) generated from optimized plan. For patient-independent IMRT, the open filed PSF is used for different cases. The intensity modulation is simulated by fluence map. The GEANT4 code is used as benchmark. DVH and gamma index test are employed to evaluate the accuracy of ARCHER{sub RT} code. Some previous studies reported misleading speedups by comparing GPU code with serial CPU code. To perform a fairer comparison, we write multi-thread code with OpenMP to fully exploit computing potential of CPU. The hardware involved in this study are a 6-core Intel E5-2620 CPU and 6 NVIDIA M2090 GPUs, a K20 GPU and a K40 GPU. Results: Dosimetric results from ARCHER{sub RT} and GEANT4 show good agreement. The 2%/2mm gamma test pass rates for different clinical cases are 97.2% to 99.7%. A single M2090 GPU needs 50~79 seconds for the simulation to achieve a statistical error of 1% in the PTV. The K40 card is about 1.7∼1.8 times faster than M2090 card. Using 6 M2090 card, the simulation can be finished in about 10 seconds. For comparison, Intel E5-2620 needs 507∼879 seconds for the same simulation. Conclusion: We successfully applied ARCHER{sub RT} to Tomotherapy and patient-independent IMRT, and conducted a fair comparison between GPU and CPU performance. The ARCHER{sub RT} code is both accurate and efficient and may be used towards clinical applications.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-03: Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT

Purpose: To compare the CT doses derived from the experiments and GPU-based Monte Carlo (MC) simulations, using a human cadaver and ATOM phantom. Methods: The cadaver of an 88-year old male and the ATOM phantom were scanned by a GE LightSpeed Pro 16 MDCT. For the cadaver study, the Thimble chambers (Model 10×5−0.6CT and 10×6−0.6CT) were used to measure the absorbed dose in different deep and superficial organs. Whole-body scans were first performed to construct a complete image database for MC simulations. Abdomen/pelvis helical scans were then conducted using 120/100 kVps, 300 mAs and a pitch factor of 1.375:1. For the ATOM phantom study, the OSL dosimeters were used and helical scans were performed using 120 kVp and x, y, z tube current modulation (TCM). For the MC simulations, sufficient particles were run in both cases such that the statistical errors of the results by ARCHER-CT were limited to 1%. Results: For the human cadaver scan, the doses to the stomach, liver, colon, left kidney, pancreas and urinary bladder were compared. The difference between experiments and simulations was within 19% for the 120 kVp and 25% for the 100 kVp. For the ATOM phantom scan, the doses to the lung, thyroid, esophagus, heart, stomach, liver, spleen, kidneys and thymus were compared. The difference was 39.2% for the esophagus, and within 16% for all other organs. Conclusion: In this study the experimental and simulated CT doses were compared. Their difference is primarily attributed to the systematic errors of the MC simulations, including the accuracy of the bowtie filter modeling, and the algorithm to generate voxelized phantom from DICOM images. The experimental error is considered small and may arise from the dosimeters. R01 grant (R01EB015478) from National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

TU-A-9A-06: Semi-Automatic Segmentation of Skin Cancer in High-Frequency Ultrasound Images: Initial Comparison with Histology

Purpose: In skin-cancer radiotherapy, the assessment of skin lesion is challenging, particularly with important features such as the depth and width hard to determine. The aim of this study is to develop interative segmentation method to delineate tumor boundary using high-frequency ultrasound images and to correlate the segmentation results with the histopathological tumor dimensions. Methods: We analyzed 6 patients who comprised a total of 10 skin lesions involving the face, scalp, and hand. The patient’s various skin lesions were scanned using a high-frequency ultrasound system (Episcan, LONGPORT, INC., PA, U.S.A), with a 30-MHz single-element transducer. The lateral resolution was 14.6 micron and the axial resolution was 3.85 micron for the ultrasound image. Semiautomatic image segmentation was performed to extract the cancer region, using a robust statistics driven active contour algorithm. The corresponding histology images were also obtained after tumor resection and served as the reference standards in this study. Results: Eight out of the 10 lesions are successfully segmented. The ultrasound tumor delineation correlates well with the histology assessment, in all the measurements such as depth, size, and shape. The depths measured by the ultrasound have an average of 9.3% difference comparing with that in the histology images. The remaining 2 cases suffered from the situation of mismatching between pathology and ultrasound images. Conclusion: High-frequency ultrasound is a noninvasive, accurate and easy-accessible modality to image skin cancer. Our segmentation method, combined with high-frequency ultrasound technology, provides a promising tool to estimate the extent of the tumor to guide the radiotherapy procedure and monitor treatment response.

60 APPLIED LIFE SCIENCES↗

TU-F-BRF-02: MR-US Prostate Registration Using Patient-Specific Tissue Elasticity Property Prior for MR-Targeted, TRUS-Guided HDR Brachytherapy

Purpose: High-dose-rate (HDR) brachytherapy has become a popular treatment modality for prostate cancer. Conventional transrectal ultrasound (TRUS)-guided prostate HDR brachytherapy could benefit significantly from MR-targeted, TRUS-guided procedure where the tumor locations, acquired from the multiparametric MRI, are incorporated into the treatment planning. In order to enable this integration, we have developed a MR-TRUS registration with a patient-specific biomechanical elasticity prior. Methods: The proposed method used a biomechanical elasticity prior to guide the prostate volumetric B-spline deformation in the MRI and TRUS registration. The patient-specific biomechanical elasticity prior was generated using ultrasound elastography, where two 3D TRUS prostate images were acquired under different probe-induced pressures during the HDR procedure, which takes 2-4 minutes. These two 3D TRUS images were used to calculate the local displacement (elasticity map) of two prostate volumes. The B-spline transformation was calculated by minimizing the Euclidean distance between the normalized attribute vectors of the prostate surface landmarks on the MR and TRUS. This technique was evaluated through two studies: a prostate-phantom study and a pilot study with 5 patients undergoing prostate HDR treatment. The accuracy of our approach was assessed through the locations of several landmarks in the post-registration and TRUS images; our registration results were compared with the surface-based method. Results: For the phantom study, the mean landmark displacement of the proposed method was 1.29±0.11 mm. For the 5 patients, the mean landmark displacement of the surface-based method was 3.25±0.51 mm; our method, 1.71±0.25 mm. Therefore, our proposed method of prostate registration outperformed the surfaced-based registration significantly. Conclusion: We have developed a novel MR-TRUS prostate registration approach based on patient-specific biomechanical elasticity prior. Successful integration of multi-parametric MR and TRUS prostate images provides a prostate-cancer map for treatment planning, enables accurate dose planning and delivery, and potentially enhances prostate HDR treatment outcome.

60 APPLIED LIFE SCIENCES↗

TU-F-12A-09: GLCM Texture Analysis for Normal-Tissue Toxicity: A Prospective Ultrasound Study of Acute Toxicity in Breast-Cancer Radiotherapy

Purpose: To evaluate the morphologic and structural integrity of the breast glands using sonographic textural analysis, and identify potential early imaging signatures for radiation toxicity following breast-cancer radiotherapy (RT). Methods: Thirty-eight patients receiving breast RT participated in a prospective ultrasound imaging study. Each participant received 3 ultrasound scans: 1 week before RT (baseline), and at 6-week and 3-month follow-ups. Patients were imaged with a 10-MHz ultrasound on the four quadrant of the breast. A second order statistical method of texture analysis, called gray level co-occurrence matrix (GLCM), was employed to assess RT-induced breast-tissue toxicity. The region of interest (ROI) was 28 mm × 10 mm in size at a 10 mm depth under the skin. Twenty GLCM sonographic features, ratios of the irradiated breast and the contralateral breast, were used to quantify breast-tissue toxicity. Clinical assessment of acute toxicity was conducted using the RTOG toxicity scheme. Results: Ninety-seven ultrasound studies (776 images) were analyzed; and 5 out of 20 sonographic features showed significant differences (p < 0.05) among the baseline scans, the acute toxicity grade 1 and 2 groups. These sonographic features quantified the degree of tissue damage through homogeneity, heterogeneity, randomness, and symmetry. Energy ratio value decreased from 108±0.05 (normal) to 0.99±0.05 (Grade 1) and 0.84±0.04 (Grade 2); Entropy ratio value increased from 1.01±0.01 to 1.02±0.01 and 1.04±0.01; Contrast ratio value increased from 1.03±0.03 to 1.07±0.06 and 1.21±0.09; Variance ratio value increased from 1.06±0.03 to 1.20±0.04 and 1.42±0.10; Cluster Prominence ratio value increased from 0.98±0.02 to 1.01±0.04 and 1.25±0.07. Conclusion: This work has demonstrated that the sonographic features may serve as imaging signatures to assess radiation-induced normal tissue damage. While these findings need to be validated in a larger cohort, they suggest that ultrasound imaging may be used to improve early detection of normal-tissue toxicity in breast-cancer RT.

60 APPLIED LIFE SCIENCES↗

TH-E-BRF-09: Gaussian Mixture Model Analysis of Radiation-Induced Parotid-Gland Injury: An Ultrasound Study of Acute and Late Xerostomia in Head-And-Neck Radiotherapy

Purpose: Xerostomia (dry mouth), secondary to parotid-gland injury, is a distressing side-effect in head-and-neck radiotherapy (RT). This study's purpose is to develop a novel ultrasound technique to quantitatively evaluate post-RT parotid-gland injury. Methods: Recent ultrasound studies have shown that healthy parotid glands exhibit homogeneous echotexture, whereas post-RT parotid glands are often heterogeneous, with multiple hypoechoic (inflammation) or hyperechoic (fibrosis) regions. We propose to use a Gaussian mixture model to analyze the ultrasonic echo-histogram of the parotid glands. An IRB-approved clinical study was conducted: (1) control-group: 13 healthy-volunteers, served as the control; (2) acutetoxicity group − 20 patients (mean age: 62.5 ± 8.9 years, follow-up: 2.0±0.8 months); and (3) late-toxicity group − 18 patients (mean age: 60.7 ± 7.3 years, follow-up: 20.1±10.4 months). All patients experienced RTOG grade 1 or 2 salivary-gland toxicity. Each participant underwent an ultrasound scan (10 MHz) of the bilateral parotid glands. An echo-intensity histogram was derived for each parotid and a Gaussian mixture model was used to fit the histogram using expectation maximization (EM) algorithm. The quality of the fitting was evaluated with the R-squared value. Results: (1) Controlgroup: all parotid glands fitted well with one Gaussian component, with a mean intensity of 79.8±4.9 (R-squared>0.96). (2) Acute-toxicity group: 37 of the 40 post-RT parotid glands fitted well with two Gaussian components, with a mean intensity of 42.9±7.4, 73.3±12.2 (R-squared>0.95). (3) Latetoxicity group: 32 of the 36 post-RT parotid fitted well with 3 Gaussian components, with mean intensities of 49.7±7.6, 77.2±8.7, and 118.6±11.8 (R-squared>0.98). Conclusion: RT-associated parotid-gland injury is common in head-and-neck RT, but challenging to assess. This work has demonstrated that the Gaussian mixture model of the echo-histogram could quantify acute and late toxicity of the parotid glands. This study provides meaningful preliminary data from future observational and interventional clinical research.

60 APPLIED LIFE SCIENCES↗

SU-D-9A-06: 3D Localization of Neurovascular Bundles Through MR-TRUS Registration in Prostate Radiotherapy

Purpose: Erectile dysfunction (ED) is the most common complication of prostate-cancer radiotherapy (RT) and the major mechanism is radiation-induced neurovascular bundle (NVB) damage. However, the localization of the NVB remains challenging. This study's purpose is to accurately localize 3D NVB by integrating MR and transrectal ultrasound (TRUS) images through MR-TRUS fusion. Methods: T1 and T2-weighted MR prostate images were acquired using a Philips 1.5T MR scanner and a pelvic phase-array coil. The 3D TRUS images were captured with a clinical scanner and a 7.5 MHz biplane probe. The TRUS probe was attached to a stepper; the B-mode images were captured from the prostate base to apex at a 1-mm step and the Doppler images were acquired in a 5-mm step. The registration method modeled the prostate tissue as an elastic material, and jointly estimated the boundary condition (surface deformation) and the volumetric deformations under elastic constraint. This technique was validated with a clinical study of 7 patients undergoing RT treatment for prostate cancer. The accuracy of our approach was assessed through the locations of landmarks, as well as previous ultrasound Doppler images of patients. Results: MR-TRUS registration was successfully performed for all patients. The mean displacement of the landmarks between the post-registration MR and TRUS images was 1.37±0.42 mm, which demonstrated the precision of the registration based on the biomechanical model; and the NVB volume Dice Overlap Coefficient was 92.1±3.2%, which demonstrated the accuracy of the NVB localization. Conclusion: We have developed a novel approach to improve 3D NVB localization through MR-TRUS fusion for prostate RT, demonstrated its clinical feasibility, and validated its accuracy with ultrasound Doppler data. This technique could be a useful tool as we try to spare the NVB in prostate RT, monitor NBV response to RT, and potentially improve post-RT potency outcomes.

60 APPLIED LIFE SCIENCES↗

SU-E-T-352: Why Is the Survival Rate Low in Oropharyngeal Squamous Cell Carcinoma?

Purpose: Tumors are composed of a large number of clonogens that have the capability of indefinite reproduction. Even when there is complete clinical or radiographic regression of the gross tumor mass after treatment, tumor recurrence can occur if the clonogens are not completely eradicated by radiotherapy. This study was to investigate the colonogen number and its association with the tumor control probability (TCP) in oropharyngeal squamous cell carcinoma (OSCCA). Methods: A literature search was conducted to collect clinical information of patients with OSCCA, including the prescription dose, tumor volume and survival rate. The linear-quadratic (LQ) model was incorporated into TCP model for clinical data analysis. The total dose ranged from 60 to 70 Gy and tumor volume ranged from 10 to 50 cc. The TCP was calculated for each group according to tumor size and dose. The least χ{sup 2} method was used to fit the TCP calculation to clinical data while other LQ model parameters (α, β) were adopted from the literature, due to the limited patient data. Results: A total of 190 patients with T2–T4 OSCCA were included. The association with HPV was not available for all the patients. The 3-year survival rate was about 82% for T2 squamous cell carcinoma and 40% for advanced tumors. Fitting the TCP model to the survival data, the average clonogen number was 1.56×10{sup 12}. For the prescription dose of 70 Gy, the calculated TCP ranged from 40% to 90% when the tumor volume varied from 10 to 50 cc. Conclusion: Our data suggests variation between the clonogen number and TCP in OSCCA. Tumors with larger colonogen number tend to have lower TCP and therefore dose escalation above 70 Gy may be indicated in order to improve the TCP and survival rate. Our result will require future confirmation with a large number of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-618: Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT for Cervical Cancer

Purpose: To evaluate the dosimetric characteristics of intensity-modulated radiotherapy (IMRT) treatment plan with beam angle optimization. Methods: Ten post-operation patients with cervical cancer were included in this analysis. Two IMRT plans using seven beams were designed in each patient. A standard coplanar equi-space beam angles were used in the first plan (plan 1), whereas the selection of beam angle was optimized by beam angle optimization algorithm in Varian Eclipse treatment planning system for the same number of beams in the second plan (plan 2). Two plans were designed for each patient with the same dose-volume constraints and prescription dose. All plans were normalized to the mean dose to PTV. The dose distribution in the target, the dose to the organs at risk and total MU were compared. Results: For conformity and homogeneity in PTV, no statistically differences were observed in the two plans. For the mean dose in bladder, plan 2 were significantly lower than plan 1(p<0.05). No statistically significant differences were observed between two plans for the mean doses in rectum, left and right femur heads. Compared with plan1, the average monitor units reduced 16% in plan 2. Conclusion: The IMRT plan based on beam angle optimization for cervical cancer could reduce the dose delivered to bladder and also reduce MU. Therefore there were some dosimetric advantages in the IMRT plan with beam angle optimization for cervical cancer.

60 APPLIED LIFE SCIENCES↗

Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8: Instrumentation Frontier

These reports present the results of the 2013 Community Summer Study of the APS Division of Particles and Fields ("Snowmass 2013") on the future program of particle physics in the U.S. Chapter 8, on the Instrumentation Frontier, discusses the instrumentation needs of future experiments in the Energy, Intensity, and Cosmic Frontiers, promising new technologies for particle physics research, and issues of gathering resources for long-term research in this area.

47 OTHER INSTRUMENTATION↗

THE CHANDRA DEEP FIELD-SOUTH SURVEY: 4 Ms SOURCE CATALOGS

We present source catalogs for the 4 Ms Chandra Deep Field-South (CDF-S), which is the deepest Chandra survey to date and covers an area of 464.5 arcmin{sup 2}. We provide a main Chandra source catalog, which contains 740 X-ray sources that are detected with WAVDETECT at a false-positive probability threshold of 10{sup -5} in at least one of three X-ray bands (0.5-8 keV, full band; 0.5-2 keV, soft band; and 2-8 keV, hard band) and also satisfy a binomial-probability source-selection criterion of P < 0.004 (i.e., the probability of sources not being real is less than 0.004); this approach is designed to maximize the number of reliable sources detected. A total of 300 main-catalog sources are new compared to the previous 2 Ms CDF-S main-catalog sources. We determine X-ray source positions using centroid and matched-filter techniques and obtain a median positional uncertainty of {approx}0.''42. We also provide a supplementary catalog, which consists of 36 sources that are detected with WAVDETECT at a false-positive probability threshold of 10{sup -5}, satisfy the condition of 0.004 < P < 0.1, and have an optical counterpart with R < 24. Multiwavelength identifications, basic optical/infrared/radio photometry, and spectroscopic/photometric redshifts are provided for the X-ray sources in the main and supplementary catalogs. Seven hundred sixteen ({approx}97%) of the 740 main-catalog sources have multiwavelength counterparts, with 673 ({approx}94% of 716) having either spectroscopic or photometric redshifts. The 740 main-catalog sources span broad ranges of full-band flux and 0.5-8 keV luminosity; the 300 new main-catalog sources span similar ranges although they tend to be systematically lower. Basic analyses of the X-ray and multiwavelength properties of the sources indicate that >75% of the main-catalog sources are active galactic nuclei (AGNs); of the 300 new main-catalog sources, about 35% are likely normal and starburst galaxies, reflecting the rise of normal and starburst galaxies at the very faint flux levels uniquely accessible to the 4 Ms CDF-S. Near the center of the 4 Ms CDF-S (i.e., within an off-axis angle of 3'), the observed AGN and galaxy source densities have reached 9800{sup +1300}{sub -1100} deg{sup -2} and 6900{sup +1100}{sub -900} deg{sup -2}, respectively. Simulations show that our main catalog is highly reliable and is reasonably complete. The mean backgrounds (corrected for vignetting and exposure-time variations) are 0.063 and 0.178 counts Ms{sup -1} pixel{sup -1} (for a pixel size of 0.''492) for the soft and hard bands, respectively; the majority of the pixels have zero background counts. The 4 Ms CDF-S reaches on-axis flux limits of {approx}3.2 x 10{sup -17}, 9.1 x 10{sup -18}, and 5.5 x 10{sup -17} erg cm{sup -2} s{sup -1} for the full, soft, and hard bands, respectively. An increase in the CDF-S exposure time by a factor of {approx}2-2.5 would provide further significant gains and probe key unexplored discovery space.

79 ASTRONOMY AND ASTROPHYSICS↗

A new variable-resolution associative memory for high energy physics

We describe an important advancement for the Associative Memory device (AM). The AM is a VLSI processor for pattern recognition based on Content Addressable Memory (CAM) architecture. The AM is optimized for on-line track finding in high-energy physics experiments. Pattern matching is carried out by finding track candidates in coarse resolution 'roads'. A large AM bank stores all trajectories of interest, called 'patterns', for a given detector resolution. The AM extracts roads compatible with a given event during detector read-out. Two important variables characterize the quality of the AM bank: its 'coverage' and the level of fake roads. The coverage, which describes the geometric efficiency of a bank, is defined as the fraction of tracks that match at least one pattern in the bank. Given a certain road size, the coverage of the bank can be increased just adding patterns to the bank, while the number of fakes unfortunately is roughly proportional to the number of patterns in the bank. Moreover, as the luminosity increases, the fake rate increases rapidly because of the increased silicon occupancy. To counter that, we must reduce the width of our roads. If we decrease the road width using the current technology, the system will become very large and extremely expensive. We propose an elegant solution to this problem: the 'variable resolution patterns'. Each pattern and each detector layer within a pattern will be able to use the optimal width, but we will use a 'don't care' feature (inspired from ternary CAMs) to increase the width when that is more appropriate. In other words we can use patterns of variable shape. As a result we reduce the number of fake roads, while keeping the efficiency high and avoiding excessive bank size due to the reduced width. We describe the idea, the implementation in the new AM design and the implementation of the algorithm in the simulation. Finally we show the effectiveness of the 'variable resolution patterns' idea using simulated high occupancy events in the ATLAS detector. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance study of GPUs in real-time trigger applications for HEP experiments

Graphical Processing Units (GPUs) have evolved into highly parallel, multi-threaded, multicore powerful processors with high memory bandwidth. GPUs are used in a variety of intensive computing applications. The combination of highly parallel architecture and high memory bandwidth makes GPUs a potentially promising technology for effective real-time processing for High Energy Physics (HEP) experiments. However, not much is known of their performance in real-time applications that require low latency, such as the trigger for HEP experiments. We describe an R and D project with the goal to study the performance of GPU technology for possible low latency applications, performing basic operations as well as some more advanced HEP lower-level trigger algorithms (such as fast tracking or jet finding). We present some preliminary results on timing measurements, comparing the performance of a CPU versus a GPU with NVIDIA's CUDA general-purpose parallel computing architecture, carried out at CDF's Level-2 trigger test stand. These studies will provide performance benchmarks for future studies to investigate the potential and limitations of GPUs for real-time applications in HEP experiments.

43 PARTICLE ACCELERATORS↗