Search NASA⌕ Search

Engineering topics

Liu, Tianyu

Publications and source records attributed to Liu, Tianyu.

At least 19 records

Boosting Tin Perovskite Solar Cell Performance via Light-Induced Interface Doping

Continuous breakthroughs have been achieved in the photoelectric conversion efficiency (PCE) of tin-based perovskite solar cells (TPSCs) in recent years. Inspired by performance improvements observed during device storage, we identified beneficial light-induced interface doping (LIID) in the TPSCs. In situ analyses using X-ray photoelectron spectroscopy and ultraviolet photoelectron spectroscopy reveal that ion migration and oxidation at the interface induce beneficial doping effects, enhancing carrier transport and significantly boosting device performance. By implementing specific illumination techniques or maximum power point tracking (MPPT) methods to achieve LIID, we increased the open-circuit voltage while maintaining a high short-circuit current, reaching a PCE of up to 14.91%. Furthermore, this efficiency was sustained at 70% of its maximum value after nearly 900 h of continuous operation. Our study introduces a novel approach to addressing energy band mismatch, paving the way for improved efficiency in tin-based perovskite solar cells.

Sun, Mulin↗

Flexible Soft X-Ray Image Sensors based on Metal Halide Perovskites With High Quantum Efficiency

Soft X-ray imaging is a powerful tool to explore the structure of cells, probe material with nanometer resolution, and investigate the energetic phenomena in the universe. Conventional soft X-ray image sensors are by and large Si-based charge coupled devices that suffer from low frame rates, complex fabrication processes, mechanical inflexibility, and required cooling below -60 °C. Here, a soft X-ray photodiode is reported based on low-cost metal halide perovskite with comparable performance to commercial Si-based device. Nanothrough network electrode minimized the optical loss due to the shadowing of insensitive layers, while a multidimensional perovskite heterojunction is generated to reduce the photo-generated carrier loss. Further, this strategy promoted a record quantum efficiency of 8 × 10 3 % without cooling, several orders of magnitude greater than the previously achieved. Flexible and curved soft X-ray imaging arrays are fabricated based on this high-performance device structure, demonstrating stable soft X-ray response and sharp imaging capabilities. This work highlights the low-cost and efficient perovskite photodiode as a strong candidate for the next-generation soft X-ray image sensors.

36 MATERIALS SCIENCE↗

Reconfigurable Grating Diffraction Structural Color in Self-Assembled Colloidal Crystals

Self-assembled colloidal crystals display structural colors due to light diffracted from their microscale, ordered structure. This color arises due to Bragg reflection (BR) or grating diffraction (GD); the latter mechanism is much less explored than the former. Here the design space for generating GD structural color is identified and its relative advantages are demonstrated. Electrophoretic deposition is used to self-assemble crystals with fine crystal grains from colloids of diameter 1.0 µm. The structural color in transmission is tunable across the full visible spectrum. The optimum optical response—represented by both color intensity and saturation—is observed at low layer number (≤5 layers). The spectral response is well predicted by Mie scattering of the crystals. Taken together, the experimental and theoretical results demonstrate that vivid grating colors with high color saturation can be produced from thin layers of micron-sized colloids. These colloidal crystals extend the potential of artificial structural color materials.

42 ENGINEERING↗

Direct ink writing of organic and carbon aerogels

Additive manufacturing is used to overcome inherent aerogel limitations. 3D printed aerogels simultaneously exhibit large capacitance and fast ion transport in millimeter-thick electrodes.

Chandrasekaran, Swetha↗

Performance study of atomic tally methods for GPU-accelerated Monte Carlo dose calculation - 25352

Over the past several years, the graphics processing unit (GPU) technology has rapidly gained ground in scientific computing due to its outstanding performance and programmability. GPU implementation of Monte Carlo radiation transport for dose calculations has been reported by many investigators. The majority of these studies adopted single-precision floating point format because of the higher peak floating point operations per second (FLOPS) the GPUs can deliver than double-precision. It has been known that calculation using single-precision is more prone to numerical round-off errors, especially when a single tally data is accumulated 'atomically' and repeatedly by thousands of GPU threads. To mitigate this problem, the least intrusive solution in theory is to replace the single-precision atomic-add tally function with a double-precision version. However, the complexity lies in the fact that some GPUs (Nvidia GPUs prior to the Pascal generation; all current AMD GPUs) do not readily offer such double-precision function at hardware level, and that software emulation is too slow to use if not optimized properly. This paper discusses several atomic-add tally methods with reduced numerical errors used throughout ARCHER development. The original software-based compare-and-swap method (CAS) was shown to be inefficient due to high intra-warp thread contention, whereas the improved software-based warp-aggregated method (WAG) and Kahan summation method (KAS) eliminated the thread contention and performed very well on Kepler and Maxwell GPUs, being more than 13 times faster than CAS in our tests. The hardware-based (HB) double-precision atomic-add feature available on Pascal and Volta GPUs exceeded software emulation and offered the best performance universally, so did WIB, a combination of WAG and HB methods. It was also shown that in a single-precision dose engine, KAS managed to maintain high reliability when the single-precision atomic-add tally underestimated the dose by 25%. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of ARCHER towards clinical use: modeling and simulation of Varian Linac for radiation therapy dose calculations - 25449

Monte Carlo particle transport methods are well recognized as the most accurate approach to dose calculations for radiation therapy treatment planning. However, the lengthy calculation time has prevented Monte Carlo methods from being applied to dose calculations in the planning of radiation therapy. Recently, the emerging parallel computing hardware accelerators, such as general-purpose Graphics Processing Unit (GPU), have significantly boosted the performance of Monte Carlo codes. The accuracy of a clinical dose engine depends greatly on the accuracy of source term modeling and the methodology of dose calculations. Hence, in this study, an efficient and accurate source model of the Varian TrueBeam{sup R} Linac is developed and integrated with a fast photon-electron transport module of the recently developed high-performance Monte Carlo code, ARCHER. The validity of the source model and the particle transport physics are verified with established dose calculation codes such as EGSnrc and validated with experimental measurements. To demonstrate the capability of the platform in clinical applications, three clinical treatment plans (the lung, breast, and prostate) are simulated and analyzed. From the perspective of performance, the entire simulation of each clinical plan, starting from the source modeling to the end of particle transport within the patient phantom, can be finished in less than one minute using a single Titan X GPU card with 1% statistical error. In comparison, the same cases take the EGSnrc code hundreds of CPU hours to finish. The results suggest that this new version of ARCHER code has been successfully developed and tested as a clinically deployable dose engine for external photon beam IMRT plans in the clinical setting. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Introduction

Growing awareness of increasing global population and energy demand, diminishing supplies of fossil fuels, proliferating environmental pollution, and climate change has driven rapid developments in materials research in energy conversion and storage. At present time this area of study offers new solutions to these daunting challenges, from ensuring a steady energy stream produced by sustainable energy (e.g., solar, tidal and wind energy) to capturing and converting green-house gases to value-added products.

36 MATERIALS SCIENCE↗

Strong Modulation of Spin Currents in Bilayer Graphene by Static and Fluctuating Proximity Exchange Fields

Two-dimensional materials provide a unique platform to explore the full potential of magnetic proximity-driven phenomena, which can be further used for applications in next-generation spintronic devices. Of particular interest is to understand and control spin currents in graphene by the magnetic exchange field of a nearby ferromagnetic material in graphene–ferromagnetic-insulator (FMI) heterostructures. Here, we present the experimental study showing the strong modulation of spin currents in graphene layers by controlling the direction of the exchange field due to FMI magnetization. Owing to clean interfaces, a strong magnetic exchange coupling leads to the experimental observation of complete spin modulation at low externally applied magnetic fields in short graphene channels. Additionally, we discover that the graphene spin current can be fully dephased by randomly fluctuating exchange fields. This is manifested as an unusually strong temperature dependence of the nonlocal spin signals in graphene, which is due to spin relaxation by thermally induced transverse fluctuations of the FMI magnetization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Supercapacitors Based on Three-Dimensional Hierarchical Graphene Aerogels with Periodic Macropores

Graphene is an atomically thin, two-dimensional (2D) carbon material that offers a unique combination of low density, exceptional mechanical properties, thermal stability, large surface area, and excellent electrical conductivity. Recent progress has resulted in macro-assemblies of graphene, such as bulk graphene aerogels for a variety of applications. However, these three-dimensional (3D) graphenes exhibit physicochemical property attenuation compared to their 2D building blocks because of one-fold composition and tortuous, stochastic porous networks. These limitations can be offset by developing a graphene composite material with an engineered porous architecture. In this work, we report the fabrication of 3D periodic graphene composite aerogel microlattices for supercapacitor applications, via a 3D printing technique known as direct-ink writing. The key factor in developing these novel aerogels is creating an extrudable graphene oxide-based composite ink and modifying the 3D printing method to accommodate aerogel processing. The 3D-printed graphene composite aerogel (3D-GCA) electrodes are lightweight, highly conductive, and exhibit excellent electrochemical properties. In particular, the supercapacitors using these 3D-GCA electrodes with thicknesses on the order of millimeters display exceptional capacitive retention (ca. 90% from 0.5 to 10 A·g –1 ) and power densities (>4 kW·kg –1 ) that equal or exceed those of reported devices made with electrodes 10–100 times thinner. This work provides an example of how 3D-printed materials, such as graphene aerogels, can significantly expand the design space for fabricating high-performance and fully integrable energy storage devices optimized for a broad range of applications.

36 MATERIALS SCIENCE↗

In vitro dose measurements in a human cadaver with abdomen/pelvis CT scans

Purpose: To present a study of radiation dose measurements with a human cadaver scanned on a clinical CT scanner. Methods: Multiple point dose measurements were obtained with high-accuracy Thimble ionization chambers placed inside the stomach, liver, paravertebral gutter, ascending colon, left kidney, and urinary bladder of a human cadaver (183 cm in height and 67.5 kg in weight) whose abdomen/pelvis region was scanned repeatedly with a multidetector row CT. The flat energy response and precision of the dosimeters were verified, and the slight differences in each dosimeter's response were evaluated and corrected to attain high accuracy. In addition, skin doses were measured for radiosensitive organs outside the scanned region with OSL dosimeters: the right eye, thyroid, both nipples, and the right testicle. Three scan protocols were used, which shared most scan parameters but had different kVp and mA settings: 120-kVp automA, 120-kVp 300 mA, and 100-kVp 300 mA. For each protocol three repeated scans were performed. Results: The tube starting angle (TSA) was found to randomly vary around two major conditions, which caused large fluctuations in the repeated point dose measurements: for the 120-kVp 300 mA protocol this angle changed from approximately 110° to 290°, and caused 8% − 25% difference in the point dose measured at the stomach, liver, colon, and urinary bladder. When the fluctuations of the TSA were small (within 5°), the maximum coefficient of variance was approximately 3.3%. The soft tissue absorbed doses averaged from four locations near the center of the scanned region were 27.2 ± 3.3 and 16.5 ± 2.7 mGy for the 120 and 100-kVp fixed-mA scans, respectively. These values were consistent with the corresponding size specific dose estimates within 4%. The comparison of the per-100-mAs tissue doses from the three protocols revealed that: (1) dose levels at nonsuperficial locations in the TCM scans could not be accurately deduced by simply scaling the fix-mA doses with local mA values; (2) the general power law relationship between dose and kVp varied from location to location, with the power index ranged between 2.7 and 3.5. The averaged dose measurements at both nipples, which were about 0.6 cm outside the prescribed scan region, ranged from 23 to 27 mGy at the left nipple, and varied from 3 to 20 mGy at the right nipple over the three scan protocols. Large fluctuations over repeated scans were also observed, as a combined result of helical scans of large pitch (1.375) and small active areas of the skin dosimeters. In addition, the averaged skin dose fell off drastically with the distance to the nearest boundary of the scanned region. Conclusions: This study revealed the complexity of CT dose fluctuation and variation with a human cadaver.

60 APPLIED LIFE SCIENCES↗

Comparisons of dosimetric accuracy and calculation time of ARCHER and MCNP5 codes for the Ir-192 brachytherapy case - Paper 1

In the last decade, the graphics processing unit (GPU) technology has emerged as a viable player in high-performance computing. A GPU card is designed to carry out thousands of single instructions simultaneously, showing unprecedented computing power when compared with the traditional CPU technology. It has been proved that some computationally intensive programs can be accelerated drastically on the GPUs including Monte Carlo simulations. Unfortunately, existing production Monte Carlo codes cannot be easily ported to the GPU environment. To address the needs, a new Monte Carlo code ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environment) is being developed at Rensselaer Polytechnic Institute, employing the latest GPU and the Intel Xeon Phi coprocessor technologies. We can execute the code which was written using C and C++ on both CPU and GPU platforms. The ARCHER GPU code was written in CUDA C 5.0 and was tested on the Tesla M2090. There have been a few studies testing the ARCHER GPU code on several different platforms. In particular, Su et al has tested the ARCHER for external-beam radiation treatment 20 MeV monoenergetic monodirectional parallel electron beam. The comparison of the calculation results between EGSnrc and ARCHERGPU was impressive. A remarkable 224- fold speed-up factor was obtained using a NVIDIA Tesla M2090 GPU compared to a CPU. In this study, we applied the ARCHER code to dose calculation for a relatively new procedure, called accelerated partial breast irradiation (APBI) brachytherapy. The APBI brachytherapy dose calculation was based on RPI-AF phantom which is a 3D heterogeneous patient model. We then compared the dosimetric accuracy and calculation times of ARCHER and MCNP5 to gain insight into the accuracy and speedup of the GPU-based ARCHER code. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Parallel Monte Carlo Methods for Heterogeneous Hardware Computer Systems Using GPUs and Coprocessors: Recent Development of ARCHER Code - Paper 54

Traditional methods of accelerating Monte Carlo (MC) calculations typically use CPUs as the computing unit. The parallelism is based upon multithreading on a multi-core processor, and message passing interface (MPI) across many processors and nodes. In recent years, the hardware accelerators have been introduced by the high performance computing industry as an alternative approach to achieve massive parallelism. Hardware accelerators have the advantage of high Floating-point Operations Per Second (FLOPS) and high energy efficiency. Examples include graphics processing units (GPUs) and coprocessors. Compute-intensive programs can be off-loaded to them to be concurrently executed by hundreds or thousands of active threads. Existing production MC codes, however, cannot be directly compiled or executed on the new platforms. It is therefore necessary to rewrite or redevelop the code using the hardware accelerator specific programming models and APIs. Several studies have been conducted on using GPUs to accelerate MC calculations in reactor analysis and medical physics. In this paper, we present the recent progress at Rensselaer Polytechnic Institute (RPI) in developing a new parallel MC code called ARCHER (Accelerated Radiation-transport Computations in Heterogeneous Environments) for coupled photon-electron transport simulations. The code is designed as a test bed to evaluate the efficacy of heterogeneous computing systems for low-cost MC-based radiation dosimetric calculations. The code has three variants corresponding to three parallel hardware platforms: ARCHER-CPU (multi-core CPU), ARCHER-GPU (Nvidia GPU) and ARCHER-COP (Intel Xeon Phi coprocessor). The code has been used for several applications, including CT imaging dosimetry, radiotherapy dosimetry and radiation shielding design. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗