Search NASA⌕ Search

Engineering topics

Liu, Xiaoli

Publications and source records attributed to Liu, Xiaoli.

A review of antimicrobial implications for improving indoor air quality

The frequent outbreak of infectious respiratory diseases, such as the recent COVID-19 epidemic, raised the importance of indoor air quality. Removing microorganisms from indoor air is critical to improve indoor air quality. Numerous studies in recent years have been published on developing antimicrobial materials and technologies for antibacterial and antiviral applications. Further, this study critically reviews the recent antimicrobial advances for improving indoor air quality. This paper provides a comprehensive analysis of the antimicrobial mechanisms, development of materials, and deployment strategies, as well as a performance evaluation of the antimicrobial implication for indoor air quality. Furthermore, the challenges and opportunities of future research directions are also highlighted.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling and Analysis of a Heat Pump Clothes Dryer with Thermal Energy Storage

Clothes drying is an energy-intensive process that causes significant electricity consumption and carbon emissions in the US. Approximately 83% of Households in the US own a tumble clothes dryer at home and 80% of dryers are electrical resistance dryers with low energy efficiency. Heat pump technology makes it possible for highly efficient and clean drying. Additionally, the ventless design of heat pump clothes dryers (HPCD) provides more installation flexibility. HPCD involves three primary mediums: wet clothes, a closed air loop, and a refrigerant circuit. The evaporator is used to dehumidify the wet air and the condenser is used to re-heat the dry air. One of the critical technological barriers to HPCD market penetration is its long drying time, primarily due to the relatively low discharging temperature and the slow response during the warm-up period. In this study, the thermal energy storage (TES) technology is adopted to address this challenge by providing pre-heating of air prior to the condenser to increase the operating temperature of the process air. The heat pump will charge the phase change material (PCM) in the TES device with heating energy during clothes washing and the PCM will discharge the stored heat to facilitate air heating during clothes drying. To analyze the optimal design and potential for energy saving and drying time reduction, a mathematical model of the HPCD system was developed. The HPCD is a highly dynamic system with a coupled heat and mass transfer and heat pumping cycle. This paper provides solutions to simulate the transient behavior of the system while maintaining low computational cost. The modeling result indicates reduced energy consumption and drying time by integrating TES with HPCD, as compared to electrical resistance dryers. The study can provide significant insights into improving building flexibility with TES and smart appliances.

Liu, Xiaoli↗

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE↗

Synthesis of Red, Green, and Blue Carbon Quantum Dots and Construction of Multicolor Cellulose-Based Light-Emitting Diodes

Light-emitting diodes (LEDs) are widely used in lighting and display applications. Carbon quantum dots (CQDs), which have high biocompatibility, high resistance to photobleaching, and full-spectrum luminescence, have inherent advantages as fluorescent materials for LED devices. Herein, multicolor CQDs are prepared by a new reagent engineering strategy due to the difference of effective conjugate length and the surface electron-withdrawing groups of CQDs. White CQDs are realized by mixing blue, green, and red CQDs proportionally. Then, the aggregation-caused quenching phenomenon of CQDs is suppressed through the hydrogen-bonding network of cellulose nanofibrils (CNFs). Multicolor fluorescent films are prepared from CQDs and CNFs by simple mixing and casting methods. Finally, thin-film encapsulation based on the photosensitive resin ABPE-10 coating can be realized and rapidly assembles into fluorescent films with different light-emitting colors into LED devices, leading to have superior thermal performance compared with conventional LEDs. White LEDs have excellent white-light illumination performance, with Commission Internationale de L’Eclairage color coordinates of (0.33, 0.37), a correlated color temperature of 5688 K, and a color rendering index of 86. This strategy provides a convenient and scalable pathway for low-cost, environmentally friendly, and high-performance CQDs-based LEDs.

42 ENGINEERING↗

Quaternary ammonium salt coated air filter for bioaerosol removal from building indoor air

Developing air filters with biocidal ability is important to protect the public from infectious respiratory diseases. A simple spray-coating approach was devised to fabricate antimicrobial air filters to remove bioaerosols. Here, the commercial antimicrobial agent Goldshield 75 was coated on the air filters through covalent immobilization, endowing the fabricated filter with long-lasting biocidal ability. All coated filters significantly inhibited both Gram-positive bacteria (Micrococcus luteus) and Gram-negative bacteria (Escherichia coli). The antibacterial ability of the coated filters is similar to the commercial AeraSafe antibacterial filter. The coated filter showed over 99.9 % antibacterial efficiency 3 months after the application of the coating. Both bacterial and virus filtration efficiencies of coated charged polypropylene filter were higher than 99.9 %. The coating did not have much effect on the NaCl aerosol filtration efficiency of the filters. This simple spray-coating strategy is a practical method for producing antimicrobial air filters for the prevention of infectious respiratory diseases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental results of embedded phase change material capsules for increasing the performance of a wrapped heat pump water heater

Herein, to enhance the capacity of heat pump water heaters (HPWHs), high energy density phase change material (PCM) was used in two experimentally tested HPWH prototypes. Preliminary findings showed that in the PCM, stored thermal potential energy could be effectively converted into sensible heat in the water over a slight temperature difference, with the goal of increasing the capacity of hot water above a desired cut-off temperature. This exchange of energy results in an increased amount of hot water necessary for mixing at the location utilized by the consumer. It was also found that for a wrapped HPWH, there was an average increase of 27.7% in the capacity when 7.6 L of novel PCM filled spherical capsules were added to a 22.7 L tank downstream of the HPWH. In the second design (Beta), PCM capsules were immersed into the tank with a cylindrical geometry, and the UEF was increased by 5.5% over the baseline HPWH test result. As for the Beta design, heat loss was reduced significantly compared to a typical HPWH and the Alpha design. Food-grade PCMs were selected as appropriate. The novel encapsulation design increased the effective conductivity inside the capsule by adding metal fins.

42 ENGINEERING↗

Lignin-based carbon quantum dots with high fluorescence performance prepared by supercritical catalysis and solvothermal treatment for tumor-targeted labeling

The poor fluorescence performance of lignin-based carbon quantum dots (L-CQDs) prepared using the bottom-up method has hindered their development. Here, in this study, a two-step strategy was proposed to efficiently enhance the fluorescence properties of L-CQDs. Lignin was first cracked using an ethanol supercritical/noble metal catalyst; then, the L-CQDs were prepared with the cracked lignin fragments as carbon precursors without adding any modified reagents. Compared with the OL-CQDs prepared by the traditional one-pot hydrothermal method, the L-CQDs-1 prepared from CL-1 containing much low molecular weight compounds, and have photoluminescence (increased from 63 to 975) and excellent up-conversion photoluminescence (enhanced by 16.3 to 963), which significantly enhanced by about 15 times and 60 times, respectively. They can emit bright blue fluorescence under both ultraviolet and near-infrared light irradiation owing to a large amount of surface defects caused by the rich compound composition. When L-CQDs-1 were combined with, and quenched by folic acid (FA), the prepared FA@L-CQDs-1 show the ability to target and label tumor cells. This study opens new avenues for the preparation of L-CQDs with high fluorescence performance using lignocellulosic material without heteroatom additives.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental performance analysis of a dual source heat pump integrated with thermal energy storage

To mitigate disturbances to the electric grid resulting from the growing penetration of intermittent and decentralized renewable generation, a dual-source (air source and ground source) heat pump (DSHP) integrated with thermal energy storage (TES) was developed. The DSHP can use either ambient air or the shallow subsurface of the ground to provide space heating or space cooling to the building as the conventional heat pump and produce hot/cold water for charging TES. Using dual sources (air and ground) can reduce the required size of the expensive ground heat exchangers while retaining high energy efficiency. During the off-peak period, the DSHP cools/heats the TES with low-cost electricity or overproduced renewable power. The stored cooling/heating energy in the TES is released during peak hours of the electric grid to meet the thermal demands of the building without consuming electricity to run the DSHP. A 2-ton (7 kW) prototype DSHP was developed and integrated with a 50-gallon (189 L) TES tank filled with a phase change material. Field tests were conducted to characterize the performance of the integrated system operating in various operation modes.

Wang, Lingshi↗

DYNC1H1 regulates NSCLC cell growth and metastasis by IFN-γ-JAK-STAT signaling and is associated with an aberrant immune response

Highlights: • DYNC1H1 is upregulated and its high expression predicted poor outcomes in NSCLC. • Loss of function of DYNC1H1 inhibits cell growth and metastasis of NSCLC cells in vitro. • DYNC1H1 knockdown inhibited metastasis of NSCLC cells in vivo. • DYNC1H1 loss of function suppresses IFN-γ-JAK-STAT signaling pathway in NSCLC. • DYNC1H1 expression is correlated with aberrant immune response in NSCLC indicated by analysis of TCGA immune data. It is urgent to identify new biomarkers and therapeutic targets to ameliorate the clinical prognosis of patients with lung cancer. The functional significance and molecular mechanism of dynein cytoplasmic 1 heavy chain 1 (DYNC1H1) in nonsmall cell lung cancer (NSCLC) progression is still elusive. In our current study, publicly available data and Western blotting experiments confirmed that DYNC1H1 expression was upregulated in lung cancer samples compared with noncancerous samples. Quantitative real-time PCR (qPCR) results indicated that high DYNC1H1 expression in lung cancer tissues was significantly associated with clinical tumor stage and distal metastasis; moreover, its high expression was negatively correlated with prognosis. Functional experiments demonstrated that DYNC1H1 loss of function caused a significant decrease in cell viability and cell proliferative ability, inhibition of the cell cycle, and promotion of both migration potential and invasion potential in vitro. Animal experiments by tail vein injection of lung cancer cells showed that DYNC1H1 knockdown significantly decreased lung cancer metastasis. Mechanistically, the results from a human protein array showed changes in the IFN-γ-JAK-STAT signaling pathway, and analysis of The Cancer Genome Atlas (TCGA) immune data demonstrated that disturbance of the immune microenvironment might be involved in the impaired growth and metastatic ability mediated by DYNC1H1 loss in NSCLC. DYNC1H1 might serve as a promising biological marker of prognosis and a potential clinical therapeutic target for patients with NSCLC.

60 APPLIED LIFE SCIENCES↗

An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant

As a promising alternative to inefficient vapor-compression-based air conditioning, liquid desiccant dehumidification uses a liquid desiccant in contact with the humid air absorbing the moisture. However, it has not gained much market share due to the issues related to the carryover, corrosion, fouling, and crystallization of liquid desiccant. The research has developed a new membrane-based exchanger, which uses a non-corrosive ionic liquid desiccant and nonporous tubular membranes to address these issues. As the second generation of the prototype, the new exchanger was tested at various operating conditions. According to the experimental data, when it is used in the dehumidification loop, the new membrane-based exchanger achieves a specific vapor transportation rate of 778.6 g/(h–m 2 ) and an average water vapor flux of 0.316 g/(h-m 2 -Pa), which is a significant improvement compared with the previous designs using nonporous membranes. It also achieved a comparable or even better dehumidification performance compared with the dehumidifiers that use porous membrane and conventional liquid desiccants. However, the regeneration performance is not as good as its dehumidification. It is mainly caused by the high operating temperature required in the regeneration loop. The experimental data and findings provide first-hand experimental data and enhance the understanding of advanced membrane-based ionic liquid desiccant systems.

42 ENGINEERING↗

Numerical modeling and performance analysis of a membrane-based air dehumidifier using ionic liquid desiccant

Membrane-based Liquid Desiccant Air Dehumidifier (MLDAD) has the potential to overcome the shortcomings of the conventional open-tower liquid desiccant air dehumidifier. The MLDAD uses membranes with high water vapor permeability to separate air stream from the liquid desiccant and thus eliminates carry-over and the resulting corrosion issues. Recently, the ionic liquid desiccant becomes a promising alternative to conventional liquid desiccant. The ionic liquid desiccant has a large potential of dehumidification, which is also non-corrosive to metals and non-crystallizable. A two-dimensional numerical heat and mass transfer model of the MLDAD using a recently identified ionic liquid desiccant, [EMIM]OAc, is presented here. This model can simulate the performance of the MLDAD with various designs, including different selections of liquid desiccant and membrane materials, dimensions of the MLDAD, and flow patterns. For porous membranes, this model accounts for several micro-scale mass transfer mechanisms of vapor transportation across the membrane. It can also model the mass transfer performance of dehumidifiers using non-porous membranes based on the experimentally measured membrane permeance. The numerical model was validated against the performance data available from literature and experimental tests. The maximum discrepancy of the latent effectiveness between the measured and the model-predicted results was about 6% when porous membranes were used. A parametric study was conducted with the numerical model. Finally, the results indicated that the membrane permeability, air path height, and solution to air mass ratio were the most critical parameters, determining the dehumidification performance of the MLDAD.

42 ENGINEERING↗