Budget-Constrained Sizing of Renewable and Energy Storage Systems for Farm-Scale Ammonia Production Within the Food-Energy-Water Nexus

In the transition toward sustainable agriculture, farms have emerged as eco-friendly pioneers, harnessing clean hybrid wind and solar systems to improve farm performance. A concern in this paradigm is the effective sizing of renewable energy systems to ensure optimal energy use within budget considerations. This research focuses on optimizing renewable energy sizing in small-scale ammonia production to meet specific farm demands and enhance local resilience, emphasizing the interplay between environmental and economic factors. These findings promise increased energy efficiency and sustainability in this innovative agricultural sector. Additionally, our approach considers small-scale ammonia plant needs and the dynamic relationships between ammonia, water, and farm demands. Simulations demonstrate substantial cost savings in farm electricity consumption. Specifically, scenarios with renewable energy integration in the farm can reduce at least 13% electricity cost compared to a grid-dependent system in the 15-year simulation.

ammonia↗

Frequency Nadir Constrained Unit Commitment for High Renewable Penetration Island Power Systems

The process of energy decarbonization in island power systems is accelerated due to the swift integration of inverter-based renewable energy resources (IBRs). The unique features of such systems, including rapid frequency changes resulting from potential generation outages or imbalances due to the unpredictability of renewable power, pose a significant challenge in maintaining the frequency nadir without external support. This paper presents a unit commitment (UC) model with data-driven frequency nadir constraints, including either frequency nadir or minimum inertia requirements, helping to limit frequency deviations after significant generator outages. The constraints are formulated using a linear regression model that takes advantage of real-world, year-long generation scheduling and dynamic simulation data. The efficacy of the proposed UC model is verified through a year-long simulation in an actual island power system using historical weather data. The alternative minimum inertia constraint, derived from actual system operation assumptions, is also evaluated. Findings demonstrate that the proposed frequency nadir constraint notably improves the system's frequency nadir under high photovoltaic (PV) penetration levels, albeit with a slight increase in generation costs, when compared to the alternative minimum inertia constraint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different datasets, i.e., 1) the unit generation dataset and 2) the system total inertia and headroom dataset, for the prediction of the frequency nadir. The training and testing datasets are generated through extensive generation scheduling simulations using Multi-timescale Integrated Dynamic and Scheduling (MI-DAS) toolbox on the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. Numerical results show that all five machine learning methods perform well in predicting the nadir frequency of the system. Among them, the gradient boosting and the XGBoost are clear winners yielding the best prediction accuracy in terms of four evaluation metrics.

data driven↗

A Comparison of Machine Learning Methods for Frequency Nadir Estimation in Power Systems: Preprint

An increasing penetration level of inverter-based renewable energy resources changes the inertia of power systems, posing challenges for maintaining the desired system frequency stability. An accurate frequency nadir estimation is crucial for power system operators to prepare preventive actions against large frequency excursions. In this paper, five machine learning methods - linear regression, gradient boosting, support vector regression, an artificial neural network, and XGBoost - are applied to two different sets of preprocess data for the prediction of the frequency nadir in the Western Electricity Coordinating Council 240-bus system with high renewable penetration levels. The training and testing data sets are collected by extensive generation scheduling simulations on the Multi-timescale Integrated Dynamic and Scheduling (MIDAS) toolbox. Numerical results show that all five machine learning methods can achieve high performance accuracy for power system nadir frequency estimation. Among them, the gradient boosting and the XGBoost are clear winners by providing the best prediction accuracy.

data driven↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of model predictive control-enabled home energy management on large-scale distribution systems with photovoltaics

Residential customers use more than one-quarter of the electricity in the world. Optimally managing home energy consumption is an effective way of easing the operational challenges facing the electric grid with increasing solar photovoltaics (PV). This paper studies the impact of the future proliferation of home energy management systems (HEMS) in the presence of PV on large-scale distribution systems. First, we present a stochastic HEMS model that minimizes residential customers' thermal discomfort and energy costs under uncertainty. The HEMS model schedules the optimal operations of residential appliances in the presence of PV within a mixed-integer linear programming-based model predictive control framework that links the proposed HEMS to a quasi-steady-state time-series simulation tool. Additionally, extensive simulations are conducted for a stand-alone residential home using two tariff structures and for 1977 homes on an 8,500-node distribution feeder. Simulation results quantify the impact of the future proliferation of HEMS on the large-scale distribution system with PV.

14 SOLAR ENERGY↗

Load Margin Constrained Moving Target Defense against False Data Injection Attacks

Cyber physical security of power systems with high penetration of renewable generation has attracted attention from researchers. One critical issue is that cyber-physical attacks, disguised as uncertain renewable generation, can target conventional power system state estimation (SE). Moving target defense (MTD) is a promising defense strategy to detect stealthy false data injection (FDI) attacks against SE. However, all existing studies myopically perturb the reactance of transmission lines equipped with distributed flexible AC transmission system (D-FACTS) devices without adequately considering the system voltage stability. Exacerbated by the renewable generation uncertainty, existing MTD may cause voltage instability when the power grid is under stress. To address this issue, we propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow. We utilize the sensitivity matrix of power injection to line impedance, on which an optimization problem for maximizing load margin is formulated. This framework is validated on the IEEE 14-bus system and the IEEE 118-bus system, in which net load redistribution attacks are launched by sophisticated attackers. Steady-state simulations and dynamic simulations on PSS/E show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. The impact of the proposed method on attack detection effectiveness is also revealed.

Zhang, Hang↗

Isoorientin induces apoptosis through mitochondrial dysfunction and inhibition of PI3K/Akt signaling pathway in HepG2 cancer cells

Isoorientin (ISO) is a flavonoid compound that can be extracted from several plant species, such as Phyllostachys pubescens, Patrinia, and Drosophyllum lusitanicum; however, its biological activity remains poorly understood. The present study investigated the effects and putative mechanism of apoptosis induced by ISO in human hepatoblastoma cancer (HepG2) cells. The results showed that ISO induced cell death in a dose-dependent manner in HepG2 cells, but no toxicity in human liver cells (HL-7702) and buffalo rat liver cells (BRL-3A) treated with ISO at the indicated concentrations. ISO-induced cell death included apoptosis which characterized by the appearance of nuclear shrinkage, the cleavage of poly (ADP-ribose) polymerase (PARP) and DNA fragmentation. ISO significantly (p < 0.01) increased the Bax/Bcl-2 ratio, disrupted the mitochondrial membrane potential (MMP), increased the release of cytochrome c, activated caspase-3, and enhanced intracellular levels of reactive oxygen species (ROS) and nitric oxide (NO). In addition, ISO effectively inhibited the phosphorylation of Akt and increased FoxO4 expression. The PI3K/Akt inhibitor LY294002 enhanced the apoptosis-inducing effect of ISO. However, LY294002 markedly quenched ROS and NO generation and diminished the protein expression of heme peroxidase enzyme (HO-1) and inducible nitric oxide synthase (iNOS). Furthermore, the addition of a ROS inhibitor (N-acetyl cysteine, NAC) or iNOS inhibitor (N-[3-(aminomethyl) benzyl] acetamidine, dihydrochloride, 1400W) significantly diminished the apoptosis induced by ISO and also blocked the phosphorylation of Akt. These results demonstrated for the first time that ISO induces apoptosis in HepG2 cells and indicate that this apoptosis might be mediated through mitochondrial dysfunction and PI3K/Akt signaling pathway, and has no toxicity in normal liver cells, suggesting that ISO may have good potential as a therapeutic and chemopreventive agent for liver cancer. Highlights: ► Isoorientin induced apoptosis in HepG2 cells. ► Isoorientin disordered mitochondrial function and inhibited PI3K/AKt pathway. ► PI3K/Akt pathway mediated mitochondrial dysfunction via Bcl-2 family members. ► Isoorientin stimulated the intracellular ROS and NO generation in HepG2 cells. ► ROS and NO initiated mitochondria dysfunction and involved in PI3K/Akt pathway.