Emodin ameliorates myocardial fibrosis in mice by inactivating the ROS/PI3K/Akt/mTOR axis
Not Available
Engineering topics
Publications and source records attributed to Liu, Yunchuan.
Not Available
Timely detection of power system events is a crucial task, which can facilitate the implementation of remedial actions to improve reliability, resiliency, and security of the system. Meanwhile, the widespread deployment of phasor measurement units (PMUs) makes it possible to develop data-driven event detection techniques. However, relying purely on data without incorporating domain knowledge for the event detection task in power systems poses substantial security and stability risks due to issues associated with data misinterpretation and model accuracy. In this regard, we propose a real-time event detection method using real-world PMU data by incorporating domain knowledge to adequately capture the event signatures. Specifically, we track the change in rank signatures of PMU data to accurately localize the events. To optimize the detection process, we incorporate an offline Bayesian optimization algorithm to tune the parameters by efficiently searching for the best values. The experiments using the real-world PMU dataset from a U.S. interconnection show that the proposed event detection approach can efficiently detect the events from PMU data streams with high accuracy.
This paper studies event classification using imperfect real-world phasor measurement unit (PMU) data with scarce event types (labels). By investigating the real-world PMU data, it is observed that most real-world PMU data's event type is unknown, which makes it challenging to directly use such dataset to build event classifiers as existing classification techniques require high-quality training data with known event type (i.e., label). To address this challenge, a weakly supervised learning based event classification approach is developed, which can use noisy and low-quality PMU data for the training. First, data quality issues are fixed using data preprocessing techniques and then event features are constructed from the PMU data. Using these features, a series of labeling functions are learnt to generate initial estimates of the labels of large amounts of unlabeled PMU data. As the labeling functions are learnt using the same data with scarce labels, the label estimates from the labeling functions can be correlated, noisy, and bias. To enhance these initial estimates, a generative model is developed to characterize the dependencies among the estimated labels, based on which better labels are obtained for training event classifiers. Numerical experiments using the real-world dataset from the Western Interconnection of the U.S. power transmission grid show that the proposed weakly supervised event classifier trained using the dataset with only 5% labeled data can achieve 78.4% classification accuracy.
Here, this paper studies robust event classification using imperfect real-world phasor measurement unit (PMU) data. By analyzing the real-world PMU data, we find it is challenging to directly use this dataset for event classifiers due to the low data quality observed in PMU measurements and event logs. To address these challenges, we develop a novel machine learning framework for training robust event classifiers, which consists of three main steps: data preprocessing, fine-grained event data extraction, and feature engineering. Specifically, the data preprocessing step addresses the data quality issues of PMU measurements (e.g., bad data and missing data); in the fine-grained event data extraction step, a model-free event detection method is developed to accurately localize the events from the inaccurate event timestamps in the event logs; and the feature engineering step constructs the event features based on the patterns of different event types, in order to improve the performance and the interpretability of the event classifiers. Based on the proposed framework, we develop a workflow for event classification using the real-world PMU data streaming into the system in real time. Using the proposed framework, robust event classifiers can be efficiently trained based on many off-the-shelf lightweight machine learning models. Numerical experiments using the real-world dataset from the Western Interconnection of the U.S power transmission grid show that the event classifiers trained under the proposed framework can achieve high classification accuracy while being robust against low-quality data.
This paper presents a machine learning method for event cause analysis to enhance situational awareness in distribution networks. The data streams are captured using time-synchronized high sampling rates synchro waveform measurement units (SWMU). The proposed method is formulated based on a machine learning method, the convolutional neural network (CNN). This method is capable of capturing the spatiotemporal feature of the measurements effectively and perform the event cause analysis. Several events are considered in this paper to encompass a range of possible events in real distribution networks, including capacitor bank switching, transformer energization, fault, and high impedance fault (HIF). The dataset for our study is generated using the real time digital simulator (RTDS) to simulate real-world events. The event cause analysis is performed using only one cycle of the voltage waveforms after the event is detected. The simulation results show the effectiveness of the proposed machine learning-based method compared to the state-of-the-art classifiers.
This paper presents an event classification in transmission grids. The convolutional neural network (CNN)-based classifier is proposed to capture the temporal similarity of time-synchronized data stream from phasor measurement units (PMUs). The proposed CNN is trained using Bayesian optimization to search for the best hyperparameters. The effectiveness of the proposed event classification is validated through the real-world dataset from the U.S. transmission grids. This dataset includes line outage, transformer outage, frequency, and oscillation events. The validation process also includes different PMU outputs, such as voltage magnitude, phase angle, current magnitude, frequency, and rate of change of frequency (ROCOF). The results show that ROCOF gives the best classification performance compared to other PMU outputs. In addition, it is shown that the classifier trained with a larger dataset has higher accuracy. Moreover, the superiority of the proposed method is validated through comparison with other state-of-the-art classification methods.
This paper proposes a tensor completion method for the recovery of missing phasor measurement unit (PMU) measurements. Tensor completion as the general case of matrix completion has attracted increasing attention in recent years. The imputation accuracy for the existing matrix completion methods may be significantly reduced when there are consecutive data losses across multiple data channels. To tackle this issue, we explore the multi-way characteristics of PMU measurements by using a tensor model. We leverage the low-rank property of the PMU measurements and formulate the missing PMU data recovery problem as a low-rank tensor completion problem. An efficient algorithm based on alternating direction method of multipliers (ADMM) is developed to solve the tensor completion problem. The experiments using the real PMU dataset show that the proposed method exhibits better imputation accuracy compared with the conventional data recovery methods.