Search NASA⌕ Search

Engineering topics

Liu, Yunlong

Publications and source records attributed to Liu, Yunlong.

Metaproteomics-informed stoichiometric modeling reveals the responses of wetland microbial communities to oxygen and sulfate exposure

Abstract Climate changes significantly impact greenhouse gas emissions from wetland soil. Specifically, wetland soil may be exposed to oxygen (O 2 ) during droughts, or to sulfate (SO 4 2- ) as a result of sea level rise. How these stressors – separately and together – impact microbial food webs driving carbon cycling in the wetlands is still not understood. To investigate this, we integrated geochemical analysis, proteogenomics, and stoichiometric modeling to characterize the impact of elevated SO 4 2- and O 2 levels on microbial methane (CH 4 ) and carbon dioxide (CO 2 ) emissions. The results uncovered the adaptive responses of this community to changes in SO 4 2- and O 2 availability and identified altered microbial guilds and metabolic processes driving CH 4 and CO 2 emissions. Elevated SO 4 2- reduced CH 4 emissions, with hydrogenotrophic methanogenesis more suppressed than acetoclastic. Elevated O 2 shifted the greenhouse gas emissions from CH 4 to CO 2 . The metabolic effects of combined SO 4 2- and O 2 exposures on CH 4 and CO 2 emissions were similar to those of O 2 exposure alone. The reduction in CH 4 emission by increased SO 4 2- and O 2 was much greater than the concomitant increase in CO 2 emission. Thus, greater SO 4 2- and O 2 exposure in wetlands is expected to reduce the aggregate warming effect of CH 4 and CO 2 . Metaproteomics and stoichiometric modeling revealed a unique subnetwork involving carbon metabolism that converts lactate and SO 4 2- to produce acetate, H 2 S, and CO 2 when SO 4 2- is elevated under oxic conditions. This study provides greater quantitative resolution of key metabolic processes necessary for the prediction of CH 4 and CO 2 emissions from wetlands under future climate scenarios.

59 BASIC BIOLOGICAL SCIENCES↗

Data-driven predictive probability density function control of fiber length stochastic distribution shaping in refining process

Pulp is the most important raw material in paper in paper industries, whose Fiber Length Stochastic Distribution (FLSD) shaping directly determines the energy consumption and paper quality of the subsequent papermaking processes. However, the mean and variance are insufficient to describe the output FLSD shaping, which display non-Gaussian distribution properties. Therefore, the traditional control, method based on the mean and variance of fiber length is difficult to control the FLSD shaping effectively. In this paper, a novel data-driven predictive probability density function (PDF) control method is proposed for output FLSD shaping in refining process. Primarily, in order to improve the approximation accuracy of the PDF employing RBF neural network, the parameters (center value and width) of each RBF basis functions are tuned via utilizing iterative learning control (ILC) law, and the corresponding estimations of weights law can be obtained. Secondly, considering that the conventional linear model of weights vector has drawbacks of low accuracy and weak generalization ability, random vector functional link networks (RVFLNs) based data driven nonlinear modelling method is employed to characterize the prediction model between the input variables and weights vector. Finally, in order to reduce the randomness of the output FLSD, a minimum entropy control method under mean constraint is employed to design the predictive PDF controller for the output FLSD shaping with the help of the established nonlinear stochastic distribution model. Both simulations and experiments are given to illustrate the effectiveness and practicability of the proposed method.

Probability debsity function, Fiber length distrib↗

Composite Robust $H_\infty$ Control for Uncertain Stochastic Nonlinear Systems with State Delay via Disturbance Observer

Here in this note, the robust stochastic stabilization and robust H_infinity control problems are investigated for uncertain stochastic time-delay systems with nonlinearity and multiple disturbances. By estimating the disturbance, which can be described by an exogenous model, a composite hierarchical control scheme is proposed that integrates the output of the disturbance observer with state feedback control law. Sufficient conditions for the existence of the disturbance observer and composite hierarchical controller are established in terms of linear matrix inequalities, which ensure the mean-square asymptotic stability of the resulting closed-loop system and the disturbance attenuation. It has been shown that the disturbance rejection performance can also be achieved. A numerical example is provided to show the potential of the proposed techniques and encouraging results have been obtained.

42 ENGINEERING↗

An Error-Entropy Minimization Algorithm for Tracking Control of Nonlinear Stochastic Systems with Non-Gaussian Variables

This paper presents an error-entropy minimization tracking control algorithm for a class of dynamic stochastic system. The system is represented by a set of time-varying discrete nonlinear equations with non-Gaussian stochastic input, where the statistical properties of stochastic input are unknown. By using Parzen windowing with Gaussian kernel to estimate the probability densities of errors, recursive algorithms are then proposed to design the controller such that the tracking error can be minimized. The performance of the error-entropy minimization criterion is compared with the mean-square-error minimization in the simulation results.

Entropy↗

A mass graph-based approach for the identification of modified proteoforms using top-down tandem mass spectra

Motivation: Although proteomics has rapidly developed in the past decade, researchers are still in the early stage of exploring the world of complex proteoforms, which are protein products with various primary structure alterations resulting from gene mutations, alternative splicing, post-translational modifications, and other biological processes. Proteoform identification is essential to mapping proteoforms to their biological functions as well as discovering novel proteoforms and new protein functions. Top-down mass spectrometry is the method of choice for identifying complex proteoforms because it provides a “bird’s eye view” of intact proteoforms. The combinatorial explosion of various alterations on a protein may result in billions of possible proteoforms, making proteoform identification a challenging computational problem. Results: We propose a new data structure, called the mass graph, for efficient representation of proteoforms and design mass graph alignment algorithms. We developed TopMG, a mass graph-based software tool for proteoform identification by top-down mass spectrometry. Experiments on top-down mass spectrometry data sets showed that TopMG outperformed existing methods in identifying complex proteoforms.

Dynamic Programming↗

Paddle-based rotating-shield brachytherapy

Purpose: The authors present a novel paddle-based rotating-shield brachytherapy (P-RSBT) method, whose radiation-attenuating shields are formed with a multileaf collimator (MLC), consisting of retractable paddles, to achieve intensity modulation in high-dose-rate brachytherapy. Methods: Five cervical cancer patients using an intrauterine tandem applicator were considered to assess the potential benefit of the P-RSBT method. The P-RSBT source used was a 50 kV electronic brachytherapy source (Xoft Axxent™). The paddles can be retracted independently to form multiple emission windows around the source for radiation delivery. The MLC was assumed to be rotatable. P-RSBT treatment plans were generated using the asymmetric dose–volume optimization with smoothness control method [Liu et al., Med. Phys. 41(11), 111709 (11pp.) (2014)] with a delivery time constraint, different paddle sizes, and different rotation strides. The number of treatment fractions (fx) was assumed to be five. As brachytherapy is delivered as a boost for cervical cancer, the dose distribution for each case includes the dose from external beam radiotherapy as well, which is 45 Gy in 25 fx. The high-risk clinical target volume (HR-CTV) doses were escalated until the minimum dose to the hottest 2 cm{sup 3} (D{sub 2cm{sup 3}}) of either the rectum, sigmoid colon, or bladder reached their tolerance doses of 75, 75, and 90 Gy{sub 3}, respectively, expressed as equivalent doses in 2 Gy fractions (EQD2 with α/β = 3 Gy). Results: P-RSBT outperformed the two other RSBT delivery techniques, single-shield RSBT (S-RSBT) and dynamic-shield RSBT (D-RSBT), with a properly selected paddle size. If the paddle size was angled at 60°, the average D{sub 90} increases for the delivery plans by P-RSBT on the five cases, compared to S-RSBT, were 2.2, 8.3, 12.6, 11.9, and 9.1 Gy{sub 10}, respectively, with delivery times of 10, 15, 20, 25, and 30 min/fx. The increases in HR-CTV D{sub 90}, compared to D-RSBT, were 16.6, 12.9, 7.2, 3.7, and 1.7 Gy{sub 10}, respectively. P-RSBT HR-CTV D{sub 90}-values were insensitive to the paddle size for paddles angled at less than 60°. Increasing the paddle angle from 5° to 60° resulted in only a 0.6 Gy{sub 10} decrease in HR-CTV D{sub 90} on average for five cases when the delivery times were set to 15 min/fx. The HR-CTV D{sub 90} decreased to 2.5 and 11.9 Gy{sub 10} with paddle angles of 90° and 120°, respectively. Conclusions: P-RSBT produces treatment plans that are dosimetrically and temporally superior to those of S-RSBT and D-RSBT, although P-RSBT systems may be more mechanically challenging to develop than S-RSBT or D-RSBT. A P-RSBT implementation with 4–6 shield paddles would be sufficient to outperform S-RSBT and D-RSBT if delivery times are constrained to less than 15 min/fx.

60 APPLIED LIFE SCIENCES↗

Polarization-dependent exciton dynamics in tetracene single crystals

We conduct polarization-dependent ultrafast spectroscopy to study the dynamics of singlet fission (SF) in tetracene single crystals. The spectrotemporal species for singlet and triplet excitons in transient absorption spectra are found to be strongly dependent on probe polarization. By carefully analyzing the polarization dependence, the signals contributed by different transitions related to singlet excitons have been disentangled, which is further applied to construct the correlation between dynamics of singlet and triplet excitons. The anisotropy of exciton dynamics provides an alternative approach to tackle the long-standing challenge in understanding the mechanism of singlet fission in organic semiconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Asymmetric dose–volume optimization with smoothness control for rotating-shield brachytherapy

Purpose: It is important to reduce fluence map complexity in rotating-shield brachytherapy (RSBT) inverse planning to improve delivery efficiency while maintaining plan quality. This study proposes an efficient and effective RSBT dose optimization method which enables to produce smooth fluence maps. Methods: Five cervical cancer patients each with a high-risk clinical-target-volume (HR-CTV) larger than 40 cm{sup 3} were considered as the test cases. The RSBT source was a partially shielded electronic brachytherapy source (Xoft Axxent™). The anchor RSBT plans generated by the asymmetric dose–volume optimization with smoothness control (ADOS) method were compared against those produced by the dose–surface optimization (DSO) method and inverse-planning with simulated annealing (IPSA). Either L{sub 1}-norm or L{sub 2}-norm was used to measure the smoothness of a fluence map in the proposed ADOS method as one weighted term of the objective function. Uniform dwell-time scaling was applied to all plans such that HR-CTV D{sub 90} was maximized without violating the D{sub 2cc} tolerances of the rectum, bladder, and sigmoid colon. The quality of the anchor plans was measured with HR-CTV D{sub 90} of the anchor plans. Single-shielded RSBT [(S-RSBT), RSBT with single, fix sized delivery window] and dynamic-sheilded RSBT [(D-RSBT), RSBT with dynamically varying sized delivery window] delivery plans generated based on the anchor plans were also measured, with delivery time constraints of 10, 20, and 30 min/fraction (fx). Results: The average HR-CTV D{sub 90} values of the anchor plans achieved by the ADOS, DSO, and IPSA methods were 111.5, 94.2, and 107.4 Gy, respectively, where the weighting parameter β used in ADOS with L{sub 2}-norm was set to be 100. By using S-RSBT sequencing and 20 min/fx delivery time, the corresponding D{sub 90} values were 88.8, 81.9, and 83.4 Gy; while using D-RSBT sequencing with 20 min/fx delivery time, the corresponding D{sub 90} values were 91.4, 88.3, and 78.9 Gy, respectively. The average optimization times for ADOS, DSO, and IPSA were, respectively, 77, 4, and 1800 s. By using L{sub 1}-norm instead of L{sub 2}-norm in the ADOS method, the optimization time was increased by 20 s, while the D{sub 90} was reduced by 6.8 Gy on average. ADOS-L1 was found to be more sensitive to the weighting parameter than ADOS-L2. If β was increased to 10 000, the D{sub 90} drop with ADOS-L1 was 38 Gy, while the drop with ADOS-L2 is 13 Gy. Conclusions: The ADOS method had a reasonable optimization time cost, while achieving comparable RSBT dose plans as the IPSA method, which is of much higher time complexity. Compared to the DSO and IPSA methods, ADOS is able to generate anchor plans which are more suitable for RSBT delivery while preserving the high quality of the original plans. Compared to ADOS-L1, ADOS-L2 is able to achieve better quality of anchor plans more efficiently.

60 APPLIED LIFE SCIENCES↗

Dynamic rotating-shield brachytherapy

Purpose: To present dynamic rotating shield brachytherapy (D-RSBT), a novel form of high-dose-rate brachytherapy (HDR-BT) with electronic brachytherapy source, where the radiation shield is capable of changing emission angles during the radiation delivery process.Methods: A D-RSBT system uses two layers of independently rotating tungsten alloy shields, each with a 180° azimuthal emission angle. The D-RSBT planning is separated into two stages: anchor plan optimization and optimal sequencing. In the anchor plan optimization, anchor plans are generated by maximizing the D{sub 90} for the high-risk clinical-tumor-volume (HR-CTV) assuming a fixed azimuthal emission angle of 11.25°. In the optimal sequencing, treatment plans that most closely approximate the anchor plans under the delivery-time constraint will be efficiently computed. Treatment plans for five cervical cancer patients were generated for D-RSBT, single-shield RSBT (S-RSBT), and {sup 192}Ir-based intracavitary brachytherapy with supplementary interstitial brachytherapy (IS + ICBT) assuming five treatment fractions. External beam radiotherapy doses of 45 Gy in 25 fractions of 1.8 Gy each were accounted for. The high-risk clinical target volume (HR-CTV) doses were escalated such that the D{sub 2cc} of the rectum, sigmoid colon, or bladder reached its tolerance equivalent dose in 2 Gy fractions (EQD2 with α/β= 3 Gy) of 75 Gy, 75 Gy, or 90 Gy, respectively.Results: For the patients considered, IS + ICBT had an average total dwell time of 5.7 minutes/fraction (min/fx) assuming a 10 Ci{sup 192}Ir source, and the average HR-CTV D{sub 90} was 78.9 Gy. In order to match the HR-CTV D{sub 90} of IS + ICBT, D-RSBT required an average of 10.1 min/fx more delivery time, and S-RSBT required 6.7 min/fx more. If an additional 20 min/fx of delivery time is allowed beyond that of the IS + ICBT case, D-RSBT and S-RSBT increased the HR-CTV D{sub 90} above IS + ICBT by an average of 16.3 Gy and 9.1 Gy, respectively.Conclusions: For cervical cancer patients, D-RSBT can boost HR-CTV D{sub 90} over IS + ICBT and S-RSBT without violating the tolerance doses to the bladder, rectum, or sigmoid. The D{sub 90} improvements from D-RSBT depend on the patient, the delivery time budget, and the applicator structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid emission angle selection for rotating-shield brachytherapy

Purpose: The authors present a rapid emission angle selection (REAS) method that enables the efficient selection of the azimuthal shield angle for rotating shield brachytherapy (RSBT). The REAS method produces a Pareto curve from which a potential RSBT user can select a treatment plan that balances the tradeoff between delivery time and tumor dose conformity. Methods: Two cervical cancer patients were considered as test cases for the REAS method. The RSBT source considered was a Xoft Axxent{sup TM} electronic brachytherapy source, partially shielded with 0.5 mm of tungsten, which traveled inside a tandem intrauterine applicator. Three anchor RSBT plans were generated for each case using dose-volume optimization, with azimuthal shield emission angles of 90 Degree-Sign , 180 Degree-Sign , and 270 Degree-Sign . The REAS method converts the anchor plans to treatment plans for all possible emission angles by combining neighboring beamlets to form beamlets for larger emission angles. Treatment plans based on exhaustive dose-volume optimization (ERVO) and exhaustive surface optimization (ERSO) were also generated for both cases. Uniform dwell-time scaling was applied to all plans such that that high-risk clinical target volume D{sub 90} was maximized without violating the D{sub 2cc} tolerances of the rectum, bladder, and sigmoid colon. Results: By choosing three azimuthal emission angles out of 32 potential angles, the REAS method performs about 10 times faster than the ERVO method. By setting D{sub 90} to 85-100 Gy{sub 10}, the delivery times used by REAS generated plans are 21.0% and 19.5% less than exhaustive surface optimized plans used by the two clinical cases. By setting the delivery time budget to 5-25 and 10-30 min/fx, respectively, for two the cases, the D{sub 90} contributions for REAS are improved by 5.8% and 5.1% compared to the ERSO plans. The ranges used in this comparison were selected in order to keep both D{sub 90} and the delivery time within acceptable limits. Conclusions: The REAS method enables efficient RSBT treatment planning and delivery and provides treatment plans with comparable quality to those generated by exhaustive replanning with dose-volume optimization.

60 APPLIED LIFE SCIENCES↗