Search NASA⌕ Search

Engineering topics

Liu, Yuxin

Publications and source records attributed to Liu, Yuxin.

Neuromorphic Photonics Based on Phase Change Materials

Neuromorphic photonics devices based on phase change materials (PCMs) and silicon photonics technology have emerged as promising solutions for addressing the limitations of traditional spiking neural networks in terms of scalability, response delay, and energy consumption. In this review, we provide a comprehensive analysis of various PCMs used in neuromorphic devices, comparing their optical properties and discussing their applications. We explore materials such as GST (Ge 2 Sb 2 Te 5 ), GeTe-Sb 2 Te 3 , GSST (Ge 2 Sb 2 Se 4 Te 1 ), Sb 2 S 3 /Sb 2 Se 3 , Sc 0.2 Sb 2 Te 3 (SST), and In 2 Se 3 , highlighting their advantages and challenges in terms of erasure power consumption, response rate, material lifetime, and on-chip insertion loss. By investigating the integration of different PCMs with silicon-based optoelectronics, this review aims to identify potential breakthroughs in computational performance and scalability of photonic spiking neural networks. Further research and development are essential to optimize these materials and overcome their limitations, paving the way for more efficient and high-performance photonic neuromorphic devices in artificial intelligence and high-performance computing applications.

36 MATERIALS SCIENCE↗

Intrinsically stretchable electrode array enabled in vivo electrophysiological mapping of atrial fibrillation at cellular resolution

Electrophysiological mapping of chronic atrial fibrillation (AF) at high throughput and high resolution is critical for understanding its underlying mechanism and guiding definitive treatment such as cardiac ablation, but current electrophysiological tools are limited by either low spatial resolution or electromechanical uncoupling of the beating heart. To overcome this limitation, here we introduce a scalable method for fabricating a tissue-like, high-density, fully elastic electrode (elastrode) array capable of achieving real-time, stable, cellular level-resolution electrophysiological mapping in vivo. Testing with acute rabbit and porcine models, the device is proven to have robust and intimate tissue coupling while maintaining its chemical, mechanical, and electrical properties during the cardiac cycle. The elastrode array records epicardial atrial signals with comparable efficacy to currently available endocardial-mapping techniques but with 2 times higher atrial-to-ventricular signal ratio and >100 times higher spatial resolution and can reliably identify electrical local heterogeneity within an area of simultaneously identified rotor-like electrical patterns in a porcine model of chronic AF.

60 APPLIED LIFE SCIENCES↗

Numerical Simulation of Residual Stresses in Multipass Gas Metal Arc-Welded Joints of Thick Aluminum Alloy Plates

Numerical simulation was utilized to investigate the residual stresses in the multipass gas metal arc-welded joints of high-strength Al-Zn-Mg alloy plates. In order to elevate the reliability of numerical simulation, the heat source model, parameters characterizing the thermal and mechanical properties, boundary conditions, material constitutive model and finite element meshing were discussed in detail. As a novelty of this paper, the modified Arrhenius constitutive equation of the base material and the filled material was obtained according to the results of high-temperature tensile tests. Distributions of stress on the upper and bottom surface of the joint were obtained based on numerical simulation. Special attention was paid to the evolutions of local residual stress on the bottom surface of the joint, and it’s found that residual stresses on the bottom surface of the joint were almost unchanged after the weld seam approached a certain thickness. Blind-hole method and x-ray method were adopted to detect the residual stresses on the surfaces to verify the accuracy of the results obtained by numerical simulation.

36 MATERIALS SCIENCE↗