Search NASA⌕ Search

Engineering topics

Liu, Z

Publications and source records attributed to Liu, Z.

At least 19 records

WE-FG-BRA-06: Systematic Study of Target Localization for Bioluminescence Tomography Guided Radiation Therapy for Preclinical Research

Purpose: To overcome the limitation of CT/CBCT in guiding radiation for soft tissue targets, we developed a bioluminescence tomography(BLT) system for preclinical radiation research. We systematically assessed the system performance in target localization and the ability of resolving two sources in simulations, phantom and in vivo environments. Methods: Multispectral images acquired in single projection were used for the BLT reconstruction. Simulation studies were conducted for single spherical source radius from 0.5 to 3 mm at depth of 3 to 12 mm. The same configuration was also applied for the double sources simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single source at 6 and 9 mm depth, 2 sources with 3 and 5 mm separation at depth of 5 mm or 3 sources in the abdomen were also used to illustrate the in vivo localization capability of the BLT system. Results: Simulation and phantom results illustrate that our BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single source case at 6 and 9 mm depth, respectively. For the 2 sources study, both sources can be distinguished at 3 and 5 mm separations at approximately 1 mm accuracy using 3D BLT but not 2D bioluminescence image. Conclusion: Our BLT/CBCT system can be potentially applied to localize and resolve targets at a wide range of target sizes, depths and separations. The information provided in this study can be instructive to devise margins for BLT-guided irradiation and suggests that the BLT could guide radiation for multiple targets, such as metastasis. Drs. John W. Wong and Iulian I. Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University.

60 APPLIED LIFE SCIENCES↗

Structural Deformation of Sm@C 88 under High Pressure

We have studied the structural transformation of Sm@C 88 under pressure up to 18 GPa by infrared spectroscopy combined with theoretical simulations. The infrared-active vibrational modes of Sm@C 88 at ambient conditions have been assigned for the first time. Pressure-induced blue and red shifts of the corresponding vibrational modes indicate an anisotropic deformation of the carbon cage upon compression. We propose that the carbon cage changes from ellipsoidal to approximately spherical around 7 GPa. A smaller deformation of the carbon bonds in the area close to the Sm atom in the cage suggests that the trapped Sm atom plays a role in minimizing the compression of the adjacent bonds. Pressure induced a significant reduction of the band gap of the crystal. The HOMO-LUMO gap of the Sm@C 88 molecule decreases remarkably at 7 GPa as the carbon cage is deformed. Also, compression enhances intermolecular interactions and causes a widening of the energy bands. Both effects decrease the band gap of the sample. The carbon cage deforms significantly above 7 GPa, from spherical to a peanut-like shape and collapses at 18 GPa.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Striving toward noble-metal-free photocatalytic water splitting: The hydrogenated-graphene-TiO 2 prototype

Graphane, graphone and hydrogenated graphene (HG) have been extensively studied in recent years due to their interesting properties and potential use in commercial and industrial applications. The present study reports investigation of hydrogenated graphene/TiO 2-x (HGT) nanocomposites as photocatalysts for H 2 and O 2 production from water without the assistance of a noble metal co-catalyst. By combination of several techniques, the morphologies, bulk/atomic structure and electronic properties of all the powders were exhaustively interrogated. Hydrogenation treatment efficiently reduces TiO 2 nanoparticles, while the graphene oxide sheets undergo the topotactic transformation from a graphene-like structure to a mixture of graphitic and turbostratic carbon (amorphous/disordered) upon altering the calcination atmosphere from a mildly reducing to a H 2 -abundant environment. Remarkably, the hydrogenated graphene-TiO 2-x composite that results upon H 2 -rich reduction exhibits the highest photocatalytic H 2 evolution performance equivalent to low loading of Pt (~0.12 wt%), whereas the addition of HG suppresses the O 2 production. As a result, we propose that such an enhancement can be attributed to a combination of factors including the introduction of oxygen vacancies and Ti 3+ states, retarding the recombination of charge carriers and thus, facilitating the charge transfer from TiO 2 -x to the carbonaceous sheet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-D-204-06: Dose and Image Quality Evaluation of a Low-Dose Slot-Scanning X-Ray System for Pediatric Orthopedic Studies

Purpose: Children in early teens with scoliosis require repeated radiographic exams over a number of years. The EOS (EOS imaging S.A., Paris, France) is a novel low-dose slot-scanning digital radiographic system designed to produce full-spine images of a free-standing patient. The radiation dose and image quality characteristics of the EOS were evaluated relative to those of a Computed Radiography (CR) system for scoliosis imaging. Methods: For dose evaluation, a full-torso anthropomorphic phantom was scanned five times using the default standard clinical protocols for both the EOS and a CR system, which include both posteroanterior and lateral full-spine views. Optically stimulated luminescent dosimeters (OSLDs), also known as nanoDots™ (Landauer, Inc., Glenwood, IL), were placed on the phantom’s surface to measure entrance skin dose. To assess image quality, MTF curves were generated from sampling the noise levels within the high-contrast regions of a line-pair phantom. Vertical and horizontal distortions were measured for the square line-pair phantom with the EOS system to evaluate the effects of geometric magnification and misalignment with the indicated imaging plane. Results: The entrance skin dose was measured to be 0.4 to 1.1 mGy for the EOS, and 0.7 to 3.6 mGy for the CR study. MTF comparison shows that CR greatly outperforms the EOS, despite both systems having a limiting resolution at 1.8 line-pairs per mm. Vertical distortion was unaffected by phantom positioning, because of the EOS slot-scanning geometry. Horizontal distortion increased linearly with miscentering distance. Conclusion: The EOS system resulted in approximately 70% lower radiation dose than CR for full-spine images. Image quality was found to be inferior to CR. Further investigation is required to see if EOS system is an acceptable modality for performing clinically diagnostic scoliosis examinations.

60 APPLIED LIFE SCIENCES↗

SU-E-J-244: Development and Validation of a Knowledge Based Planning Model for External Beam Radiation Therapy of Locally Advanced Non-Small Cell Lung Cancer

Purpose: The study aims to develop and validate a knowledge based planning (KBP) model for external beam radiation therapy of locally advanced non-small cell lung cancer (LA-NSCLC). Methods: RapidPlan™ technology was used to develop a lung KBP model. Plans from 65 patients with LA-NSCLC were used to train the model. 25 patients were treated with VMAT, and the other patients were treated with IMRT. Organs-at-risk (OARs) included right lung, left lung, heart, esophagus, and spinal cord. DVH and geometric distribution DVH were extracted from the treated plans. The model was trained using principal component analysis and step-wise multiple regression. Box plot and regression plot tools were used to identify geometric outliers and dosimetry outliers and help fine-tune the model. The validation was performed by (a) comparing predicted DVH boundaries to actual DVHs of 63 patients and (b) using an independent set of treatment planning data. Results: 63 out of 65 plans were included in the final KBP model with PTV volume ranging from 102.5cc to 1450.2cc. Total treatment dose prescription varied from 50Gy to 70Gy based on institutional guidelines. One patient was excluded due to geometric outlier where 2.18cc of spinal cord was included in PTV. The other patient was excluded due to dosimetric outlier where the dose sparing to spinal cord was heavily enforced in the clinical plan. Target volume, OAR volume, OAR overlap volume percentage to target, and OAR out-of-field volume were included in the trained model. Lungs and heart had two principal component scores of GEDVH, whereas spinal cord and esophagus had three in the final model. Predicted DVH band (mean ±1 standard deviation) represented 66.2±3.6% of all DVHs. Conclusion: A KBP model was developed and validated for radiotherapy of LA-NSCLC in a commercial treatment planning system. The clinical implementation may improve the consistency of IMRT/VMAT planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-332: Dosimetric Impact of Photon Energy and Treatment Technique When Knowledge Based Auto-Planning Is Implemented in Radiotherapy of Localized Prostate Cancer

Purpose: The aim of this study was to investigate the dosimetric impact of the combination of photon energy and treatment technique on radiotherapy of localized prostate cancer when knowledge based planning was used. Methods: A total of 16 patients with localized prostate cancer were retrospectively retrieved from database and used for this study. For each patient, four types of treatment plans with different combinations of photon energy (6X and 10X) and treatment techniques (7-field IMRT and 2-arc VMAT) were created using a prostate DVH estimation model in RapidPlan™ and Eclipse treatment planning system (Varian Medical System). For any beam arrangement, DVH objectives and weighting priorities were generated based on the geometric relationship between the OAR and PTV. Photon optimization algorithm was used for plan optimization and AAA algorithm was used for final dose calculation. Plans were evaluated in terms of the pre-defined dosimetric endpoints for PTV, rectum, bladder, penile bulb, and femur heads. A Student’s paired t-test was used for statistical analysis and p > 0.05 was considered statistically significant. Results: For PTV, V95 was statistically similar among all four types of plans, though the mean dose of 10X plans was higher than that of 6X plans. VMAT plans showed higher heterogeneity index than IMRT plans. No statistically significant difference in dosimetry metrics was observed for rectum, bladder, and penile bulb among plan types. For left and right femur, VMAT plans had a higher mean dose than IMRT plans regardless of photon energy, whereas the maximum dose was similar. Conclusion: Overall, the dosimetric endpoints were similar regardless of photon energy and treatment techniques when knowledge based auto planning was used. Given the similarity in dosimetry metrics of rectum, bladder, and penile bulb, the genitourinary and gastrointestinal toxicities should be comparable among the selections of photon energy and treatment techniques.

60 APPLIED LIFE SCIENCES↗

SU-E-T-786: Utility of Gold Wires to Optimize Intensity Modulation Capacity of a Novel Directional Modulated Brachytherapy Tandem Applicator for Image Guided Cervical Cancer Brachytherapy

Purpose: To evaluate the impact of using gold wires to differentially fill various channels on plan quality compared with conventional T&R applicator, inside a novel directional modulated brachytherapy (DMBT) tandem applicator for cervical cancer brachytherapy. Materials and Methods: The novel DMBT tandem applicator has a 5.4-mm diameter MR-compatible tungsten alloy enclosed in a 0.3-mm thick plastic tubing that wraps around the tandem. To modulate the radiation intensity, 6 symmetric peripheral holes of 1.3-mm diameter are grooved along the tungsten alloy rod. These grooved holes are differentially filled with gold wires to generate various degrees of directional beams. For example, three different fill patterns of 1) all void, 2) all filled except the hole containing the 192-Ir source, and 3) two adjacent holes to the 192-Ir source filled were Monte Carlo simulated. The resulting 3D dose distributions were imported into an in-house-coded inverse optimization planning system to generate HDR brachytherapy clinical plans for 19 patient cases. All plans generated were normalized to the same D90 as the clinical plans and D2cc doses of OARs were evaluated. Prescription ranged between 15 and 17.5Gy. Results: In general, the plans in case 1) resulted in the highest D2cc doses for the OARs with 11.65±2.30Gy, 7.47±3.05Gy, and 9.84±2.48Gy for bladder, rectum, and sigmoid, respectively, although the differences were small. For the case 2), D2cc doses were 11.61±2.29Gy, 7.41±3.07Gy, and 9.75±2.45Gy, respectively. And, for the case 3), D2cc doses were 11.60±2.28Gy, 7.41±3.05Gy, and 9.74±2.45Gy, respectively. Difference between 1) and 2) cases were small with the average D2cc difference of <0.64%. Difference between 1) and 3) cases were even smaller with the average D2cc difference of <0.1%. Conclusions: There is a minimal clinical benefit by differentially filling grooved holes in the novel DMBT tandem applicator for image guided cervical cancer brachytherapy.

60 APPLIED LIFE SCIENCES↗

TU-AB-201-01: A Comprehensive Planning Comparison Study Between a Novel Direction Modulated Brachytherapy Tandem Applicator and Conventional T&R Applicator for Image Guided Cervical Cancer Brachytherapy

Purpose: To demonstrate that utilization of a novel, intensity modulation capable, direction modulated brachytherapy (DMBT) tandem applicator can improve plan quality compared with conventional T&R applicator during an image guided cervical cancer brachytherapy. Methods: 45 cervical cancer patients treated with PDR brachytherapy were reviewed. Of them, a) 27 were treated using T&R only, b) 9 were treated using T&R with needles attached to the ring, and c) the remaining 9 were treated using T&R with needles attached to the ring (AN) as well as additional free-hand-loaded needles (FN). The DMBT tandem design has 6 peripheral holes of 1.3-mm diameter, grooved along a nonmagnetic tungsten alloy rod, enclosed in a plastic sheath with total 6.0-mm diameter. An in-house-coded inverse planning system was used for planning DMBT and T&R cases. All typical clinical constraints including OAR dose limits, dwell times, and loading patterns were respected. For the DMBT and T&R applicators, the plans were optimized with the same conventional ring in place, but repeatedly planned with and without AN/FN needles. All generated plans were normalized to the same D90 of the clinically treated plans. Results: For the plans in category a), DMBT generally outperformed T&R with average reduction in D2cc of −2.39%, −5.21%, and −2.69% for bladder, rectum, and sigmoid, respectively. For the plans in category b) and c), DMBT generally outperformed T&R if the same needles in AN/FN were utilized in both cases with average reduction in D2cc of −1.82%, −3.40%, and −6.04%, respectively. For the cases where the needles were not utilized for both applicators, an average D2cc reduction of −7.45%, −7.61%, and 17.47% were observed, respectively. Conclusions: Under the same clinical conditions, with/without needles, the DMBT applicator tends to generate more favorable plans compared with the conventional T&R applicator, and hence, is a promising technology.

60 APPLIED LIFE SCIENCES↗

Dry (Mg,Fe)SiO 3 perovskite in the Earth's lower mantle

Combined synthesis experiments and first-principles calculations show that MgSiO 3 -perovskite with minor Al or Fe does not incorporate significant OH under lower mantle conditions. Perovskite, stishovite, and residual melt were synthesized from natural Bamble enstatite samples (Mg/(Fe+Mg) = 0.89 and 0.93; Al 2 O 3 < 0.1 wt% with 35 and 2065 ppm wt H 2 O, respectively) in the laser-heated diamond anvil cell at 1600-2000 K and 25-65 GPa. Combined Fourier transform infrared (FTIR) spectroscopy, x-ray diffraction, and ex-situ transmission electron microscopy (TEM) analysis demonstrates little difference in the resulting perovskite as a function of initial water content. Four distinct OH vibrational stretching bands are evident upon cooling below 100 K (3576, 3378, 3274, and 3078 cm -1 ), suggesting 4 potential bonding sites for OH in perovskite with a maximum water content of 220 ppm wt H 2 O, and likely no more than 10 ppm wt H 2 O. Complementary, Fe-free, first-principles calculations predict multiple potential bonding sites for hydrogen in perovskite, each with significant solution enthalpy (0.2 eV/defect). We calculate that perovskite can dissolve less than 37 ppm wt H 2 O (400 ppm H/Si) at the top of the lower mantle, decreasing to 31 ppm wt H 2 O (340 ppm H/Si) at 125 GPa and 3000 K in the absence of a melt or fluid phase. Here, we propose that these results resolve a long-standing debate of the perovskite melting curve and explain the order of magnitude increase in viscosity from upper to lower mantle.

58 GEOSCIENCES↗