Single photon γ-ray imaging with high energy and spatial resolution perovskite semiconductor for nuclear medicine
Not provided.
Engineering topics
Publications and source records attributed to Liu, Zhifu.
Not provided.
High-flux capable semiconductor x-ray detectors are essential in various applications, but the detrimental effects of detector polarization limit their use in many cases. Here, for this work, we studied the polarization of perovskite CsPbBr 3 semiconductor detectors using ultrahigh flux synchrotron x rays (10 6 –10 12 photons s –1 mm –2 at 58.61 keV). The CsPbBr 3 detectors did not show immediate polarization prominently until a flux higher than 10 10 photons s –1 mm –2 . Using the pump-and-probe technique, we visualized the spatial and temporal effects of polarization. The polarized region, represented by reduced photocurrent, extended beyond the area under direct irradiation, and the reduced photocurrent persisted after potential de-polarization treatments. We found that stronger applied electric fields and fewer carrier traps can mitigate polarization, represented by less photocurrent deficit. By examining the detectors’ current response under controlled ambient light, low, and high-flux x rays, we studied the trap filling and release behavior of CsPbBr 3 . We discovered that the polarization is caused by partial detector damage due to deep defects generated by ultrahigh flux x-ray irradiation. Our work provides insight into CsPbBr 3 polarization under extremely intense x-ray radiation and shows that reducing crystal defects and increasing detector bias voltage are effective solutions.
Abstract Solution‐processed perovskites are promising for hard X‐ray and gamma‐ray detection, but there are limited reports on their performance under extremely intense X‐rays. Here, a solution‐grown all‐inorganic perovskite CsPbBr 3 single‐crystal semiconductor detector capable of operating at ultrahigh X‐ray flux of 10 10 photons s −1 mm −2 is reported. High‐quality solution‐grown CsPbBr 3 single crystals are fabricated into detectors with a Schottky diode structure of eutectic gallium indium/CsPbBr 3 /Au. A high reverse‐bias voltage of 1000 V (435 V mm − 1 ) can be applied with a small and stable dark current of ≈60–70 nA (≈9–10 nA mm − 2 ), which enables a high sensitivity larger than 10 000 µC Gy air −1 cm − 2 and a simultaneous low detection limit of 22 nGy air s − 1 . The CsPbBr 3 semiconductor detector shows an excellent photocurrent linearity and reproducibility under 58.61 keV synchrotron X‐rays with flux from 10 6 to 10 10 photons s − 1 mm − 2 . Defect characterization by thermally stimulated current spectroscopy shows a similar low defect density of a synchrotron X‐ray and a lab X‐ray irradiated device. Solid‐state nuclear magnetic resonance spectroscopy suggests that the excellent performance of the solution‐grown CsPbBr 3 single crystal may be associated with its good short‐range order, comparable to the spectrometer‐grade melt‐grown CsPbBr 3 .
Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .
Methods and devices for detecting incident radiation, such as incident X-rays, gamma-rays, and/or alpha particle radiation are provided. The methods and devices use high purity, high quality single-crystals of inorganic semiconductor compounds, including solid solutions, having the formula AB2X5, where A represents Tl or In, B represents Sn or Pb, and X represents Br or I, as photoelectric materials.
The detection of gamma-rays at room temperature with high-energy resolution using semiconductors is one of the most challenging applications. The presence of even the smallest amount of defects is sufficient to kill the signal generated from gamma-rays which makes the availability of semiconductors detectors a rarity. Lead halide perovskite semiconductors exhibit unusually high defect tolerance leading to outstanding and unique optoelectronic properties and are poised to strongly impact applications in photoelectric conversion/detection. Here we demonstrate for the first time that large size single crystals of the all-inorganic perovskite CsPbCl 3 semiconductor can function as a high-performance detector for gamma-ray nuclear radiation at room temperature. CsPbCl 3 is a wide-gap semiconductor with a bandgap of 3.03 eV and possesses a high effective atomic number of 69.8. We identified the two distinct phase transitions in CsPbCl 3 , from cubic (Pm-3m) to tetragonal (P4/mbm) at 325 K and finally to orthorhombic (Pbnm) at 316 K. Despite crystal twinning induced by phase transitions, CsPbCl 3 crystals in detector grade can be obtained with high electrical resistivity of similar to 1.7 X 10 9 Ω∙cm. The crystals were grown from the melt with volume over several cubic centimeters and have a low thermal conductivity of 0.6 W m -1 K -1 . The mobilities for electron and hole carriers were determined to similar to 30 cm 2 /(V s). Using photoemission yield spectroscopy in air (PYSA), we determined the valence band maximum at 5.66 +/- 0.05 eV. Under gamma-ray exposure, our Schottky-type planar CsPbCl 3 detector achieved an excellent energy resolution (similar to 16% at 122 keV) accompanied by a high figure-of-merit hole mobility-lifetime product (3.2 x 10 -4 cm 2 /V) and a long hole lifetime (16 mu s). The results demonstrate considerable defect tolerance of CsPbCl 3 and suggest its strong potential for gamma-radiation and X-ray detection at room temperature and above.
Room temperature semiconductor detector (RTSD) materials for γ-ray and X-ray radiation are in great demand for the nonproliferation of nuclear materials as well as for biomedical imaging applications. Halide perovskites have attracted great attention as emerging and promising RTSD materials. In this contribution, the material synthesis, purification, crystal growth, crystal structure, photoluminescence properties, ionizing radiation detection performance, and electronic structure of the inorganic halide perovskitoid compound TlPbI 3 are reported on. This compound crystallizes in the ABX 3 non-perovskite crystal structure with a high density of d = 6.488 g·cm –3 , has a wide bandgap of 2.25 eV, and melts congruently at a low temperature of 360 °C without phase transitions, which allows for facile growth of high quality crystals with few thermally-activated defects. High-quality TlPbI 3 single crystals of centimeter-size are grown using the vertical Bridgman method using purified raw materials. A high electrical resistivity of ≈10 12 Ω·cm is readily obtainable, and detectors made of TlPbI 3 single crystals are highly photoresponsive to Ag K α X-rays (22.4 keV), and detects 122 keV γ-rays from 57 Co radiation source. The electron mobility-lifetime product µ e τ e was estimated at 1.8 × 10 –5 cm 2 ·V –1 . A high relative static dielectric constant of 35.0 indicates strong capability in screening carrier scattering and charged defects in TlPbI 3 .
Halide perovskite semiconductors are poised to revitalize the field of ionizing radiation detection as they have done to solar photovoltaics. We show that all-inorganic perovskite CsPbBr 3 devices resolve 137 Cs 662-keV γ-rays with 1.4% energy resolution, as well as other X- and γ-rays with energies ranging from tens of keV to over 1 MeV in ambipolar sensing and unipolar hole-only sensing modes with crystal volumes of 6.65 mm 3 and 297 mm 3 , respectively. Furthermore, we report the scale-up of CsPbBr 3 ingots to up to 1.5 inches in diameter with an excellent hole mobility–lifetime product of 8 × 10 -3 cm 2 V -1 and a long hole lifetime of up to 296 μs. CsPbBr 3 detectors demonstrate a wide temperature region from ~2 °C to ~70 °C for stable operation. Detectors protected with suitable encapsulants show a uniform response for over 18 months. Consequently, we identify perovskite CsPbBr 3 semiconductor as an exceptional candidate for new-generation high-energy γ-ray detection.
Highly efficient neutron detectors are critical in many sectors, including national security, medicine, crystallography and astronomy. The main neutron detection technologies currently used involve 3 He-gas-filled proportional counters and light scintillators for thermalized neutrons. Semiconductors could provide the next generation of neutron detectors because their advantages could make them competitive with or superior to existing detectors. In particular, solids with a high concentration of high-neutron-capture nuclides (such as 6 Li, 10 B) could be used to develop smaller detectors with high intrinsic efficiencies. However, no promising materials have been reported so far for the construction of direct-conversion semiconductor detectors. Here we report on the semiconductor LiInP 2 Se 6 and demonstrate its potential as a candidate material for the direct detection of thermal neutrons at room temperature. This compound has a good thermal-neutron-capture cross-section, a suitable bandgap (2.06 electronvolts) and a favourable electronic band structure for efficient electron charge transport. We used α particles from an 241 Am source as a proxy for the neutron-capture reaction and determined that the compact two-dimensional (2D) LiInP 2 Se 6 detectors resolved the full-energy peak with an energy resolution of 13.9 per cent. Direct neutron detection from a moderated Pu–Be source was achieved using 6 Li-enriched (95 per cent) LiInP 2 Se 6 detectors with full-peak resolution. Here, we anticipate that these results will spark interest in this field and enable the replacement of 3 He counters by semiconductor-based neutron detectors.