Search NASA⌕ Search

Engineering topics

Liyanage, Nilanga

Publications and source records attributed to Liyanage, Nilanga.

μRWELL detector developments at Jefferson Lab for high luminosity experiments

One of the future plans at Jefferson Lab is running electron scattering experiments with large acceptance detectors at luminosities > 10^37 cm^−2 s^−1. These experiments allow the measurements of the Double Deeply Virtual Compton Scattering (DDVCS) reaction, an important physics process in the formalism of Generalized Parton Distributions, which has never been measured because of its small cross-section. The luminosity upgrade of CLAS12 or the SOLID detector makes Jefferson Lab a unique place to measure DDVCS. One of the important components of these high luminosity detectors is a tracking system that can withstand high rates of ≈ 1MHz/cm2. The recently developed Micro-Resistive Well (𝜇RWELL) detector technology is a promising option for such a tracking detector by combining good position resolutions, low material budget with simple mechanical construction, and low production costs. In this proceeding, we will discuss recent developments and studies with 𝜇RWELL detectors at Jefferson Lab for future upgrades of the CLAS12 detector to study the DDVCS reaction.

Hauenstein, Florian↗

Elastic positron–proton scattering at low Q$^2$

Systematic differences in the the proton's charge radius, as determined by ordinary atoms and muonic atoms, have caused a resurgence of interest in elastic lepton scattering measurements. The proton's charge radius, defined as the slope of the charge form factor at Q$^2$=0, does not depend on the probe. Any difference in the apparent size of the proton, when determined from ordinary versus muonic hydrogen, could point to new physics or need for the higher order corrections. While recent measurements seem to now be in agreement, there is to date no high precision elastic scattering data with both electrons and positrons. A high precision proton radius measurement could be performed in Hall B at Jefferson Lab with a positron beam and the calorimeter based setup of the PRad experiment. This measurement could also be extended to deuterons where a similar discrepancy has been observed between the muonic and electronic determination of deuteron charge radius. A new, high precision measurement with positrons, when viewed alongside electron scattering measurements and the forthcoming MUSE muon scattering measurement, could help provide new insights into the origins of the proton radius puzzle, and also provide new experimental constraints on radiative correction calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Generalized Spin Polarizabilities of the Neutron in the Low-Q{sup 2} Region

Understanding the nucleon spin structure in the regime where the strong interaction becomes truly strong poses a challenge to both experiment and theory. At energy scales below the nucleon mass of about 1 GeV, the intense interaction among the quarks and gluons inside the nucleon makes them highly correlated. Their coherent behaviour causes the emergence of effective degrees of freedom, requiring the application of non-perturbative techniques such as chiral effective field theory1. Here we present measurements of the neutron’s generalized spin polarizabilities that quantify the neutron’s spin precession under electromagnetic fields at very low energy-momentum transfer squared down to 0.035 GeV2. In this regime, chiral effective field theory calculations2–4 are expected to be applicable. Our data, however, show a strong discrepancy with these predictions, presenting a challenge to the current description of the neutron’s spin properties.

Sulkosky, Vincent↗

Advanced extraction of the deuteron charge radius from electron-deuteron scattering data

To extract the charge radius of the proton, $r_{p}$, from the electron scattering data, the PRad collaboration at Jefferson Lab has developed a rigorous framework for finding the best functional forms - the fitters - for a robust extraction of $r_{p}$ from a wide variety of sample functions for the range and uncertainties of the PRad data. In this work we utilize and further develop this framework. Herein we discuss methods for searching for the best fitter candidates as well as a procedure for testing the robustness of extraction of the deuteron charge radius, $r_{d}$, from parameterizations based on elastic electron-deuteron scattering data. The ansatz proposed in this paper for the robust extraction of $r_{d}$, for the proposed low-$Q^{2}$ DRad experiment at Jefferson Lab, can be further improved once there are more data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust extraction of the proton charge radius from electron-proton scattering data

Background: Extracting the proton charge radius from electron scattering data requires determining the slope of the charge form factor at Q 2 15 of zero. But as experimental data never reach that limit, numerous methods for making the extraction have been proposed, though often the functions are determined after seeing the data which can lead to confirmation bias. Purpose: To find functional forms that will allow for a robust extraction of the input radius for a wide variety of functional forms in order to have confidence in the extraction from upcoming low Q 2 experimental data such as the Jefferson Lab PRad experiment. Method: We create a general framework for inputting form-factor functions as well as various fitting functions. The input form factors are used to generate pseudo-data with fluctuations intended to mimic the binning and random uncertainty of a given set of real data. All combinations of input functions and fit functions can then be tested repeatedly against regenerated pseudo-data. Since the input radius is known, this allows us to find those functions that are robust for radius extractions in an objective fashion. Results: For the range and uncertainty of the PRad data, we find that a two-parameter rational function, a two-parameter continued fraction and the second order polynomial expansion of z can extract the input radius regardless of the input charge form factor function that is used. Conclusions: We have created an easily expandable framework to search for functional forms that allow for a robust extraction of the radius from a given binning and uncertainty of pseudo-data generated from a wide variety of trial functions. This method has enabled a successful search for the best functional forms to extract the radius from the upcoming PRad data, and can be used for other experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large size GEM for Super Bigbite Spectrometer (SBS) polarimeter for Hall A 12GeV program at JLab

We report on the R&D effort in the design and construction of a large size GEM chamber for the Proton Polarimeter of the Super Bigbite Spectrometer (SBS) in Hall A at Thomas Jefferson National Laboratory (JLab). The SBS Polarimeter trackers consist of two sets of four large chambers of size 200 cm x 60 cm 2 . Each chamber is a vertical stack of four GEM modules with an active area of 60 cm x 50 cm. We have built and tested several GEM modules and we describe in this paper the design and construction of the final GEM as well as the preliminary results on performances from tests carried out in our detector lab and with test beams at (Fermilab).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision Measurement of the Neutron Twist-3 Matrix Element dn2: Probing Color Forces

Double-spin asymmetries and absolute cross sections were measured at large Bjorken x (0.25 lte x lte 0.90), in both the deep-inelastic and resonance regions, by scattering longitudinally polarized electrons at beam energies of 4.7 and 5.9 GeV from a transversely and longitudinally polarized 3He target. In this dedicated experiment, the spin structure function g2 on 3He was determined with precision at large x, and the neutron twist-three matrix element dn2 was measured at ?Q2? of 3.21 and 4.32 GeV2/c2, with an absolute precision of about 10?5. Our results are found to be in agreement with lattice QCD calculations and resolve the disagreement found with previous data at ?Q2?= 5 GeV2/c2. Combining dn2 and a newly extracted twist-four matrix element, fn2, the average neutron color electric and magnetic forces were extracted and found to be of opposite sign and about 60 MeV/fm in magnitude.

Posik, Matthew↗

FLYSUB-Consortium Tracking and RICH Performance Evaluation

This is a technical scope of work (TSW) between the Fermi National Accelerator Laboratory (Fermilab) and the experiments of FLYSUB-Consortium who have committed to participate in beam tests to be carried out during the 2013-2014 Fermilab Test Beam Facility program. The ultimate goal of this test-beam effort is to test and verify the performance of the individual components according to their expectation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗