Search NASA⌕ Search

Engineering topics

Liyi Gu

Publications and source records attributed to Liyi Gu.

Planning In-Flight Calibration for XRISM

The XRISM X-ray observatory will fly two advanced instruments, the Resolve high-resolution spectrometer and the Xtend wide-field imager. These instruments, particularly Resolve, pose calibration challenges due to the unprecedented combination of spectral resolution, spectral coverage, and effective area, combined with a need to characterize the imaging fidelity of the full instrument system to realize the mission’s ambitious science goals. We present the status of the XRISM in-flight calibration plan, building on lessons from Hitomi and other X-ray missions. We present a discussion of targets and observing strategies to address the needed calibration measurements, with a focus on developing methodologies to plan a thorough and flexible calibration campaign and provide insight on calibration systematic error. We also discuss observations that exploit Resolve’s spectral resolution to calibrate atomic codes, and cross-calibration between the XRISM instruments and with other observatories.

Eric D Miller↗

X-ray Spectra of the Fe-L Complex II: Atomic Data Constraints from the EBIT Experiment and X-Ray Grating Observations of Capella

The Hitomi results for the Perseus cluster have shown that accurate atomic models are essential to the success of X-ray spectroscopic missions and just as important as the store of knowledge on instrumental calibration and astrophysical modeling. Preparing the models requires a multifaceted approach, including theoretical calculations, laboratory measurements, and calibration using real observations. In a previous paper, we presented a calculation of the electron impact cross sections on the transitions forming the Fe-L complex. In the present work, we systematically tested the calculation against cross-sections of ions measured in an electron beam ion trap experiment. A two-dimensional analysis in the electron beam energies and X-ray photon energies was utilized to disentangle radiative channels following dielectronic recombination, direct electron-impact excitation, and resonant excitation processes in the experimental data. The data calibrated through laboratory measurements were further fed into a global modeling of the Chandra grating spectrum of Capella. We investigated and compared the fit quality, as well as the sensitivity of the derived physical parameters to the underlying atomic data and the astrophysical plasma modeling. We further list the potential areas of disagreement between the observations and the present calculations, which, in turn, calls for renewed efforts with regard to theoretical calculations and targeted laboratory measurements.

Liyi Gu↗

Roadmap on cosmic EUV and x-ray spectroscopy

Cosmic EUV/x-ray spectroscopists, including both solar and astrophysical analysts, have a wide range of high-resolution and high-sensitivity tools in use and a number of new facilities in development for launch. As this bandpass requires placing the spectrometer beyond the Earth’s atmosphere, each mission represents a major investment by a national space agency such as NASA, ESA, or JAXA, and more typically a collaboration between two or three. In general justifying new mission requires an improvement in capabilities of at least an order of magnitude, but the sensitivity of these existing missions are already taxing existing atomic data quantity and accuracy. This roadmap reviews the existing missions, showing how in a number of areas atomic data limits the science that can be performed. The missions that will be launched in the coming Decade will without doubt require both more and improved measurements of wavelengths and rates, along with theoretical calculations of collisional and radiative cross sections for a wide range of processes.

Randall Smith↗

An X-Ray Spectroscopic Search For Dark Matter And Unidentified Line Signatures In The Perseus Cluster With Hitomi

The reported detection of a 3.5 keV emission signal in the Perseus cluster core by Bulbulet al. (2014, ApJ, 789, 13) was ruled out at high confidence in analysis conducted by Aharonian et al. (2017, ApJ, 837, L15) of X-ray spectra at 5 eV energy resolution obtained with the Hitomi observatory Soft X-ray Spectrometer (SXS). Using the same data, we search the full 2–12 keV SXS energy band for previously unidentified emission and absorption features. No significant unidentified line emission or absorption is found. Line flux upper limits (1σper resolution element) vary with photon energy and assumed intrinsic width, decreasing from∼100 at 2 keV to<10 photons cm−2s−1sr−1over most of the 5–10 keV energy range for a Gaussian line with Doppler broadening of 640 kms−1. Limits for narrower and broader lines have a similar energy dependence and are systematically smaller and larger, respectively. These line flux limits are used to constrain the decay rate of hypothetical dark matter candidates. For the sterile neutrino decay rate, we place new constraints over the mass range of 4–24 keV with mass resolution better than any previous X-ray analysis. Additionally, the accuracy of relevant thermal spectral models and atomic data are evaluated. The Perseus cluster spectra may be described by a composite of multi-temperature thermal and active galactic nuclei (AGN) power-law continua. Superposed on these, a few line emission signals possibly originating from unmodeled atomic processes (including SiXIV and FeXXV)are marginally detected and tabulated. Comparisons with previous X-ray upper limits and future prospects for dark matter searches using high-energy resolution spectroscopy are discussed.

Takayuki Tamura↗