Search NASA⌕ Search

Engineering topics

Logan, Bruce E.

Publications and source records attributed to Logan, Bruce E..

Hydrogen production in microbial electrolysis cells with biocathodes

Electroautotrophic microbes at biocathodes in microbial electrolysis cells (MECs) can catalyze the hydrogen evolution reaction with low energy demand, facilitating long-term stable performance through specific and renewable biocatalysts. However, MECs have not yet reached commercialization due to a lack of understanding of the optimal microbial strains and reactor configurations for achieving high performance. Here, we critically analyze the criteria for the inocula selection, with a focus on the effect of hydrogenase activity and microbe–electrode interactions. We also evaluate the impact of the reactor design and key parameters, such as membrane type, composition, and electrode surface area on internal resistance, mass transport, and pH imbalances within MECs. Furthermore, this analysis paves the way for advancements that could propel biocathode-assisted MECs toward scalable hydrogen gas production.

Biotechnology & Applied Microbiology↗

Hydrocarbon-based membranes cost-effectively manage species transport and increase performance in thermally regenerative batteries

Low-temperature heat (T<130°C) can be utilized by thermally regenerative batteries (TRBs) for power production, allowing the thermal energy to be converted to storable chemical potential energy. However, TRBs suffer from high ohmic losses and ammonia crossover, which has slowed their development. In this study, we examined how the use of six different membranes influenced TRB performance, determined the most influential membrane parameters, and identified promising membrane candidates that cost-effectively increase TRB performance. Of the six membranes examined, an inexpensive, hydrocarbon CEM (Selemion CMVN) had low ammonia crossover without compromising resistance, resulting in good performance across all metrics studied. A thin anion exchange membrane (Sustainion, 50 microns) showed a high peak power density of 82 mW cm –2 due to low resistance, but the average power density and energy density were low due to high ammonia flux. Full discharge curves using Selemion CMVN provided an average power density of 26 ± 7 mW cm –2 with an energy density of 2.9 Wh L –1 , which were large improvements on previous TRBs. A techno-economic analysis showed that Selemion CMVN had the lowest levelized cost of storage ($410 per MWh) at an applied current density of 50 mA cm –2 .

25 ENERGY STORAGE↗

Increasing the Electrolyte Salinity to Improve the Performance of Anion Exchange Membrane Water Electrolyzers

Direct operation of anion exchange membrane water electrolyzers (AEMWEs) with near-neutral pH feeds avoids the use of highly alkaline and corrosive solutions. However, using neutral pH solutions currently faces fundamental operational challenges that diminish performance and reduce long-term stability due to poor solution conductivity and low hydroxide ion concentration. Here, we showed that amending near-neutral pH solutions with low concentrations of alkali metal salts in a dry-cathode configuration substantially improved performance and stability. Adding NaClO 4 (10 mM) to the anolyte reduced the operating voltage by 0.19 to 2.58 V at 500 mA/cm 2 compared to non-saline solutions (2.77 V). However, further increases in the feed salt concentration (100 mM NaClO 4 ) reduced performance (2.64 V) due to a greater co-ion diffusion through the anion exchange membrane. Electrolyzer performance was further improved by utilizing salts with high conductivity such as KNO 3 . Using a saline anolyte reduced ohmic resistance, resulting in smaller applied voltage and energy consumption for hydrogen generation, while the combined effect of the membrane charge and the electric field direction in the dry-cathode feed configuration minimized ion crossover. Thus, increasing the salinity of near-neutral pH solutions represents a cost-effective strategy to improve the performance of AEMWE compared to ultrapure electrolytes, minimizing risks and costs associated with recirculating highly alkaline solutions.

anion exchange membrane water electrolyzer↗

System efficiency and power assessment of the all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) use low-temperature (T < 100 °C) heat to provide stationary energy and power with higher power densities and efficiency relative to other waste heat devices. TRABs are an active area of research in waste heat devices, but currently there is little consensus on what aspect of the system is limiting TRAB performance and what maximum efficiencies are possible. Experiments and numerical models were used here to examine the sensitivity of the battery and distillation column in a TRAB system to key operating variables, thereby establishing practical limits and identifying focus areas for improving performance. Battery power was eight times more sensitive to ohmic losses than kinetic and mass transfer losses, regardless of the operating temperature, and the peak power density was simulated to be 18.8 mW cm –2 at 75 °C. Theoretical energy efficiency limits were defined for a series of ammonia concentrations and operating pressures, ranging from 5 – 12%, which is 2–3 times higher than previous experimental estimations. Atmospheric pressure column operation used a larger amount of waste heat compared to sub-atmospheric pressure. It is estimated that the volume of the battery would take up 9.2m 3 for every 1% of the power output of a natural gas turbine, but with realistic improvements to cell conductivity, the size would reduce to 2.5 m 3 . Finally, the results presented in this work will help streamline future development by focusing on minimizing ohmic losses and provide specific data for full system evaluation of future TRABs.

25 ENERGY STORAGE↗

Using nickel-molybdenum cathode catalysts for efficient hydrogen gas production in microbial electrolysis cells

A low-cost cathode catalyst based on a NiMo alloy was examined here to replace noble metals for the hydrogen production in microbial electrolysis cells (MECs). Two NiMo catalysts were synthesized through either an electrochemical assisted (NiMo Elec) or a hydrothermal (NiMo Ht) approach. The NiMo Ht method enriched the electrocatalyst with Mo atoms compared to the NiMo Elec approach, producing a similar current density with a minimal overpotential of 50mV compared to Pt. Further, in MEC tests using the NiMo Ht catalyst, H 2 was generated at a highest rate of 81±3 L H2 /L-d (current density of 44.4 ± 0.9 A/m 2 ) at a cell voltage of -0.86 V, and a Coulombic efficiency of >97%. Modifying the closely stacked MEC design to include a reference electrode, and analysis of the electrode potentials using the electrode potential slope method, revealed a large contribution of the cathode resistance (5.3±0.5mΩm 2 ) compared to the anode (1.4±0.2mΩm 2 ) and ohmic resistance (0.83mΩm 2 ) for a total internal resistance of 7.6±0.5mΩm 2 . The high performance of the NiMo Ht catalyst coupled with its low cost provides an economically viable approach to advance the generation of biohydrogen in MECs.

25 ENERGY STORAGE↗

Power and energy capacity tradeoffs in an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) can provide energy storage and produce electrical power from low-grade waste heat instead of electricity. The use of all-aqueous copper-based electrolytes has recently produced higher power densities than those achieved using previous TRAB approaches based on reversible metal deposition and dissolution processes, but further gains are possible in power and energy density. We investigated the limitations of power and energy density and how they are impacted by the electrolyte composition and discharge currents. By increasing the ammonia concentration from 1 to 5 M, the power density of the battery increased from 11.2 to 28.5 mW cm –2 , but the energy density decreased from 0.56 to 0.31 Wh L –1 . Increasing discharge current densities from 4 to 12.5 mA cm –2 increased the average power density during discharge from 2.4 to 5.9 mW cm –2 without appreciable losses in energy density. Increasing the copper concentration from 0.1 to 0.5 M increased both energy density to 2.15 Wh L –1 and energy efficiency to 2.2% but did not substantially impact the power density. Furthermore, these results represent the highest performance metrics achieved for a low-grade waste heat to electricity system.

25 ENERGY STORAGE↗

Vapor-Fed Cathode Microbial Electrolysis Cells with Closely Spaced Electrodes Enables Greatly Improved Performance

Hydrogen can be electrochemically produced in microbial electrolysis cells (MECs) by current generated from bacterial anodes with a small added voltage. MECs typically use a liquid catholyte containing a buffer or salts. However, anions in these catholytes result in charge being balanced predominantly by ions other than hydroxide or protons, leading to anode acidification. To enhance only hydroxide ion transport to the anode, we developed a novel vapor-fed MEC configuration lacking a catholyte with closely spaced electrodes and an anion exchange membrane to limit the acidification. This MEC design produced a record-high sustained current density of 43.1 ± 0.6 A/m 2 and a H 2 production rate of 72 ± 2 LH 2 /L-d (cell voltage of 0.79 ± 0.00 V). There was minimal impact on MEC performance of increased acetate concentrations, solution conductivity, or anolyte buffer capacity at applied voltages up to 1.1 V, as shown by a nearly constant internal resistance of only 6.8 ± 0.3 mΩ m 2 . At applied external voltages >1.1 V, the buffer capacity impacted performance, with current densities increasing from 28.5 ± 0.6 A/m 2 (20 mM phosphate buffer solution (PBS)) to 51 ± 1 A/m 2 (100 mM PBS). Furthermore, these results show that a vapor-fed MEC can produce higher and more stable performance than liquid-fed cathodes by enhancing transport of hydroxide ions to the anode.

anion exchange membrane↗