Search NASA⌕ Search

Engineering topics

Logan, Pamela

Publications and source records attributed to Logan, Pamela.

Further Studies Of Hot-Wire Anemometry

Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Represents extension of work described in "Hot-Wire Anemometry Versus Laser-Induced Fluorescence" (ARC-11802). Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF).

Mckenzie, Robert↗

Accuracy Of Hot-Wire Anemometry In Supersonic Turbulence

Sensitivity of hot-wire probe compared to laser-induced-florescence measurements. Report discusses factors affecting readings of hot-wire anemometer in turbulent supersonic boundary layer. Presents theoretical analysis of responses of hot-wire probe to changes in flow; also compares measurements by hot-wire probe with measurements of same flows by laser-induced fluorescence (LIF). Because LIF provides spatially and temporally resolved data on temperature, density, and pressure, provides independent means to determine responses of hot-wire anemometers to these quantities.

Logan, Pamela↗

Improved method of analyzing hot-wire measurements in supersonic turbulence

The present analysis method for hot-wire data in supersonic turbulence takes sound field effects into account and yields greater accuracy in its treatment of flow variable fluctuations than existing methods despite requiring only a moderately accurate estimate of static pressure fluctuations. The method demonstrates the way in which neglecting pressure fluctuations will affect hot-wire data analysis, as well as indicating the probable direction the errors will take.

Logan, Pamela↗

Hot-wire accuracy in supersonic turbulence from comparisons with laser-induced fluorescence

A hot-wire anemometer and a new, nonintrusive, laser-induced fluorescence (LIF) technique are used to survey a turbulent boundary layer in a supersonic channel flow at Mach no. 2.06. The purpose is to test the accuracy of using the hot wire to measure the fluctuation amplitudes of static temperature and density in a compressible turbulent flow by comparing the results with independent and direct LIF measurements. Several methods of hot-wire calibration and analysis are applied. With each method, the hot-wire response can be related primarily to fluctuations of mass flux and total temperature, from which fluctuations of static temperature and density are calculated. However, these calculations are shown to be valid only if the fluctuations in static pressure are negligible. The acquisition and the analysis of the hot-wire data are often simplified further by neglecting the effects of fluctuations in total temperature. Comparisons of the fluctuation amplitudes of temperature and density obtained by hot-wire and LIF measurements demonstrate that such assumptions might not always be warranted, even in apparently simple flows.

Logan, Pamela↗

Measuring Gases With Laser-Induced Fluorescence

Temperature, density, and pressure at selected point in low-temperature, turbulent gaseous flow measured simultaneously by pulsed laser-induced fluorescence (LIF). Measurements made with spatial and temporal resolution. LIF measurements nonintrusive and constitute first alternative means of measuring turbulent fluctuations in temperature and density that compares with conventional hot-wire-anemometer data. Laser beams focused to small spots in wind tunnel and reference cell induce fluorescence in nitric oxide, small amount s mixed with main gas flow. Fluorescence radiation depends on main-gas temperature, pressure, and density and measured to deduce these quantities.

Mckenzie, Robert L.↗