Search NASA⌕ Search

Engineering topics

Lord, Neal

Publications and source records attributed to Lord, Neal.

Seismic Survey 2016 Data at Crescent Valley, Nevada

In September 2016, 989 vertical-component seismic instruments were deployed for 75 hours at the Crescent Valley greenfield geothermal play area in Nevada. Data were recorded 12/9/16 - 12/15/16. Data are stored in individual files in one-minute increments in SEGD formats. See the metadata in Crescent Valley Station Locations.sp1, Crescent Valley Observer Logs.xls, and the attached Metadata link for details about the seismic station locations, seismic data logger specifications, instrumentation specifications, descriptions of data, a fracture finding summary, and the final report for the 2016 seismic survey done in Crescent Valley, Nevada. Note that no discrete events were identified, and a 1750m x 2250m x 300m PSET volume of acoustic energy was delivered.

15 GEOTHERMAL ENERGY↗

Enhanced Microseismicity During Production Pumping Cessation at the San Emidio Geothermal Field (Nevada, USA) in December 2016

Abstract Tectonic activity, geothermal fluids, and microseismic events (MSEs) tend to occur in similar locations as a result of spatiotemporal changes in the subsurface stress state. To quantify this association, we analyze data from a dense seismic array deployed at the San Emidio geothermal field, Nevada for 1 week in December 2016 to coincide with a 19.45‐hr shutdown of all injection and production pumping operations. 123 MSEs were detected, of which 101 occurred during the shutdown. The spatial association of the MSEs with the production wells suggests a causal relationship between the production cessation and the MSEs. Here we performed a detailed analysis to investigate reservoir material properties, distribution of seismically activated faults, and local stress state. We determined the hypocenters, magnitudes, and focal mechanisms for the MSEs, P‐wave tomographic velocity model, and local stress tensor. The results show that most MSEs occurred near the production wells. Magnitudes fall between −2.2 and 0.0 with larger events located closer to the production wells. Most MSEs occurred within a westward‐dipping normal fault zone in the reservoir associated with anomalously low P‐wave velocity values. The focal mechanism and stress inversion results show predominantly normal faulting with the maximum horizontal stress oriented north‐south. We suggest that the MSEs during shutdown were triggered on pre‐existing, small‐scale, critically stressed fault patches in the reservoir as the pore pressure increased around the production wells when the production pumping ceased. We interpret the larger MSE magnitudes closer to the production wells as a result of higher pore pressure increase.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Seismic Survey Data from San Emidio Nevada 2021

This dataset includes raw and processed seismic data from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 N, 119.409019 W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended at 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The dataset is hosted in an AWS data lake, with an associated GDR data set providing the metadata. Links to both of these resources are included below. Additionally, this collection features data and metadata from a 2016 seismic survey at the same site for comparative analysis.

15 GEOTHERMAL ENERGY↗

WHOLESCALE: Seismic Survey Metadata from San Emidio Nevada 2021

This is a collection of metadata from the 2021 seismic survey at the San Emidio geothermal field in Nevada. In April and May 2021, 37 tri-axial short period seismographs were deployed in a 1.8km diameter cluster centered on 40.367278 deg N, 119.409019 deg W. The first data record started at 2021-04-06T07:09:10Z UTC and the last record ended 2021-05-11T02:58:52Z UTC. The 37 stations included 29 SmartSolo IGU-16HR 3C all-in-one 5 Hz seismographs and 8 DataCube seismographs with 4.5 Hz HGS HG-6(B coil) tri-axial geophones. The raw format (level 0) data includes 353 GB of 500 sps SmartSolo data in native DLD format, 113 GB of 400 sps DataCube data in native DataCube format, and 3.4 GB of GPS data collected during the RTK GPS survey. The SAC data (level 1) files include 564 GB of hourly SAC files. The experiment was designed to monitor seismic activity before, during, and after the planned three-day plant maintenance shutdown April 19-21, 2021. The pumping stopped at 2021/04/19 12:51:45 UTC and resumed about 2021/04/21 21:00:00 UTC. The raw and processed data are in an associated GDR submission, linked below. The metadata here includes files containing experiment details, station locations, seismic data logger specifications, instrumentation specifications, and descriptions of data. Also included are data and metadata from a 2016 seismic survey at the same site.

15 GEOTHERMAL ENERGY↗