Losey, R.

Publications and source records attributed to Losey, R..

Testing of three hot- air solar collectors

Report presents procedures used and results obtained during program to determine pressure drops across three prototype hot-air solar collectors as function of air velocity and operating temperature.

Losey, R.↗

Indoor and outdoor tests of a liquid solar collector

Two reports describe thermal-performance data obtained on double-covered liquid solar collector. One report describes data obtained during outdoor testing and the other describes indoor test data obtained by using Marshall Space Flight Center solar simulator. Indoor data were taken to verify performance of solar simulator.

Losey, R.↗

Performance evaluation of two black nickel and two black chrome solar collectors

The test program was based on the evaluation of four unique solar collectors described below: (1) black nickel collector surface with a desiccant drying bed, (2) black nickel collector surface without a desiccant drying bed, (3) black chrome collector surface with a dessicant drying bed, and (4) black chrome collector surface without a desiccant drying bed. The test program included three distinct phases: Initial performance evaluation, natural environmental aging, and post-aging performance evaluation. Results of Phase III testing conclusively indicated a higher normalized efficiency for Black Chrome surfaces when compared to Black Nickel.

Losey, R.↗

MSFC hot air collectors. Phase 1: Test report

A development test program of 3 hot air flat plate solar collectors is described in detail. The pressure drop versus flow rate performance characteristics for these collectors, mounted in series, was determined under 14 different test conditions each of which was characterized by a unique combination of inlet air temperature and air flow rate. Characteristics of inlet, exit and transfer ducts of these collectors were also determined during this testing. The test results indicate that significant pressure drop occurs at air flow rates greater than 150 standard cubic feet per minute and this drop is not heavily dependent upon inlet air temperature; and inlet, exit and transfer duct characteristics differ sufficiently to suggest that system performance may be enhanced through careful design of each type of duct individually.

Losey, R.↗

Thermal performance of honeywell double covered liquid solar collector

The test procedures and results obtained during an evaluation test program to determine the outdoor performance characteristics of the Honeywell liquid solar collector are presented. The program was based on the thermal evaluation of a Honeywell double covered liquid solar collection. Initial plans included the simultaneous testing of a single covered Honeywell collector. During the initial testing, the single covered collector failed due to leakage; thus, testing continued on the double covered collector only. To better define the operating characteristics of the collector, several additional data points were obtained beyond those requested.

Losey, R.↗