Search NASASearch

Engineering topics

Love, A. W.

Publications and source records attributed to Love, A. W..

Null-balancing microwave radiometer

Device performs absolute temperature measurements over range of 0 to 300 degrees Kelvin. Stability of device approaches 0.1 degrees Kelvin. Potential uses include detecting oil slicks on water and determining cloud water content and water vapor content of atmosphere.

Hardy, W. N.

Temperature reference for microwave radiometer calibration

New temperature reference avoids need to physically remove antenna and replace it with calibrating termination. Device is piece of porous microwave absorber fitted with cap of nonporous plastic foam. Absorbent material is soaked with cryogen. Procedure ensures that temperature at which microwaves are absorbed is exactly that of cryogen.

Love, A. W.

Study of shuttle imaging microwave system antenna. Volume 1: Conceptual design

A detailed preliminary design and complete performance evaluation are presented of an 11-channel large aperture scanning radiometer antenna for the shuttle imaging microwave system (SIMS) program. Provisions for interfacing the antenna with the space shuttle orbiter are presented and discussed. A program plan for hardware development and a rough order of magnitude (ROM) cost are also included. The conceptual design of the antenna is presented. It consists of a four-meter diameter parabolic torus main reflector, which is a graphite/epoxy shell supported by a graphite/epoxy truss. A rotating feed wheel assembly supports six Gregorian subreflectors covering the upper eight frequency channels from 6.6 GHz through 118.7 GHz, and two three-channel prime forms feed assemblies for 0.6, 1.4, and 2.7 GHz. The feed wheel assembly also holds the radiometers and power supplies, and a drive system using a 400 Hz synchronous motor is described. The RF analysis of the antenna is performed using physical optics procedures for both the dual reflector Gregorian concept and the single reflector prime focus concept. A unique aberration correcting feed for 2.7 GHz is analyzed. A structural analysis is also included. The analyses indicate that the antenna will meet system requirements.

Wesley, R. W.

Nondestructive measurement of capillary tube internal diameter

Technique provides nondestructive method of making quick, accurate determination by measuring electrical resistance of capillary tube when it is filled with electrolyte of known conductivity. Apparatus consists of conductivity cell and equipment for measuring resistance and for monitoring and controlling temperature.

Ho, W. W.

A survey of ATL-compatible radiometer antennas

A survey was made of antennas suitable for remote sensing of the earth's surface, in particular the world ocean, by means of microwave radiometers operating in the 1 to 26 GHz frequency region and carried on board the shuttle-launched advanced technology laboratory. Array antennas are found to be unattractive and unsuited to the task. Reflectors, including Cassegrain and offset types, as well as horn-reflectors are possible candidates but all have shortcomings which impair the accuracy of measurement. Horns of the corrugated type have excellent electrical characteristics. Although they are physically very large and will require development of suitable deployment mechanisms, they appear to be valid candidates for the task. The evolution of the periscope antenna is outlined, and it is shown to possess nearly ideal electrical characteristics for the intended application. Its only shortcoming is that the feed horn creates aperture blocking; there is no blocking due to struts or any other source. The periscope antenna is recommended for ATL radiometry.

Love, A. W.

Measurements of the dielectric properties of sea water at 1.43 GHz

Salinity and temperature of water surfaces of estuaries and bay regions are determined to accuracies of 1 ppt salinity and 0.3 kelvin surface temperature. L-band and S-band radiometers are used in combination as brightness temperature detectors. The determination of the brightness temperature versus salinity, with the water surface temperature as a parameter for 1.4 GHz, is performed with a capillary tube inserted into a resonance cavity. Detailed analysis of the results indicates that the measured values are accurate to better than 0.2 percent in the electric property epsilon' and 0.4 percent in epsilon''. The calculated brightness temperature as a function of temperature and salinity is better than 0.2 kelvin. Thus it is possible to reduce the measured data obtained with the two-frequency radiometer system with 1 ppt accuracy to values in the salinity range 5 to 40 ppt.

Ho, W. W.

An S-band radiometer design with high absolute precision

A radiometer for the remote measurement of sea surface temperature is described. The development of an instrument capable not only of high relative accuracy (i.e., resolution) but also of high absolute precision is considered. The concepts underlying the design of an instrument capable of an absolute accuracy of a few tenths degrees Kelvin in the measurement of brightness temperature at S band are described. The role of the antenna is discussed, and the importance of high ohmic and beam efficiencies is stressed. The hardware itself is fully described, along with an outline concerning the design of a unique cryogenically cooled termination used to calibrate the whole radiometer, including antenna. Finally, some test results are presented that show that the design goals for the instrument have been closely approached.

Hardy, W. N.

Development of a satellite microwave radiometer to sense the surface temperature of the world oceans

A proposed S-band radiometer for determining the ocean surface temperature with an absolute accuracy of + or - 1 Kelvin and a resolution of + or - .1 Kelvin was placed under the Advanced Applications Flight Experiment for further development into Nimbus readiness state. The results of assessing the following are described: effects due to the state of the sea surface, effects caused by the intervening atmosphere, and effects associated with imperfections in the instrument itself. An extensive sea truth program is also described for correlation of aircraft test flight measurements or of satellite remote measurement to in-situ data. An improved radiometer design is a modified Dicke-switch type with temperature stabilized, microwave integrated circuit, front-end and with a pulsed injection-noise nulling system. The radiometer has a multimode rectangular horn antenna with very low ohmic losses and a beam efficiency of 98% or better.

Hidy, G. M.

Microwave measurement of thermal emission from the sea.

Review of the results of some experimental and theoretical investigations of various limiting factors in microwave measurements of thermal emission from the sea, ranging from instrumentation to surface properties of the ocean. It is shown that absolute measurement of the thermal emission from the sea can be made at 2.69 GHz, with accuracies of better than plus or minus 1 K within the present state of microwave instrument development. The principal uncertainties on interpretation of such observations in terms of molecular temperature of the sea involve: (1) surface contamination such as oil slicks, (2) spray and foaming, (3) salinity variation, and (4) surface waves.

Gray, K. W.