Search NASA⌕ Search

Engineering topics

Lu, Ning

Publications and source records attributed to Lu, Ning.

105 records · Page 6

Unit Commitment Considering Generation Flexibility and Environmental Constraints

This paper proposes a new framework for power system unit commitment process, which incorporates the generation flexibility requirements and environmental constraints into the existing unit commitment algorithm. The generation flexibility requirements are to address the uncertainties with large amount of intermittent resources as well as with load and traditional generators, which causes real-time balancing requirements to be variable and less predictable. The proposed flexibility requirements include capacity, ramp and ramp duration for both upward and downward balancing reserves. The environmental constraints include emission allowance for fossil fuel-based generators and ecological regulations for hydro power plants. Calculation of emission rates is formulated. Unit commitment under this new framework will be critical to the economic and reliable operation of the power grid and the minimization of its negative environmental impacts, especially when high penetration levels of intermittent resources are being approached, as required by the renewable portfolio standards in many states.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Evaluation of the Flywheel Potential for Providing Regulation Service in California

Flywheels can provide regulation and frequency response services to the power grids. This study presents the technical characteristics, modeling approach, methodologies, and results for providing regulation services in the California Independent System Operator (CAISO) market. Breakeven cost analyses were developed for two cases: 1) flywheel provides the regulation service alone; and 2) flywheel provides the regulation service together with a hydro power plant. For both cases, we evaluated two payment methods: pay-by-energy and pay-by-capacity. Based on the results of the technical and cost analyses, the opportunities for the flywheel providing regulation services are discussed; field test results for the flywheel’s physical characteristics are presented; and performance metrics of the flywheel to provide the regulation services are suggested.

25 ENERGY STORAGE↗

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid

Abstract—This paper presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover, the peak load months will spread out to not only the summer months but also spring and autumn months. The Pacific Northwest will experience more hot days in the summer months. The penetration of the air conditioning (a/c) system in this area is likely to increase significantly over the years. As a result, some locations in the Pacific Northwest may be shifted from winter peaking to summer peaking. Overall, the Western U.S. grid may see more simultaneous peaks across the North and South in summer months. Increased cooling load will result in a significant increase in the motor load, which consumes more reactive power and requires stronger voltage support from the grid. This study suggests an increasing need for the industry to implement new technology to increase the efficiency of temperature-sensitive loads and apply proper protection and control to prevent possible adverse impacts of a/c motor loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart-Grid Security Issues

TITLE: Smart-Grid Security Issues (Editorial Material, English) IEEE SECURITY & PRIVACY 8 (1). JAN-FEB 2010. p.81-85 IEEE COMPUTER SOC, LOS ALAMITOS

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid FriendlyTM Device Model Development and Simulation

In late 2007, the Bonneville Power Administration (BPA) contracted Pacific Northwest National Laboratory (PNNL) to complete a research project titled Grid-Responsive Demand-Side Control Using Grid Friendly Appliance Technologies [Hammerstrom 2009, DeSteese and Hammerstrom 2009]. Cosponsors included Portland General Electric (PGE) and Puget Sound Energy (PSE). The project focused on applications of the Grid Friendly Appliance (GFA) controller, which is an autonomous controller that was designed to advise devices like appliances concerning valuable demand-side grid services that should be conducted. The controller bases its advice on observations it makes from the ac voltage signal. Electric tank water heaters were selected to be controlled by the GFA controller in this project. Two autonomous responses are addressed herein. First, an under-voltage-responsive water heater is able to recognize sudden reductions in feeder circuit voltage at each water heater and may curtail any electric load that is being consumed by the water heater. These under-voltage events are usually induced by nearby electrical faults. An under-voltage response is necessarily specified by the set of voltage thresholds at which the responsive water heaters would respond. The set of voltages at which the curtailment would be released must also be specified. Additionally, any delays prior to the water heater load becoming curtailed or again released must be specified. For example, a delay may be intentionally imposed prior to curtailing water heater loads to avoid responses during the fault itself. Much longer and randomized delays should be imposed prior to the release of curtailments in order to re-establish diversity of the water heater loads and soften what could otherwise be an abrupt reintroduction of a large aggregated electrical load into the already stressed grid region.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing a Collaborative Visual Analytics Tool for Social and Technological Change Prediction.

We describe our ongoing efforts to design and develop a collaborative visual analytics tool to interactively model social and technological change of our society in a future setting. The work involves an interdisciplinary team of scientists from atmospheric physics, electrical engineering, building engineering, social sciences, economics, public policy, and national security. The goal of the collaborative tool is to predict the impact of global climate change on the U.S. power grids and its implications for society and national security. These future scenarios provide critical assessment and information necessary for policymakers and stakeholders to help formulate a coherent, unified strategy toward shaping a safe and secure society. The paper introduces the problem background and related work, explains the motivation and rationale behind our design approach, presents our collaborative visual analytics tool and usage examples, and finally shares the development challenge and lessons learned from our investigation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Generator Bidding Strategies in a Competitive Electricity Market with Derating and Bid-Segment Considerations

This paper develops optimal generator bidding strategies in a competitive electricity market. Starting from a generator’s cost curve, basic bidding concepts such as the break-even bid curve and the maximum profit bid curve can be readily derived. The maximum profit bid curve can be extended to account for generator availability and derating. In addition, multiple-segment block energy bids can be optimized based on the maximum profit curve and the probabilistic distribution of market clearing prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Temperature Sensitivity of the Residential Load and Commercial Building Load

This paper presents a building modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building heating and cooling load in 10 major cities across the Western United States and Canada. A building simulation software are first used to quantify the hourly energy consumption of different building types by end-use and by vintage. Then, the temperature sensitivities are derived based on the climate data inputs.

climate change, temperature sensitivity, load mode↗

The System Impact of Air-Conditioner Under-voltage Protection Schemes

This paper presents simulation results of evaluating an under-voltage protection scheme designed to take stalled air-conditioner (a/c) units offline such that the slow voltage recovery phenomena can be solved on areas heavily loaded with a/c motors during summer peak periods. A three feeder test-bed has been first used to quantify the effectiveness of the protection scheme and the sensitivity of the under-voltage relay settings. Then two real system events of the Western US power grid have been studied to evaluate the area impact of the protection scheme proposed by Southern California Edison. The study demonstrates that by taking all or most of the stalled a/c unit offline, the feeder voltage will recover in a few seconds, much quicker than the tens of seconds that the standard thermal relays imbedded in the motors need to trip the units. The drawback of the control scheme is that after the voltage recover, it settled at a higher voltage than before the faults because a large chuck of load has been shed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Predicting the Impact of Climate Change on U.S. Power Grids and Its Wider Implications on National Security

We discuss our technosocial analytics research and devel-opment on predicting and assessing the impact of climate change on U.S. power-grids and the wider implications for national security. The ongoing efforts extend cutting-edge modeling theories derived from climate, energy, social sciences, and national security domains to form a unified system coupled with an interactive visual interface for technosocial analysis. The goal of the system is to create viable future scenarios that address both technical and social factors involved in the model domains. These scenarios enable policy makers to formulate a coherent, unified strategy towards building a safe and secure society. The paper gives an executive summary of our efforts in the past fiscal year and provides a glimpse of our work planned for the second year of the three-year project being conducted at the Pacific Northwest National Laboratory.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid

This report presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover, the peak load months will spread out to not only the summer months but also spring and autumn months. The Pacific Northwest will experience more hot days in the summer months. The penetration of the air conditioning (a/c) system in this area is likely to increase significantly over the years. As a result, some locations in the Pacific Northwest may be shifted from winter peaking to summer peaking. Overall, the Western U.S. grid may see more simultaneous peaks across the North and South in summer months. Increased cooling load will result in a significant increase in the motor load, which consumes more reactive power and requires stronger voltage support from the grid. This study suggests an increasing need for the industry to implement new technology to increase the efficiency of temperature-sensitive loads and apply proper protection and control to prevent possible adverse impacts of a/c motor loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Conditioner Compressor Performance Model

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A grid quality manipulation system

A grid quality manipulation system is described. The elements of the system are the measures by which quality is assessed, the computer graphic display of those measures, and the local grid manipulation to provide a response to the viewed quality indication. The display is an overlaid composite where the region is first covered with colors to reflect the values of the quality indicator, the grid is then placed on top of those colors, and finally a control net is placed on top of everything. The net represents the grid in terms of the control point form of algebraic grid generation. As a control point is moved, both the grid and the colored quality measures also move. This is a real time dynamic action so that the consequences of the manipulation are continuously seen.

Lu, Ning↗