Search NASA⌕ Search

Engineering topics

Lu, W

Publications and source records attributed to Lu, W.

At least 55 records · Page 3

SU-E-T-08: A Convolution Model for Head Scatter Fluence in the Intensity Modulated Field

Purpose: To efficiently calculate the head scatter fluence for an arbitrary intensity-modulated field with any source distribution using the source occlusion model. Method: The source occlusion model with focal and extra focal radiation (Jaffray et al, 1993) can be used to account for LINAC head scatter. In the model, the fluence map of any field shape at any point can be calculated via integration of the source distribution within the visible range, as confined by each segment, using the detector eye's view. A 2D integration would be required for each segment and each fluence plane point, which is time-consuming, as an intensity-modulated field contains typically tens to hundreds of segments. In this work, we prove that the superposition of the segmental integrations is equivalent to a simple convolution regardless of what the source distribution is. In fact, for each point, the detector eye's view of the field shape can be represented as a function with the origin defined at the point's pinhole reflection through the center of the collimator plane. We were thus able to reduce hundreds of source plane integration to one convolution. We calculated the fluence map for various 3D and IMRT beams and various extra-focal source distributions using both the segmental integration approach and the convolution approach and compared the computation time and fluence map results of both approaches. Results: The fluence maps calculated using the convolution approach were the same as those calculated using the segmental approach, except for rounding errors (<0.1%). While it took considerably longer time to calculate all segmental integrations, the fluence map calculation using the convolution approach took only ∼1/3 of the time for typical IMRT fields with ∼100 segments. Conclusions: The convolution approach for head scatter fluence calculation is fast and accurate and can be used to enhance the online process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-475: An Accurate Linear Model of Tomotherapy MLC-Detector System for Patient Specific Delivery QA

Purpose: An accurate leaf fluence model can be used in applications such as patient specific delivery QA and in-vivo dosimetry for TomoTherapy systems. It is known that the total fluence is not a linear combination of individual leaf fluence due to leakage-transmission, tongue-and-groove, and source occlusion effect. Here we propose a method to model the nonlinear effects as linear terms thus making the MLC-detector system a linear system. Methods: A leaf pattern basis (LPB) consisting of no-leaf-open, single-leaf-open, double-leaf-open and triple-leaf-open patterns are chosen to represent linear and major nonlinear effects of leaf fluence as a linear system. An arbitrary leaf pattern can be expressed as (or decomposed to) a linear combination of the LPB either pulse by pulse or weighted by dwelling time. The exit detector responses to the LPB are obtained by processing returned detector signals resulting from the predefined leaf patterns for each jaw setting. Through forward transformation, detector signal can be predicted given a delivery plan. An equivalent leaf open time (LOT) sinogram containing output variation information can also be inversely calculated from the measured detector signals. Twelve patient plans were delivered in air. The equivalent LOT sinograms were compared with their planned sinograms. Results: The whole calibration process was done in 20 minutes. For two randomly generated leaf patterns, 98.5% of the active channels showed differences within 0.5% of the local maximum between the predicted and measured signals. Averaged over the twelve plans, 90% of LOT errors were within +/−10 ms. The LOT systematic error increases and shows an oscillating pattern when LOT is shorter than 50 ms. Conclusion: The LPB method models the MLC-detector response accurately, which improves patient specific delivery QA and in-vivo dosimetry for TomoTherapy systems. It is sensitive enough to detect systematic LOT errors as small as 10 ms.

60 APPLIED LIFE SCIENCES↗

High transformer ratio drive beams for wakefield accelerator studies

For wakefield based acceleration schemes, use of an asymmetric (or linearly ramped) drive bunch current profile has been predicted to enhance the transformer ratio and generate large accelerating wakes. We discuss plans and initial results for producing such bunches using the 20 to 23 GeV electron beam at the FACET facility at SLAC National Accelerator Laboratory and sending them through plasmas and dielectric tubes to generate transformer ratios greater than 2 (the limit for symmetric bunches). The scheme proposed utilizes the final FACET chicane compressor and transverse collimation to shape the longitudinal phase space of the beam.

43 PARTICLE ACCELERATORS↗

Head erosion with emittance growth in PWFA

Head erosion is one of the limiting factors in plasma wakefield acceleration (PWFA). We present a study of head erosion with emittance growth in field-ionized plasma from the PWFA experiments performed at the FACET user facility at SLAC. At FACET, a 20.3 GeV bunch with 1.8 Multiplication-Sign 10{sup 10} electrons is optimized in beam transverse size and combined with a high density lithium plasma for beam-driven plasma wakefield acceleration experiments. A target foil is inserted upstream of the plasma source to increase the bunch emittance through multiple scattering. Its effect on beamplasma interaction is observed with an energy spectrometer after a vertical bend magnet. Results from the first experiments show that increasing the emittance has suppressed vapor field-ionization and plasma wakefields excitation. Plans for the future are presented.

43 PARTICLE ACCELERATORS↗

Coherent transition radiation from a self-modulated charged particle beam

Plasma wakefield accelerator utilizing a TeV proton beam is a promising method to generate a TeV electron beam. However the length of the existing proton beam is too long compared with the proper plasma skin depth. As a result selfmodulation instability takes place after such a long pulse enters into the plasma. The transverse spot size of the long beam changes periodically in the longitudinal direction. Therefor measurement of the coherent transition radiation when the selfmodulated beam leaves the plasma is a possible method to demonstrate the self-modulation instability. In this paper, we analyze the angular spectrum of this coherent transition radiation when the beam comes from plasma to vacuum.

43 PARTICLE ACCELERATORS↗

Ultra-bright XUV emission from laser wakefields in underdense plasma

By use of particle-in-cell (PIC) simulation, we observe ultra-bright XUV radiation pulses emerging from a laser wakefield driven above the wave-breaking threshold in underdense plasma, which is as short as a few hundred attoseconds in one-dimentsional simulations and a few femtoseconds in two-dimensional simulations. It is concerned with the formation of a transverse narrow current layer co-moving with the intense laser pulse. This current layer is formed by an electron density spike with trapped electrons in the wakefield with certain transverse kinetic momentum of electrons left behind the laser pulse. This net momentum appears when the driving laser pulse undergoes strong selfmodulation and subsequent pulse steepening at the front. In the multi-dimensional simulations, the XUV emission is found only near the laser axis with a much smaller spot size than the laser pulse due to the transverse dynamics of the trapped electrons. The present scheme provides an alternative method to produce ultra-bright XUV pulses for ultrafast applications.

07 ISOTOPE AND RADIATION SOURCES↗

Scaling of the Longitudinal Electric Field and Transformer Ratio in a Nonlinear Plasma Wakefield Accelerator

The scaling of the two important figures of merit, the transformer ratio T and the longitudinal electric field E{sub z}, with the peak drive-bunch current I{sub p}, in a nonlinear plasma wakefield accelerator is presented for the first time. The longitudinal field scales as I{sub P}{sup 0.623{+-}0.007}, in good agreement with nonlinear wakefield theory ({approx}I{sub P}{sup 0.5}), while the unloaded transformer ratio is shown to be greater than unity and scales weakly with the bunch current. The effect of bunch head erosion on both parameters is also discussed.

43 PARTICLE ACCELERATORS↗

Performance and operation of advanced superconducting electron cyclotron resonance ion source SECRAL at 24 GHz

SECRAL (superconducting ECR ion source with advanced design in Lanzhou) ion source has been in routine operation for Heavy Ion Research Facility in Lanzhou (HIRFL) accelerator complex since May 2007. To further enhance the SECRAL performance in order to satisfy the increasing demand for intensive highly charged ion beams, 3-5 kW high power 24 GHz single frequency and 24 GHz +18 GHz double frequency with an aluminum plasma chamber were tested, and some exciting results were produced with quite a few new record highly charged ion beam intensities, such as {sup 129}Xe{sup 35+} of 64 e{mu}A, {sup 129}Xe{sup 42+} of 3 e{mu}A, {sup 209}Bi{sup 41+} of 50 e{mu}A, {sup 209}Bi{sup 50+} of 4.3 e{mu}A and {sup 209}Bi{sup 54+} of 0.2 e{mu}A. In most cases SECRAL is operated at 18 GHz to deliver highly charged heavy ion beams for the HIRFL accelerator, only for those very high charge states and very heavy ion beams such as {sup 209}Bi{sup 36+} and {sup 209}Bi{sup 41+}, SECRAL has been operated at 24 GHz. The total operation beam time provided by SECRAL up to July 2011 has exceeded 7720 hours. In this paper, the latest performance, development, and operation status of SECRAL ion source are presented. The latest results and reliable long-term operation for the HIRFL accelerator have demonstrated that SECRAL performance for production of highly charged heavy ion beams remains improving at higher RF power with optimized tuning.

43 PARTICLE ACCELERATORS↗

Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics

A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

43 PARTICLE ACCELERATORS↗

Study of ion beam transport from the SECRAL electron cyclotron resonance ion source at the Institute of Modern Physics

Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

43 PARTICLE ACCELERATORS↗

Synchrotron X-ray Study of Filled Skutterudites CeFe4Sb12 and Ce0.8Fe3CoSb12

In situ synchrotron X-ray diffraction measurements are carried out on filled skutterudites CeFe{sub 4}Sb{sub 12} and Ce{sub 0.8}Fe{sub 3}CoSb{sub 12} up to 32 and 20 GPa, respectively, at room temperature. No phase transformation was observed for both samples in the pressure range. Fitting the pressure-volume data (up to 10 GPa) to the third-order Birch-Murnaghan equation of state, the bulk modulus B{sub 0} is determined to be 74(4) GPa, with the pressure derivative B'{sub 0} = 7(2) for CeFe{sub 4}Sb{sub 12}, and B{sub 0} = 71(2) GPa and B'{sub 0} = 8(2) for Ce{sub 0.8}Fe{sub 3}CoSb{sub 12}. The bulk moduli of filled skutterudites CeFe{sub 4}Sb{sub 12} and Ce{sub 0.8}Fe{sub 3}CoSb{sub 12} in our study are smaller than those from previous studies on unfilled skutterudite CoSb{sub 3}. The P-V curves of the unfilled skutterudite CoSb{sub 3} and filled skutterudites CeyFe{sub 4-x}Co{sub x}Sb{sub 12} showed good agreement, indicating that the Ce filling fraction and the replacement of Fe with Co have little effect on their compression behaviors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable Multiple Layered Dirac Cones in Optical Lattices

We show that multiple layered Dirac cones can emerge in the band structure of properly addressed multicomponent cold fermionic gases in optical lattices. The layered Dirac cones contain multiple copies of massless spin-1/2 Dirac fermions at the same location in momentum space, whose different Fermi velocity can be tuned at will. On-site microwave Raman transitions can further be used to mix the different Dirac species, resulting in either splitting of or preserving the Dirac point (depending on the symmetry of the on-site term). The tunability of the multiple layered Dirac cones allows us to simulate a number of fundamental phenomena in modern physics, such as neutrino oscillations and exotic particle dispersions with E{approx}p{sup N} for arbitrary integer N.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results from Plasma Wakefield Experiments at FACET

We report initial results of the Plasma Wakefield Acceleration (PWFA) Experiments performed at FACET - Facility for Advanced aCcelertor Experimental Tests at SLAC National Accelerator Laboratory. At FACET a 23 GeV electron beam with 1.8 x 10{sup 10} electrons is compressed to 20 {mu}m longitudinally and focused down to 10 {mu}m x 10 {mu}m transverse spot size for user driven experiments. Construction of the FACET facility completed in May 2011 with a first run of user assisted commissioning throughout the summer. The first PWFA experiments will use single electron bunches combined with a high density lithium plasma to produce accelerating gradients > 10 GeV/m benchmarking the FACET beam and the newly installed experimental hardware. Future plans for further study of plasma wakefield acceleration will be reviewed. The experimental hardware and operation of the plasma heat-pipe oven have been successfully commissioned. Plasma wakefield acceleration was not observed because the electron bunch density was insufficient to ionize the lithium vapor. The remaining commissioning time in summer 2011 will be dedicated to delivering the FACET design parameters for the experimental programs which will begin in early 2012. PWFA experiments require the shorter bunches and smaller transverse sizes to create the plasma and drive large amplitude wakefields. Low emittance and high energy will minimize head erosion which was found to be a limiting factor in acceleration distance and energy gain. We will run the PWFA experiments with the design single bunch conditions in early 2012. Future PWFA experiments at FACET are discussed in [5][6] and include drive and witness bunch production for high energy beam manipulation, ramped bunch to optimize tranformer ratio, field-ionized cesium plasma, preionized plasmas, positron acceleration, etc.. We will install a notch collimator for two-bunch operation as well as new beam diagnostics such as the X-band TCAV [7] to resolve the two bunches. With these new instruments and desired beam parameters in place next year, we will be able to complete the studies of plasma wakefield acceleration in the next few years.

43 PARTICLE ACCELERATORS↗

Halo Formation And Emittance Growth of Positron Beams in Plasmas

An ultrarelativistic 28.5 GeV, 700-{micro}m-long positron bunch is focused near the entrance of a 1.4-m-long plasma with a density n{sub e} between {approx}10{sup 13} and {approx}5 x 10{sup 14} cm{sup -3}. Partial neutralization of the bunch space charge by the mobile plasma electrons results in a reduction in transverse size by a factor of {approx}3 in the high emittance plane of the beam {approx}1 m downstream from the plasma exit. As n{sub e} increases, the formation of a beam halo containing {approx}40% of the total charge is observed, indicating that the plasma focusing force is nonlinear. Numerical simulations confirm these observations. The bunch with an incoming transverse size ratio of {approx}3 and emittance ratio of {approx}5 suffers emittance growth and exits the plasma with approximately equal sizes and emittances.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dirac-Weyl fermions with arbitrary spin in two-dimensional optical superlattices

Dirac-Weyl fermions are massless relativistic particles with a well-defined helicity which arise in the context of high-energy physics. Here we propose a quantum simulation of these paradigmatic fermions using multicomponent ultracold atoms in a two-dimensional square optical lattice. We find that laser-assisted spin-dependent hopping, specifically tuned to the (2s+1)-dimensional representations of the su(2) Lie algebra, directly leads to a regime where the emerging massless excitations correspond to Dirac-Weyl fermions with arbitrary pseudospin s. We show that this platform hosts two different phases: a semimetallic phase that occurs for half-integer s, and a metallic phase that contains a flat zero-energy band at integer s. These phases host a variety of interesting effects, such as a very rich anomalous quantum Hall effect and a remarkable multirefringent Klein tunneling. In addition, we show that these effects are directly related to the number of underlying Dirac-Weyl species and zero modes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗