Search NASA⌕ Search

Engineering topics

Luce, T

Publications and source records attributed to Luce, T.

Impact of ideal MHD stability limits on high-beta hybrid operation

Here, the hybrid scenario is a candidate for stationary high-fusion gain tokamak operation in ITER and DEMO. To obtain such performance, the energy confinement and the normalized pressure ${{\beta}_{N}}$ must be maximized, which requires operating near or above ideal MHD no-wall limits. New experimental findings show how these limits can affect hybrid operation. Even if hybrids are mainly limited by tearing modes, proximity to the no-wall limit leads to 3D field amplification that affects plasma profiles, e.g. rotation braking is observed in ASDEX Upgrade throughout the plasma and peaks in the core. As a result, even the small ASDEX Upgrade error fields are amplified and their effects become visible. To quantify such effects, ASDEX Upgrade measured the response to 3D fields applied by $8\times 2$ non-axisymmetric coils as ${{\beta}_{N}}$ approaches the no-wall limit. The full n = 1 response profile and poloidal structure were measured by a suite of diagnostics and compared with linear MHD simulations, revealing a characteristic feature of hybrids: the n = 1 response is due to a global, marginally-stable n = 1 kink characterized by a large m = 1, n = 1 core harmonic due to q min being just above 1. A helical core distortion of a few cm forms and affects various core quantities, including plasma rotation, electron and ion temperature, and intrinsic W density. In similar experiments, DIII-D also measured the effect of this helical core on the internal current profile, providing information useful to understanding of the physics of magnetic flux pumping, i.e. anomalous current redistribution by MHD modes that keeps ${{q}_{\text{min}}}>1$ . Thanks to flux pumping, a broad current profile is maintained in DIII-D even with large on-axis current drive, enabling fully non-inductive operation at high ${{\beta}_{N}}$ up to 3.5–4.

3D equilibrium↗

Dependence of Bootstrap Current, Stability, and Transport on the Safety Factor Profile in DIII-D Steady-State Scenario Discharges

Conclusions of this report are: (1) In our scans of q{sub min} and q{sub 95}, the bootstrap current fraction increased with q{sub 95} but did not continue to increase with q{sub min} above about 1.5 as expected by f{sub BS} {approx} q{beta}{sub N}; (2) With existing control tools, q{sub min} {approx} 1.5 appears optimal for maximizing bootstrap current if the calculated ideal wall limit can be reached (only narrowly more so than q{sub min} {approx} 1.1); (3) q{sub min} {approx} 2 discharges achieved lower {beta}{sub N} and calculated n = 1 {beta}{sub N} limits, had increased transport, lower density, lower temperature gradients, and as a result did not produce as much bootstrap current; (4) Highest f{sub BS} achieved at highest q{sub 95} (=6.8), but scan suggests lower q{sub 95} is required for more reactor relevant fusion gain G {approx} {beta}{sub N}H{sub 89}/q{sub 95}{sup 2}; (5) New tools (off-axis NBI, more ECCD) may allow access to higher {beta}{sub N} limits and higher bootstrap fractions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and Modelling of Tearing Mode Stability for Steady-State Plasmas in DIII-D

High-beta, quasi-steady state scenarios represent a fundamental step towards the performance required for future fusion reactors. In DIII-D steady-state scenario discharges, the normalized beta {beta}{sub N} {triple_bond} {beta}(%) {center_dot} a(m) {center_dot} B{sub T}(T)/I{sub p}(MA) (where {beta} is the ratio of the plasma pressure to the magnetic field pressure, {alpha} the plasma minor radius, B{sub T} the toroidal magnetic field and I{sub p} the plasma current) exceeds the no-wall ideal kink beta limit. The performance of this scenario is limited by the onset of an n = 1 tearing mode, which appears on the resistive evolution time-scale (1-2 s) at constant pressure and causes both a loss of confinement and a radial redistribution of the current density from which the available current drive sources cannot recover. It is routinely observed that the injection of electron cyclotron current drive (ECCD), with a broad deposition localized around {rho} {approx} 0.35, can prevent the mode from appearing. It must be noted that this is not a case of a direct stabilization due to the interaction with the mode's rational surface. These variations of the scenario are illustrated in Fig. 1, where the total injected power [neutral beam injection (NBI) and ECCD], {beta}{sub N} and the n = 1 magnetic perturbation at the outer wall are shown. In case (a), the onset of the n = 1 mode is observed when the EC power is not present or if it is stopped before the end of the high {beta} phase, whereas in case (b) the difference is pointed out between broad and narrow current deposition (with the narrow deposition case becoming unstable). The current density profile evolution and the MHD modes of several sets of significant discharges with and without ECCD (at different locations) have been analyzed, using motional Stark effect (MSE) spectroscopy measurements for the former and edge magnetic probes measurements, toroidal rotation profiles and fast electron cyclotron emission (ECE) data for the latter. One equilibrium based on EFIT reconstruction [1] with kinetic data has been perturbed by adding local current density at a specific radius, mimicking the application of EC waves, and the changes in the stability for a sequence of equilibria with the current perturbed at various radii, have been evaluated by means of the DCON [2], GATO [3] and PEST3 [4] codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Off-axis neutral beam current drive for advanced scenario development in DIII-D

Modification of the two existing DIII-D neutral beamlines is planned to allow vertical steering to provide off-axis neutral beam current drive (NBCD) peaked as far off-axis as half the plasma minor radius. New calculations for a downward-steered beam indicate strong current drive with good localization off-axis so long as the toroidal magnetic field, B-T, and the plasma current, I-p, point in the same direction. This is due to good alignment of neutral beam injection (NBI) with the local pitch of the magnetic field lines. This model has been tested experimentally on DIII-D by injecting equatorially mounted NBs into reduced size plasmas that are vertically displaced with respect to the vessel midplane. The existence of off-axis NBCD is evident in the changes seen in sawtooth behaviour in the internal inductance. By shifting the plasma upwards or downwards, or by changing the sign of the toroidal field, off-axis NBCD profiles measured with motional Stark effect data and internal loop voltage show a difference in amplitude (40-45%) consistent with differences predicted by the changed NBI alignment with respect to the helicity of the magnetic field lines. The effects of NBI direction relative to field line helicity can be large even in ITER: off-axis NBCD can be increased by more than 30% if the B-T direction is reversed. Modification of the DIII-D NB system will strongly support scenario development for ITER and future tokamaks as well as provide flexible scientific tools for understanding transport, energetic particles and heating and current drive.

Murakami, Masanori↗

Advances in the Physics Basis of the Hybrid Scenario on DIII-D

Recent experiments on DIII-D have extended the hybrid scenario towards the burning plasma regime by incorporating strong electron heating, low torque injection, and edge localized mode (ELM) suppression. Hybrid performance projecting to Q {ge} 10 on ITER at q{sub 95}=3.1 has been achieved in plasmas with reduced ion/electron temperature ratio or Mach number. Confinement is decreased relative to previous hybrid results, consistent with measurements of increased turbulence at low and intermediate wavenumbers. For the first time, large type-I ELMs have been completely suppressed in a hybrid plasma at q{sub 95}=3.6 by applying edge resonant magnetic perturbations (RMPs) with toroidal mode number n=3. Additionally, high performance hybrid and steady-state scenario operation has been demonstrated with reduced frequency of wall conditioning with a >95% graphite plasma-facing wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ITER Scenario Performance Simulations Assessing Control and Vertical Stability

In simulating reference scenarios proposed for ITER operation, we also explore performance of the poloidal field (PF) and central solenoid (CS) coil systems using a controller to maintain plasma shape and vertical stability during the discharge evolution. We employ a combination of techniques to evaluate system constraints and stability using time-dependent transport simulations of ITER discharges. We have begun the process of benchmarking these simulations with experiments on the DIII-D tokamak. Simulations include startup on the outside limiter, X-point formation and current ramp up to full power, plasma burn conditions at 15MA and 17MA, and ramp down at the end of the pulse. We also simulate perturbative events such as H-to-L back transitions. Our results indicate the viability of proposed ITER operating modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗