Application of the radiating divertor approach to innovative tokamak divertorconcepts
Abstract not provided
Engineering topics
Publications and source records attributed to Luce, T C.
Abstract not provided
Abstract not provided
Recent experiments on DIII-D have provided the first systematic data on the impact of the current profile on the transport and stability properties of high-performance, steady-state scenario plasmas. In a future tokamak, to achieve 100% noninductive conditions and produce net power, the current profile J must be sustained by a large fraction of bootstrap current J{sub BS}, which is nonlinearly coupled with the kinetic profiles. Systematic scans of q{sub min} and q{sub 95} were performed to determine empirically the best alignment of the noninductive currents with J and the variation of the transport properties with q. Transport analysis indicates that {chi}{sub e} and {chi}{sub i} are sensitive to the details of J in a way that makes the pressure profile peaking and J{sub BS} scale nonlinearly with both q and {beta} in the experiment. Drift wave stability analysis yields linear growth rates that do not reproduce experimental trends in {chi} with q{sub min} and q{sub 95}. At high beta, necessary to maximize f{sub BS}, the plasma duration is often limited by n=1 tearing modes, whose stability also depends on the J profile. Broadly deposited electron cyclotron (EC) current at mid-radius was found to supply part of the required noninductive current and to positively affect the tearing stability. The modes appear when J{sub EC} is turned off for stable cases and always appear when the EC deposition is shifted outwards. The variation in the EC scan results is consistent with PEST3 calculations, showing that the tearing stability becomes extremely sensitive to small perturbations of the equilibrium in wall-stabilized plasmas run close to the ideal MHD limit. These modeling results are being used to design new experiments with higher ideal and tearing limits. A new capability for off-axis neutral beam injection system will be used to explore higher q{sub min} scenarios and different current alignments.
Explore the source record for details and available documents.
Fast Waves (FWs) at 60 MHz and 90 MHz are used in DIII-D for central electron heating and current drive. Coupling of FWs to high-performance discharges is limited by low antenna loading in these regimes. To extend the application of high-power FWs to such regimes, methods of increasing the antenna loading in these regimes are needed. A systematic study of loading enhancement techniques has been carried out in DIII-D, including reduction of the antenna/plasma distance, gas puffing into the far scrape-off layer (SOL), and control of other parameters that affect the particle balance in the far SOL. Quantitative understanding of the physics of the loading resistance and its dependence on edge density profiles is demonstrated. The core FW heating efficiency appeared to be {approx}100% in the Advanced Inductive regime, consistent with the high first-pass direct electron absorption of {approx}75% that is predicted by the ray-tracing code GENRAY in this high electron beta regime.
High-power electron cyclotron (EC) waves are used to increase performance in several Advanced Tokamak (AT) regimes on DIII-D where there is a simultaneous need for high noninductive current and high beta. In the Quiescent High-confinement mode (QH-mode), a direct measurement of the electron cyclotron current drive (ECCD) profile is made using modulation techniques, and a trapped electron mode (TEM) dominated regime with core T{sub e}>T{sub i} is created. In the 'highq{sub min}' AT scenario, ECCD provides part of the off-axis noninductive current and helps to produce a tearing stable equilibrium. In the hybrid regime, strong central current drive from EC waves and other sources increases the noninductive current fraction to {approx_equal}100%. Surprisingly, the core safety factor remains above unity, meaning good alignment between the current drive profile and the desired plasma current profile is not necessary in this scenario.
Abstract not provided
Continuous operation of a tokamak for fusion energy has clear engineering advantages but requires conditions beyond those sufficient for a burning plasma. The fusion reactions and external sources must support both the pressure and the current equilibrium without inductive current drive, leading to demands on stability, confinement, current drive, and plasma-wall interactions that exceed those for pulsed tokamaks. These conditions have been met individually, and significant progress has been made in the past decade to realize scenarios where the required conditions are obtained simultaneously. Tokamaks are operated routinely without disruptions near pressure limits, as needed for steady-state operation. Fully noninductive sustainment with more than half of the current from intrinsic currents has been obtained for a resistive time with normalized pressure and confinement approaching those needed for steady-state conditions. One remaining challenge is handling the heat and particle fluxes expected in a steady-state tokamak without compromising the core plasma performance.
Recent progress on ITER steady-state (SS) scenario modelling by the ITPA-IOS group is reviewed. Code-to-code benchmarks as the IOS group's common activities for the two SS scenarios (weak shear scenario and internal transport barrier scenario) are discussed in terms of transport, kinetic profiles, and heating and current drive (CD) sources using various transport codes. Weak magnetic shear scenarios integrate the plasma core and edge by combining a theory-based transport model (GLF23) with scaled experimental boundary profiles. The edge profiles (at normalized radius rho = 0.8-1.0) are adopted from an edge-localized mode-averaged analysis of a DIII-D ITER demonstration discharge. A fully noninductive SS scenario is achieved with fusion gain Q = 4.3, noninductive fraction f(NI) = 100%, bootstrap current fraction f(BS) = 63% and normalized beta beta(N) = 2.7 at plasma current I(p) = 8MA and toroidal field B(T) = 5.3 T using ITER day-1 heating and CD capability. Substantial uncertainties come from outside the radius of setting the boundary conditions (rho = 0.8). The present simulation assumed that beta(N)(rho) at the top of the pedestal (rho = 0.91) is about 25% above the peeling-ballooning threshold. ITER will have a challenge to achieve the boundary, considering different operating conditions (T(e)/T(i) approximate to 1 and density peaking). Overall, the experimentally scaled edge is an optimistic side of the prediction. A number of SS scenarios with different heating and CD mixes in a wide range of conditions were explored by exploiting the weak-shear steady-state solution procedure with the GLF23 transport model and the scaled experimental edge. The results are also presented in the operation space for DT neutron power versus stationary burn pulse duration with assumed poloidal flux availability at the beginning of stationary burn, indicating that the long pulse operation goal (3000s) at I(p) = 9 MA is possible. Source calculations in these simulations have been revised for electron cyclotron current drive including parallel momentum conservation effects and for neutral beam current drive with finite orbit and magnetic pitch effects.
In order to maintain stationary values of the stored energy and the plasma current in a tokamak discharge with all of the current driven noninductively, the sum of the alpha-heating power and the power required to provide externally driven current must be equal to the power required to maintain the pressure against transport losses. In a study of high noninductive current fraction discharges in the DIII-D tokamak, it is shown that in the case of present-day tokamaks with no alpha-heating, adjustment of the toroidal field strength (B(T)) is a tool to obtain this balance between the required current drive and heating powers with other easily modifiable discharge parameters (beta(N), q(95), discharge shape, n(e)) fixed at values chosen to satisfy specific constraints. With all of the external power sources providing both heating and current drive, and beta(N) and q(95) fixed, the fraction of externally driven current scales with B(T) with little change in the bootstrap current fraction, thus allowing the noninductive current fraction to be adjusted.
Joint experiments investigating the off-axis neutral beam current drive (NBCD) capability to be utilized for advanced operation scenario development in ITER were conducted in four tokamaks (ASDEX Upgrade (AUG), DIII-D, JT-60U and MAST) through the international tokamak physics activity (ITPA). The following results were obtained in the joint experiments, where the toroidal field, B(t), covered 0.4-3.7 T, the plasma current, I(p), 0.5-1.2 MA, and the beam energy, E(b), 65-350 keV. A current profile broadened by off-axis NBCD was observed in MAST. In DIII-D and JT-60U, the NB driven current profile has been evaluated using motional Stark effect diagnostics and good agreement between the measured and calculated NB driven current profile was observed. In AUG (at low delta similar to 0.2) and DIII-D, introduction of a fast-ion diffusion coefficient of D(b) similar to 0.3-0.5 m(2) s(-1) in the calculation gave better agreement at high heating power (5 MW and 7.2 MW, respectively), suggesting anomalous transport of fast ions by turbulence. It was found through these ITPA joint experiments that NBCD related physics quantities reasonably agree with calculations (with D(b) = 0-0.5 m(2) s(-1)) in all devices when there is no magnetohydrodynamic (MHD) activity except ELMs. Proximity of measured off-axis beam driven current to the corresponding calculation with D(b) = 0 has been discussed for ITER in terms of a theoretically predicted scaling of fast-ion diffusion that depends on E(b)/T(e) for electrostatic turbulence or beta(t) for electromagnetic turbulence.
DIII-D is providing experimental evaluation of 4 leading ITER operational scenarios: the baseline scenario in ELMing H-mode, the advanced inductive scenario, the hybrid scenario, and the steady state scenario. The anticipated ITER shape, aspect ratio and value of I/{alpha}B were reproduced, with the size reduced by a factor of 3.7, while matching key performance targets for {beta}{sub N} and H{sub 98}. Since 2008, substantial experimental progress was made to improve the match to other expected ITER parameters for the baseline scenario. A lower density baseline discharge was developed with improved stationarity and density control to match the expected ITER edge pedestal collisionality ({nu}*{sub e} {approx} 0.1). Target values for {beta}{sub N} and H{sub 98} were maintained at lower collisionality (lower density) operation without loss in fusion performance but with significant change in ELM characteristics. The effects of lower plasma rotation were investigated by adding counter-neutral beam power, resulting in only a modest reduction in confinement. Robust preemptive stabilization of 2/1 NTMs was demonstrated for the first time using ECCD under ITER-like conditions. Data from these experiments were used extensively to test and develop theory and modeling for realistic ITER projection and for further development of its optimum scenarios in DIII-D. Theory-based modeling of core transport (TGLF) with an edge pedestal boundary condition provided by the EPED1 model reproduces T{sub e} and T{sub i} profiles reasonably well for the 4 ITER scenarios developed in DIII-D. Modeling of the baseline scenario for low and high rotation discharges indicates that a modest performance increase of {approx} 15% is needed to compensate for the expected lower rotation of ITER. Modeling of the steady-state scenario reproduces a strong dependence of confinement, stability, and noninductive fraction (f{sub NI}) on q{sub 95}, as found in the experimental I{sub p} scan, indicating that optimization of the q profile is critical to simultaneously achieving the f{sub NI} = 1 and Q = 5 goals. Extended integrated modeling is being developed to improve capability for ITER projection by including the experimental observations of density peaking, ELM characteristics, NTM suppression and coupled core-edge-SOL transport.
Abstract not provided
Understanding the dynamics of plasma startup and termination is important for present tokamaks and for predictive modeling of future burning plasma devices such as ITER. We report on experiments in the DIII-D tokamak that explore the plasma startup and rampdown phases and on the benchmarking of transport models. Key issues have been examined such as plasma initiation and burnthrough with limited inductive voltage and achieving flattop and maximum burn within the technical limits of coil systems and their actuators while maintaining the desired q profile. Successful rampdown requires scenarios consistent with technical limits, including controlled H-L transitions, while avoiding vertical instabilities, additional Ohmic transformer flux consumption, and density limit disruptions. Discharges were typically initiated with an inductive electric field typical of ITER, 0.3 V/m, most with second harmonic electron cyclotron assist. A fast framing camera was used during breakdown and burnthrough of low Z impurity charge states to study the formation physics. An improved 'large aperture' ITER startup scenario was developed, and aperture reduction in rampdown was found to be essential to avoid instabilities. Current evolution using neoclassical conductivity in the CORSICA code agrees with rampup experiments, but the prediction of the temperature and internal inductance evolution using the Coppi-Tang model for electron energy transport is not yet accurate enough to allow extrapolation to future devices.
The DIII-D programme has recently initiated an effort to provide suitably scaled experimental evaluations of four primary ITER operational scenarios. New and unique features of this work are that the plasmas incorporate essential features of the ITER scenarios and anticipated operating characteristics; e. g. the plasma cross-section, aspect ratio and value of I/aB of the DIII-D discharges match the ITER design, with size reduced by a factor of 3.7. Key aspects of all four scenarios, such as target values for beta(N) and H(98), have been replicated successfully on DIII-D, providing an improved and unified physics basis for transport and stability modelling, as well as for performance extrapolation to ITER. In all four scenarios, normalized performance equals or closely approaches that required to realize the physics and technology goals of ITER, and projections of the DIII-D discharges are consistent with ITER achieving its goals of >= 400MW of fusion power production and Q >= 10. These studies also address many of the key physics issues related to the ITER design, including the L-H transition power threshold, the size of edge localized modes, pedestal parameter scaling, the impact of tearing modes on confinement and disruptivity, beta limits and the required capabilities of the plasma control system. An example of direct influence on the ITER design from this work is a modification of the physics requirements for the poloidal field coil set at 15 MA, based on observations that the inductance in the baseline scenario case evolves to a value that lies outside the original ITER specification.
Neutral beam current drive (NBCD) experiments in DIII-D using vertically shifted plasmas to move the current drive away from the axis have clearly demonstrated robust off-axis NBCD. Time-dependent measurements of magnetic field pitch angles by the motional Stark effect diagnostic are used to obtain the evolution of the poloidal magnetic flux, which indicates a broad off-axis NBCD profile with a peak at about half the plasma minor radius. In most cases, the measured off-axis NBCD profile is consistent with calculations using an orbit-following Monte Carlo code for the beam ion slowing down including finite-orbit effects provided there is no large-scale magnetohydrodynamic activity such as Alfven eigenmodes modes or sawteeth. An alternative analysis method shows good agreement between the measured pitch angles and those from simulations using transport-equilibrium codes. Two-dimensional image of Doppler-shifted fast ion D{sub {alpha}} light emitted by neutralized energetic ions shows clear evidence for a hollow profile of beam ion density, consistent with classical beam ion slowing down. The magnitude of off-axis NBCD is sensitive to the alignment of the beam injection relative to the helical pitch of the magnetic field lines. If the signs of toroidal magnetic field and plasma current yield the proper helicity, both measurement and calculation indicate that the efficiency is as good as on-axis NBCD because the increased fraction of trapped electrons reduces the electron shielding of the injected ion current, in contrast with electron current drive schemes where the trapping of electrons degrades the efficiency. The measured off-axis NBCD increases approximately linearly with the injection power, although a modest amount of fast ion diffusion is needed to explain an observed difference in the NBCD profile between the measurement and the calculation at high injection power.
For a more detailed account of the results summarized here and for references, see C.T. Holcomb et al., Phys. Plasmas 16, 056116 (2009). Advanced tokamak research on DIII-D is focused on developing a high fusion gain, steady-state scenario that would eliminate or greatly reduce the demands on an inductive transformer in future machines. Steady-state operation requires the inductively driven current density (j{sub Ind}) be zero everywhere. Most of the total current I{sub p} is typically from self-driven bootstrap current, with the remainder driven by external noninductive sources, such as neutral beam and radiofrequency current drive. This paper describes an extension of the fully noninductive condition (f{sub NI} {approx} 100%) to {approx}0.7 current relaxation times that was achieved by a combination of more available ECCD and new scientific insights. The insights are an optimization of performance through variation of the plasma shape parameter known as squareness ({zeta}) and an optimization of divertor magnetic balance. These optimizations simultaneously improve stability, confinement, and density control. These are each essential for achieving fully noninductive operation.