Search NASASearch

Engineering topics

Luchik, T. S.

Publications and source records attributed to Luchik, T. S..

(abstract) Cryogenic Telescope Test Facility

An optical test Dewar is being constructed with the unique capability to test mirrors of diameter less than or equal to 1 m, f less than or equal to 6, at temperatures from 300 to 4.2 K with a ZYGO Mark IV interferometer. The design and performance of this facility will be presented.

cryogenic Dewar optical test mirrors liquid helium

Hot wire/film behavior in low-temperature gases

Commercially available hot wires/films were used to measure the velocities of evaporated hydrogen or helium gas during cryogenic mixing experiments. Hot wires were found to be too delicate to use in this harsh environment. Hot films were rugged enough to use at cryogenic temperatures even though they failed after a number of thermal cycles. Since the hot films have small aspect ratios, 13.4 and 20, they are quite sensitive to the thermal loading, Tw/Tg, even with a correction for the conduction end loss. In general, although the increase of the Nusselt number with Reynolds number at low temperatures was similar to that at room temperature, there was also a pronounced variation with Tw/Tg over the large range of 1.2 to 12 investigated.

Kwack, E. Y.

Acoustic composition sensor for cryogenic gas mixtures

An acoustic sensor useful for the determination of the composition of a gaseous binary mixture in cryogenic liquid spills has been characterized. One version of the instrument traps a known mixture of helium and nitrogen at ambient temperature in a tube which is interrogated by sonic pulses to determine the speed of sound and hence the composition. Experimental data shows that this sensor is quite accurate. The second version uses two unconfined microphones which sense sound pulses. Experimental data acquired during mixing when liquid nitrogen is poured into a vessel of gaseous helium is presented. Data during transient cooling of the tubular sensor containing nitrogen when the sensor is dipped into liquid nitrogen and during transient warm-up when the sensor is withdrawn are also presented. This sensor is being developed for use in the mixing of liquid cryogens with gas evolution in the simulation of liquid hydrogen/liquid oxygen explosion hazards.

Shakkottai, P.

Turbulent structure in low-concentration drag-reducing channel flows

A two-component laser-Doppler velocimeter was used to obtain simultaneous measurements of the velocity components parallel and normal to the wall in two fully developed well-mixed low-concentration drag-reducing channel flows and one turbulent channel flow. For the drag-reducing flows, the average time between bursts was found to increase. Although the basic structure of the fundamental momentum transport event is shown to be the same in these drag-reducing flows, the lower-threshold Reynolds-stress-producing motions were found to be damped, while the higher-threshold motions were not. It is suggested that some strong turbulent motions are needed to maintain extended polymer molecules, which produce a solution with properties that can damp lower threshold turbulence and thereby reduce viscous drag.

Luchik, T. S.