Challenges of Plasma Wakefield Accelerator Beams as Drivers for Free-Electron Lasers
Explore the source record for details and available documents.
Engineering topics
Publications and source records attributed to Lumpkin, Alex H..
Explore the source record for details and available documents.
Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high- Z gas-target dopants or by uncontrolled laser–plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators.
The FAST beamline is the injector for the planned Gamma-Ray Electron ENhanced Source (GREENS) program, which aims to achieve the demonstration and first application of a high-efficiency, high-average-power free-electron laser at 515 nm. FAST-GREENS requires high 5D peak brightness; transverse normalized projected emittances of 3 mm-mrad and a peak current of 600 A are the minimum beam requirements for the FEL to reach the 10% efficiency goal. In this work, studies of the low-energy section of the FAST beamline are presented toward these ends, including preliminary measurements of beam compression and beam emittance. An effort toward developing a high-fidelity simulation model that could be later optimized for FAST-GREENS is presented.
One of the predicted signatures of successful optical stochastic cooling (OSC) in the Fermilab Integrable Optics Test Accelerator (IOTA) ring is reduction of the bunch length. The IOTA OSC experiment is designed for a low nominal beam current (~0.1 microAmps of 100-MeV electrons) to reduce intrabeam scattering (IBS), and during cooling, OSC is expected to reduce the bunch length from ~200 ps to ~130 ps*. These equilibrium bunch lengths can be measured using a streak camera and the optical synchrotron radiation (OSR) generated in a ring dipole by the circulating beam. A similar measurement was previously performed at the Advanced Photon Source with a Hamamatsu C5680 synchroscan streak camera operating at 117.3 MHz**. In this case, synchronous summing of OSR resulted in a bunch length measurement of 276 ± 30 ps using only 57 electrons circulating at 425 MeV. At IOTA, an existing streak camera has been modified to operate at the 11th harmonic of the ring’s revolution frequency of 7.50 MHz and has been installed on an OSR port in support of the OSC experiments. The integrated system will have sufficient sensitivity and resolution for measuring the evolution and equilibrium values of the bunch length during OSC experiments.
Higher-order modes (HOMs) in superconducting rf cavities present problems for an electron bunch traversing the cavity in the form of long-range wakefields from previous bunches. These may dilute the emittance of the macropulse average, especially with low emittance beams at facilities such as the European X-ray Free-electron Laser (XFEL) and the upgraded Linac Coherent Light Source (LCLS-II). Here we present observations of HOMs driven by the beam at the Fermilab Accelerator Science and Technology (FAST) facility. The FAST facility features two independent TESLA-type cavities (CC1 and CC2) after a photocathode rf gun followed by an 8-cavity cryomodule. The HOM signals were acquired from cavities using bandpass filters of 1.75 ± 0.15 GHz, 2.5 ± 0.2 GHz, and 3.25 ± 0.2 GHz and recorded using an 8-GHz, 20 GSa/s oscilloscope. The frequency resolution obtained is sufficient to separate polarization components of many of the HOMs. These HOM signals were captured from CC1 and cavities 1 and 8 of the cryomodule for various initial trajectories through the cavities, and we observe correlations between trajectory, HOM signals, and which polarization component of a mode is affected.
The interest in controlling emittance dilution effects due to off-axis beam transport in accelerator cavities and the resulting dipolar modes is especially important for the facilities with lower emittance beams. The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of two single cavities after the photocathode rf gun followed by a cryomodule. The second capture cavity (CC2) was run 15 kHz off resonance and without rf power while a 25-MeV beam was injected into it. The beam centroid effects were tracked by 10 rf button BPMs with bunch-by-bunch position readout capability downstream in a 12-m drift. Possible LRW effects seemed to dominate our previously observed near-resonant HOM effects at mode 14 in this cavity. This mode also shifted in frequency compared to that of the tuned case based on direct measurements. Submacropulse vertical position slewing of 1400 microns at 11 m downstream was observed with a 125 pC/bunch, 50 bunches per macropulse, and 25-MeV beam. The y-position slew amplitudes as a function of z were also measured. Horizontal positions also showed a slew effect. Both are emittance-dilution effects which one wants to mitigate.
aExperiments were performed at The Fermilab Accelerator Science and Technology (FAST) facility to elucidate the effects of short-range wakefields (SRWs) in TESLA-type rf cavities. FAST has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. To investigate short-range wakefield effects, we have steered the beam to minimize the signals in the higher-order mode (HOM) detectors of CC1 and CC2 for a baseline, and then selected a vertical corrector to steer the beam off axis at an angle into CC1 or CC2. A Hamamatsu synchro-scan streak camera viewing a downstream OTR screen provided an image of y-t effects within the micropulses with ~10-micron spatial resolution and 2-ps temporal resolution. At 500 pC/b, 50 b, and 2 mrad off-axis steering into CC2, we observed an ~ 100-micron head-tail centroid shift in the streak camera image y(t)-profiles. This centroid shift value is consistent wit h a calculated short-range wakefield effect using ASTRA simulations.
The preservation of low emittance of electron beams during transport in the accelerating structures of large facilities is an ongoing challenge. In the cases of the TESLA-type superconducting rf cavities currently used in the European X-ray Free-electron Laser (XFEL) and the under-construction Linac Coherent Light Source upgrade (LCLS-II), off-axis beam transport may result in emittance dilution due to transverse long-range wakefields (LRWs) and short-range wakefields (SRW)***. To investigate such effects, experiments were performed at the Fermilab Accelerator Science and Technology (FAST) facility with its unique configuration of two TESLA-type cavities after the photocathode rf gun followed by an 8-cavity cryomodule CM). We generated beam trajectory changes with the H/V125 corrector set located 4 m upstream of the cryomodule. At 125 pC/bunch, 50 bunches, 25-MeV input, and 100-MeV exit energy, we observed for the first time submacropulse position slews of up to 500 microns at locations ~3 m after the CM and a centroid oscillation at a difference frequency of 240 kHz further downstream. Both are emittance-dilution effects which we mitigated with selective upstream beam steering.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A monocrystalline scintillator comprises a monocrystal and an optical plate wherein a first side of the monocrystal is adhered to the optical plate. The monocrystal comprises at least one of a rare earth garnet, a perovskite crystal, a rare-earth silicate, and a monocrystal oxysulphide. The scintillator assembly includes an adhesive adhering the optical plate to the first side of the monocrystal. The adhesive can comprise an ultra-high vacuum compatible adhesive. The adhesive is substantially transparent and has a refractive index matching the optical plate. The scintillator assembly can also include a reflective coating on the second side of the monocrystal. The monocrystalline scintillator assembly can be incorporated in a microchannel plate image intensifier tube to provide improved spatial resolution and temporal response.