Search NASA⌕ Search

Engineering topics

Luo, Mei

Publications and source records attributed to Luo, Mei.

Understanding particle size effect on fast-charging behavior of graphite anode using ultra-thin-layer electrodes

Extreme fast charging (≤ 15 min) of lithium-ion batteries is highly desirable to accelerate mass-market adoption of electric vehicles. However, significant capacity fading, as well as safety issues due to the lithium plating caused by the fast charging rate, limit its implementation. In this study, we investigated the fast-charging capability of graphite materials with various particle sizes. To eliminate the Li + ion concentration gradient effect across the thickness of the electrode, ultra-thin-layer graphite electrodes were developed to investigate the "real" fast-charging capability of graphite at the particle level. Electrochemical assessments as well as microscopic characterizations revealed that smaller particles exhibited superior fast-charging performance, featuring enhanced capacity reversibility, faster charging rate, and less lithium plating under the same fast-charging conditions. It is shown that small-particle graphite (mean radius of 3.3 μm) could withstand a 4C charge (to 80 % state-of-charge) without plating, with minimal plating occurring at 6C. Thicker particles exhibited plating at lower C-rates. Since the experimental data could not directly explain whether intra-particle diffusion limitations or interfacial reaction limitations dominated the plating mechanism, the pseudo-2-dimensional model was used to evaluate the most likely plating mechanism. The model suggested that particle-level diffusion is the dominant mechanism contributing to plating at high rates. Finally, this work provides comprehensive insights into the particle size effects on fast-charging capability, offering a better understanding of fast-charging behavior and valuable guidance for designing optimal electrode architecture for high-rate lithium-ion batteries.

25 ENERGY STORAGE↗

Interplay of intercalation dynamics and lithium plating in monolithic and architectured graphite anodes during fast charging

Fast charging of high-capacity anodes is challenging due to lithium plating reactions, which lead to poor cycling performance and safety concerns. Thus, accurate predictions of plating onset and an understanding of this electrochemical process are crucial for robust battery design. However, the most commonly used models, based on porous electrode theory (e.g., the pseudo-2D model), are notoriously difficult to calibrate due to their complexity, limiting their predictive power. This work studies the process of lithium plating during fast charging of (small-particle) graphite half-cells by measuring local reaction progression and plating behavior using optical operando techniques. These experiments employ a realistic 1D graphite electrode geometry with commercially-relevant mass loading charged at fast charge rates. It is demonstrated that the local reaction progression and plating onset can not only be predicted accurately with a p2D numerical model, but that these processes follow a simple scaling law. Remarkably, the entire reaction histories of different electrodes charged at different rates (e.g., 160 μm thickness at 0.5C, 111 μm at 1C or 66 μm at 4C) were observed to have self-similar intercalation profiles. It is demonstrated that plating onset is in turn governed by the reaction profile which explains why both processes exhibit the same scaling behavior. Finally, operando measurements of local reaction dynamics are conducted for the first time in electrodes with channeled architectures, quantitatively determining how channels affect reaction uniformity and plating onset. Together, these results reveal underlying simplicity in the complex electrochemical environment of fast charging and lithium plating, improving understanding of this process. These fundamental insights are broadly applicable for design processes, modeling and experimental evaluation of lithium ion batteries.

25 ENERGY STORAGE↗

A “Master Curve” Describing Reaction Inhomogeneity and Plating Onset during Fast-Charging of Graphite Electrodes

Lithium plating in porous graphite electrodes is a major limitation for fast charging. Theoretical evidence suggests plating during fast charging is largely due to inhomogeneous intercalation through the electrode thickness (caused by ionic/mass transfer limitations and inherent thermodynamic properties of the graphite material). Numerical and analytical predictions of plating onset during fast charging have been proposed but not compared directly with experiments. This work validates these model predictions against plating onset measurements via the “dOCV” method in graphite half-cells, for various electrode thicknesses and C-rates. Remarkably, it is shown that experimental and theoretical trends in plating onset (vs C-rate and electrode thickness) collapse to a single “master curve” using a nondimensional “reaction inhomogeneity” parameter. This observation supports the hypothesized reaction inhomogeneity mechanism for accelerating plating onset and provides practical guidance for electrode design. Furthermore, this work develops theory to quantify reaction inhomogeneity in situ directly from voltage V vs capacity Q data, using dQ / dV analysis. Here again, experiments and numerical predictions show good agreement, where peaks that correspond to LiC 6 correlate with plating onset. This work provides experimental validation of theoretical tools that can predict plating onset, aid electrode design, and give insight for plating onset mechanisms during fast charging.

25 ENERGY STORAGE↗

Fast charging of Li-ion cells: Effect of separator membranes and mapping of “safe lines” to avoid Li plating

An experimental method is introduced that uses microprobe Li/Cu reference electrodes to map "safe" charging regimes to avoid Li metal plating on graphite anodes at rates to 8C. With this method, a Li-ion cell closely approaches the Li plating condition but avoids descending into this regime. This "safe" approach is used to demonstrate effects of the microporous separator on Li plating in cells consisting of a layered nickel-manganese -cobalt oxide cathode and graphite anode. We argue that most of the difference in behaviors for different separators arises from time delayed Li + ion percolation through the membrane. In conclusion, our study suggests that explicitly treating kinetics of phase transitions in the lithiated graphite anode is essential for electrochemical models predicting "safe" lines for fast charging cells.

25 ENERGY STORAGE↗

Physicochemical Heterogeneity in Silicon Anodes from Cycled Lithium-Ion Cells

The severe capacity fade of lithium-ion cells with silicon-dominant anodes has hindered their widescale commercialization. In this work, we link cell capacity fade to the heterogeneous physicochemical evolution of silicon anodes during battery cycling. Through a multi-length scale characterization approach, we demonstrate that silicon particles near the anode surface react differently than those near the copper current collector. In particular, near the anode surface we find an amorphized wispy silicon encased in a highly fluorinated matrix of electrolyte-reduction products. In contrast, closer to the current collector, the silicon retains more of its initial morphology and structure, suggesting the presence of isolated particles. Here, the results show that accessibility of active silicon to lithium-ions varies across the anode matrix. Material and cell designs, which minimize electrode expansion resulting from the in-filling of pores with the solid electrolyte interphase (SEI), are needed to enhance anode homogeneity during the electrochemical cycling.

25 ENERGY STORAGE↗

Examining Effects of Negative to Positive Capacity Ratio in Three-Electrode Lithium-Ion Cells with Layered Oxide Cathode and Si Anode

The negative to positive electrode capacity ratio (N:P) is crucial for lithium-ion cell design because it affects both energy density and long-term performance. Here, the effect of N:P ratio on electrochemical performance has been investigated for NMC 532 /Si cells containing a reference electrode. By monitoring individual electrode potentials, depths of lithiation/delithiation at the anode and cathode could be determined. The superior performance of the higher N:P cell, including greater reversibility, better capacity retention and lower impedance rise, can be attributed to smaller volume changes in the silicon particles during electrochemical cycling.

25 ENERGY STORAGE↗

Concealed Cathode Degradation in Lithium-Ion Cells with a Ni-Rich Oxide

Difficulties with sourcing cobalt and the interest in increasing cell energy have motivated the development of Ni-rich oxide materials for lithium-ion battery cathodes. Despite the intense research on the topic, there is limited information available on the long-term performance of novel cathode formulations. Here, we evaluate the stability of LiNi 0.9 Mn 0.05 Co 0.05 O 2 in full-cells tested for over five months, assessing how cycling, voltage and electrolyte additives impact cathode aging. We use differential voltage analysis to extract insights about the cathode from the full-cell data and identify the isolation of cathode particles in the delithiated (charged) state as a relevant mode of aging. Importantly, this particular mechanism of cathode aging does not cause immediate cell capacity fade, causing the simple analysis of cell capacity retention to overestimate the cathode stability under the investigated conditions. So, our observations serve as cautionary tale indicating that careful analysis of data from extended testing may be required for assessing the performance of Ni-rich cathodes and for evaluating how these materials are affected by electrolyte additives.

25 ENERGY STORAGE↗

Development and evaluation of a Novel RT‐PCR system for reliable and rapid SARS‐CoV ‐2 screening of blood donations

Abstract Background The ongoing outbreak of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) has caused great global concerns. In contrast to SARS, some SARS‐CoV‐2–infected people can be asymptomatic or have only mild nonspecific symptoms. Furthermore, there is evidence that SARS‐CoV‐2 may be infectious during an asymptomatic incubation period. With the discovery that SARS‐CoV‐2 can be detected in plasma or serum, blood safety is worthy of consideration. Study Design and Methods We developed a nucleic acid test (NAT) screening system for SARS‐CoV‐2 targeting nucleocapsid protein (N) and open reading frame 1ab (ORF 1ab) gene that could screen 5076 samples every 24 hours. The 2019 novel coronavirus RNA standard was used to evaluate linearity of standard curves. Diagnostic sensitivity and reproducibility were evaluated using artificial SARS‐CoV‐2. Specificity was evaluated with 61 other respiratory pathogens. Diagnostic performance was evaluated by testing two sputum and nine oropharyngeal swab specimens. The reverse transcription polymerase chain reaction (RT‐PCR) assay was used to screen SARS‐CoV‐2 RNA in blood donor specimens collected during the outbreak of SARS‐CoV‐2 in Chengdu. Results Limits of detection of the SARS‐CoV‐2 RT‐PCR assay for N and ORF 1ab gene were 12.5 and 27.58 copies/mL, respectively. Intra‐assay and interassay for the SARS‐CoV‐2 RT‐PCR assay based on cycle threshold were acceptably low. No cross‐reactivity was observed with other respiratory virus and bacterial isolates. The overall agreement value between the SARS‐CoV‐2 RT‐PCR assay and clinical diagnostic results was 100%. A total of 16 287 blood specimens collected from blood donors during SARS‐CoV‐2 surveillance were tested negative. Conclusions A high‐throughput NAT screening system was developed for SARS‐CoV‐2 screening of blood donations during the outbreak of SARS‐CoV‐2.

Li, Meng↗