Luttman, Aaron B.

Publications and source records attributed to Luttman, Aaron B..

Reduction of Radiographic Spot Size with Dual Diameter Sub-mm Rods

Among the most dominant factors in x-ray radiographic image resolution is the radiographic spot size, which is primarily a function of the physical extent of the x-ray source, so the most marked improvements in image resolution come from modifying the pulse power driver’s diode configuration to reduce that extent. The smaller the size of the x-ray spot, the higher the image resolution potential. The U.S. Naval Research Laboratory’s Mercury pulsed power accelerator has been configured with a rod-pinch diode, and recent measurements were conducted to demonstrate the impact of anode rod geometry on x-ray spot size. The “standard” anode rod is a 0.75 mm diameter cylinder that is tapered down to 0.25 mm over a length of 5 mm, and, in this study, it was replaced by rods with a sharp step between their two diameters, rather than a taper. The effect on spot size was assessed by analyzing the edge and line spread functions calculated from high-mag rolled edge and pinhole camera images. For certain diameter pairs, a reduction in radiographic spot size is observed. In addition, the dual-diameter rods have provided unique insight into the electron-anode coupling dynamics that are at play in all diodes of this type.

X-ray radiography, spot size↗

Tomographic Reconstruction of the Neutron Time-Energy Spectrum from a Dense Plasma Focus

A dense plasma focus (DPF) nuclear fusion device is an attractive pulsed neutron source in many applications, due to its relatively large neutron yield, produced in a short time duration. In order to design a DPF that generates neutrons within a specified time profile, or generates a neutron energy spectrum with specific properties, it is necessary to be able to characterize and model the results of the fusion process releasing the neutrons. The time-energy spectrum of fusion neutrons is an ideal quantity to use to validate multiphysics codes that simulate the pinch and fusion processes, because it is a quantity that requires the physics of each of the stages leading up to and ending in the fusion reaction to be simulated correctly. In particular, since DPF fusion neutrons are not monoenergetic -- and there can often be several fusion pinches creating neutrons -- a computer simulation matching high quality neutron spectrum measurements provides great confidence in the fidelity of the simulation. In order to make such a comparison, it is first necessary to have quality measurements from which to infer the spectrum. In this work we pose neutron spectroscopy as the classical tomographic inverse problem from neutron time of flight data at multiple distances, but enhanced by using an additional measurement of the time profile of the fusion pinch near its source and by using detector pairs set up in a geometry that allows for scatter background subtraction. The detector pairs enhance the quality of the time of flight measurements, and the additional constraint posed by the measured time profile allows for reconstructions discretized as finely as the time measurements and in energy as finely as 100 keV, without the problem being underdetermined. We present results from a Deuterium-fueled DPF at the U.S. Department of Energy's Nevada National Security Site and show that we can infer the time-energy spectrum from our measurements for both single and multi-pinch fusion reactions with equal fidelity.

Catenacci, Jared↗