Search NASA⌕ Search

Engineering topics

Lutz, S S

Publications and source records attributed to Lutz, S S.

Design and Assembly of a Telecentric Zoom Lens for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. The rod-pinch x-ray diode produces a point source measuring 1 mm diameter. The target object is placed 1.5 m from the x-ray source, with a large LYSO scintillator at 2.4 m. Different-sized objects are imploded within a containment vessel. A large pellicle deflects the scintillator light out of the x-ray path into an 11-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of test objects of different sizes, the scintillator and zoom lens can be translated along the x-ray axis. Zoom lens magnifications are changed when different-sized scintillators and recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one lens element and allowing all lenses to move, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 550 nm. All lenses are coated with anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, and the CCD camera move during zoom operations. One doublet has XY compensation. The first three lenses use fused silica for radiation damage control. The 60 lb of glass inside the 340 lb mechanical structure is oriented vertically.

42 ENGINEERING↗

Summary of the first neutron image data collected at the National Ignition Facility

A summary of data and results from the first neutron images produced by the National Ignition Facility (NIF), Lawrence Livermore National Laboratory, Livermore, CA, USA are presented. An overview of the neutron imaging technique is presented, as well as a synopsis of the data collected and measurements made to date. Data form directly driven, DT filled microballoons, as well as, indirectly driven, cryogenically layered ignition experiments are presented. The data presented show that the primary cores from directly driven implosions are approximately twice as large, 64 {+-} 3 {mu}m, as indirect cores 25 {+-} 4 and 29 {+-} 4 {mu}m and more asymmetric, P2/P0 = 47% vs. -14% and 7%. Further, comparison with the size and shape of X-ray image data on the same implosions show good agreement, indicating X-ray emission is dominated by the hot regions of the implosion.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of the First Neutron Image Data Collected at the National Ignition Facility

A summary of data and results from the first neutron images produced by the National Ignition Facility (NIF), Lawrence Livermore National Laboratory, Livermore, CA, USA are presented. An overview of the neutron imaging technique is presented, as well as a synopsis of the data collected and measurements made to date. Data form directly driven, DT filled microballoons, as well as, indirectly driven, cryogenically layered ignition experiments are presented. The data presented show that the primary cores from directly driven implosions are approximately twice as large, 64 +/- 3 um, as indirect cores (25 +/- 4 and 29 +/- 4 um and more asymmetric, P2/P0 = 47% vs. -14% and -7%. Further, comparison with the size and shape of X-ray image data from on the same implosions show good agreement, indicating X-ray emission is dominated by the hot regions of the implosion. This work was performed for the U.S. Department of Energy, National Nuclear Security Administration and by the National Ignition Campaign partners; Lawrence Livermore National Laboratory (LLNL), University of Rochester -Laboratory for Laser Energetics (LLE), General Atomics(GA), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL). Other contributors include Lawrence Berkeley National Laboratory (LBNL), Massachusetts Institute of Technology (MIT), Atomic Weapons Establishment (AWE), England, and Commissariat `a l’ ´ Energie Atomique (CEA), France.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Neutron Imaging System Fielded at the National Ignition Facility

We have fielded a neutron imaging system at the National Ignition Facility to collect images of fusion neutrons produced in the implosion of inertial confinement fusion experiments and scattered neutrons from (n, n') reactions of the source neutrons in the surrounding dense material. A description of the neutron imaging system will be presented, including the pinhole array aperture, the line-of-sight collimation, the scintillator-based detection system and the alignment systems and methods. Discussion of the alignment and resolution of the system will be presented. We will also discuss future improvements to the system hardware.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

X-ray Diode Preparation

A rod pinch x-ray diode assembly culminates in a coaxial anode cathode arrangement where a small anode rod extends through the aperture of a cathode plate. Shotto- shot repeatability in rod placement, and thus x-ray source spot position, has potential to positively affect radiographic image quality. Thus, how to both control and measure, according to a Cartesian coordinate system, anode rod tip displacement (x, y) (off the beam line-of-sight retical) and also anode rod tip extension (z) (along the line-of-sight center line) become salient issues relative to radiographic image set utility. To address these issues both hardware fabrication and x-ray diode assembly methods were reviewed, and additional controls were introduced. A photogrammetric procedure was developed to quantify anode rod tip position in situ. Computer models and mock-up assemblies with precision fiducials were produced to validate this procedure. Therefore, both anode rod tip displacement and anode rod tip extension parameters were successfully controlled. Rod position was measured and met the required specifications: (1) radial displacement <0.25 mm and (2) axial placement of ±0.25 mm. We demonstrated that precision control and measurement of large scale components is achievable in a pulse power system (i.e., hardware and operations). Correlations with diode performance and radiography are presented.

42 ENGINEERING↗