High-energy radiographic imaging performance of LYSO

Here, a comprehensive comparison of the dominant sources of radiation-induced blur for radiographic imaging system performance is made. End-point energies of 6, 10, 15, and 20 MeV bremsstrahlung photon radiation produced at the Los Alamos National Laboratory Microtron facility were used to examine the performance of large-panel cerium-doped lutetium yttrium silicon oxide (LYSO:Ce) scintillators 3, 5 and 10 mm thick. The system resolution was measured and compared between the various end-point energies and scintillator thicknesses. Contrary to expectations, it is found that there was only a minor dependence of system resolution on scintillator thickness or beam end-point energy. This indicates that increased scintillator thickness does not have a dramatic effect on system performance. The data are then compared to Geant4 simulations to assess contributions to the system performance through the examination of modulation transfer functions. It was determined that the low-frequency response of the system is dominated by the radiation-induced signal, while the higher-frequency response of the system is dominated by the optical imaging of the scintillation emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Disentangling Radiographic Contributions

Presentation describes research program and goal to understand all large radiographic contributions for a given image and assess if quantitative predictions can be made once contributions are understood, with current focus understanding scintillator response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flash Radiography Studies with Microcolumnar CsI

There is growing interest in using low-energy flash x-ray sources in radiographic applications to provide high-contrast images of low-density objects. Due to the low-energy nature of the detected photons, thin bright scintillators are desired. In order to pursue an optimum radiographic system, experimental studies have been performed of the static imaging properties of thin microcolumnar CsI using a Platts x-ray source. The Platts source is a nominally 300 keV endpoint rod pinch diode x-ray source with a ~35 ns pulse time. The source was used to measure the imaging properties of microcolumnar CsI with various thicknesses and backings. The experimental setup was modeled in GEANT4, and the images were simulated to estimate system performance. Taking into account the source photon production, radiation transport, and system optical performance, an accurate assessment of the detection system can be deduced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗