RHIC Run 22, 9 o'clock, a Snake in the Blue

The simulations detailed in this Tech. Note were aimed at determining new RHIC Blue 9 o’clock snake coil current and local closed orbit bump settings, together with updated - optimized - 3 o’clock snake settings, in order to recover from power supply dips which, early in the run (December 2021), caused the failure of 9 o’clock snake’s second coil in a first occurrence, and of its fourth coil in addition in a second occurrence, leaving the poor animal with just its coils 1 and 3. Documentation from a similar incident in Yellow in 2003 could be leaned on and allowed to promptly figure various necessary measures for swift recovery using the 9 o’clock Blue snake coils which survived the dip. Reference reports in particular that, in this 2003 incident, “[it was] decided to run the [failed] snake as a 88% partial snake while keeping the angles between the two snakes as 90° [...]. In general, the polarization level was not as good as Blue ring”. By contrast in this Run 22 incident, thorough simulations using the snake OPERA field maps helped determine new settings of the handicapped, 2-coil, Blue ring 9 o’clock snake currents and local closed orbit bump, and concurrently determine slight adjustment of the 3 o’clock snake currents, which allowed recovering full polarization at store, as good as could be expected from normal operation - even better over extended periods than in the Yellow ring.

43 PARTICLE ACCELERATORS↗

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

43 PARTICLE ACCELERATORS↗